用脐带血替代新生儿血液测量血清白蛋白和免疫球蛋白 G 水平。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Toshihiko Ikuta, Sota Iwatani, Seiji Yoshimoto
{"title":"用脐带血替代新生儿血液测量血清白蛋白和免疫球蛋白 G 水平。","authors":"Toshihiko Ikuta, Sota Iwatani, Seiji Yoshimoto","doi":"10.1093/ajcp/aqae089","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>In this study, we investigated the clinical feasibility of using umbilical cord blood as an alternative to neonatal blood for measuring serum albumin and immunoglobulin G (IgG) levels in newborns, including preterm newborns.</p><p><strong>Methods: </strong>Serum levels of albumin and IgG were measured in cord and neonatal blood from singleton newborns. We analyzed correlations and systematic errors between cord and neonatal blood measurements, stratifying the results for very preterm newborns (VPNs) born at a gestational age of less than 32 weeks and non-VPNs born at a gestational age of 32 weeks or later.</p><p><strong>Results: </strong>Among all 494 newborns (78 VPNs and 416 non-VPNs), serum albumin and IgG levels were determined for 95.7% and 88.7% of them, respectively. Strong correlations between cord and neonatal blood were observed for the serum albumin and IgG levels (rs = 0.864 and 0.966, respectively). Moreover, the measurement errors between cord and neonatal blood were small for all newborns (0.2 g/dL and 65 mg/dL, respectively). These findings were consistent with both VPNs and non-VPNs.</p><p><strong>Conclusions: </strong>Umbilical cord blood is a suitable substitute for neonatal blood in measuring serum albumin and IgG levels in newborns, even in premature newborns.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Umbilical cord blood as a substitute for neonatal blood in measuring serum albumin and immunoglobulin G levels.\",\"authors\":\"Toshihiko Ikuta, Sota Iwatani, Seiji Yoshimoto\",\"doi\":\"10.1093/ajcp/aqae089\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>In this study, we investigated the clinical feasibility of using umbilical cord blood as an alternative to neonatal blood for measuring serum albumin and immunoglobulin G (IgG) levels in newborns, including preterm newborns.</p><p><strong>Methods: </strong>Serum levels of albumin and IgG were measured in cord and neonatal blood from singleton newborns. We analyzed correlations and systematic errors between cord and neonatal blood measurements, stratifying the results for very preterm newborns (VPNs) born at a gestational age of less than 32 weeks and non-VPNs born at a gestational age of 32 weeks or later.</p><p><strong>Results: </strong>Among all 494 newborns (78 VPNs and 416 non-VPNs), serum albumin and IgG levels were determined for 95.7% and 88.7% of them, respectively. Strong correlations between cord and neonatal blood were observed for the serum albumin and IgG levels (rs = 0.864 and 0.966, respectively). Moreover, the measurement errors between cord and neonatal blood were small for all newborns (0.2 g/dL and 65 mg/dL, respectively). These findings were consistent with both VPNs and non-VPNs.</p><p><strong>Conclusions: </strong>Umbilical cord blood is a suitable substitute for neonatal blood in measuring serum albumin and IgG levels in newborns, even in premature newborns.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-07-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1093/ajcp/aqae089\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1093/ajcp/aqae089","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究探讨了用脐带血替代新生儿血液测量新生儿(包括早产儿)血清白蛋白和免疫球蛋白 G(IgG)水平的临床可行性:方法: 我们测量了单胎新生儿脐带血和新生儿血中的血清白蛋白和 IgG 水平。我们分析了脐带血和新生儿血液测量结果之间的相关性和系统误差,并对胎龄小于 32 周的极早产新生儿(VPN)和胎龄在 32 周或 32 周以上的非早产新生儿进行了分层:在所有 494 名新生儿(78 名 VPN 和 416 名非 VPN)中,分别有 95.7% 和 88.7% 的新生儿检测到血清白蛋白和 IgG 水平。脐带血和新生儿血液中的血清白蛋白和 IgG 水平之间存在很强的相关性(rs = 0.864 和 0.966)。此外,所有新生儿的脐带血和新生儿血的测量误差都很小(分别为 0.2 克/分升和 65 毫克/分升)。这些结果与 VPN 和非 VPN 一致:结论:在测量新生儿血清白蛋白和 IgG 水平时,脐带血是新生儿血液的合适替代品,早产儿也不例外。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Umbilical cord blood as a substitute for neonatal blood in measuring serum albumin and immunoglobulin G levels.

Objectives: In this study, we investigated the clinical feasibility of using umbilical cord blood as an alternative to neonatal blood for measuring serum albumin and immunoglobulin G (IgG) levels in newborns, including preterm newborns.

Methods: Serum levels of albumin and IgG were measured in cord and neonatal blood from singleton newborns. We analyzed correlations and systematic errors between cord and neonatal blood measurements, stratifying the results for very preterm newborns (VPNs) born at a gestational age of less than 32 weeks and non-VPNs born at a gestational age of 32 weeks or later.

Results: Among all 494 newborns (78 VPNs and 416 non-VPNs), serum albumin and IgG levels were determined for 95.7% and 88.7% of them, respectively. Strong correlations between cord and neonatal blood were observed for the serum albumin and IgG levels (rs = 0.864 and 0.966, respectively). Moreover, the measurement errors between cord and neonatal blood were small for all newborns (0.2 g/dL and 65 mg/dL, respectively). These findings were consistent with both VPNs and non-VPNs.

Conclusions: Umbilical cord blood is a suitable substitute for neonatal blood in measuring serum albumin and IgG levels in newborns, even in premature newborns.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信