{"title":"基于实验室间比较(ILCs)的电离辐射测量可靠性国家计划:ILC n°2 \"放射性药物活动","authors":"","doi":"10.1016/j.apradiso.2024.111449","DOIUrl":null,"url":null,"abstract":"<div><p>A national Inter-Laboratory Comparisons (ILCs) programme was organized in Italy in 2022 by the Italian National Institute of Ionizing Radiation Metrology (INMRI), belonging to ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), under the auspices of the Ministry of Enterprises and Made in Italy (Mimit ex MiSe). Within this ILCs programme, six inter-laboratory comparisons were organized, including the ILC-2 which focused on activity measurements carried out with radionuclide calibrators commonly used in the nuclear medicine departments of the participants.</p><p>The focus was on three short-lived radionuclides - <sup>99m</sup>Tc, <sup>18</sup>F, <sup>177</sup>Lu - commonly employed in nuclear medicine for both diagnostic and therapeutic purposes. All presented results were compared with the reference values provided by ENEA-INMRI to ensure the traceability of measurements to the national primary activity standards. The observed deviation from the reference values of the measured activity were mainly within <span><math><mrow><mo>±</mo></mrow></math></span> 10% (100% for <sup>18</sup>F, 91.7% for <sup>99m</sup>Tc, 100% for <sup>177</sup>Lu). The <em>E</em><sub><em>n</em></sub> statistical estimator was used to assess the participants’ ability to estimate uncertainty in the provided activity values. The obtained values revealed that, in certain instances, the involved laboratories did not achieve the correct results for <em>E</em><sub><em>n</em></sub> (with failure rates of 22.7%, 16.7%, 12.5% for <sup>18</sup>F, <sup>99m</sup>Tc, <sup>177</sup>Lu, respectively), despite deviations from the reference values falling within the <span><math><mrow><mo>±</mo></mrow></math></span> 10%. The aim of ILC-2 was to harmonize the activity measurements in the country within the field of nuclear medicine for the specific radionuclides studied and enhance the measurement capabilities of the participants.</p></div>","PeriodicalId":8096,"journal":{"name":"Applied Radiation and Isotopes","volume":null,"pages":null},"PeriodicalIF":1.6000,"publicationDate":"2024-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S096980432400277X/pdfft?md5=53c0d743bf0d3a8e3a88d4a1a46a0bf7&pid=1-s2.0-S096980432400277X-main.pdf","citationCount":"0","resultStr":"{\"title\":\"National programme for the reliability of ionizing radiation measurements based on inter-laboratory comparisons (ILCs): ILC n°2 ‘radiopharmaceutical activities’\",\"authors\":\"\",\"doi\":\"10.1016/j.apradiso.2024.111449\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A national Inter-Laboratory Comparisons (ILCs) programme was organized in Italy in 2022 by the Italian National Institute of Ionizing Radiation Metrology (INMRI), belonging to ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), under the auspices of the Ministry of Enterprises and Made in Italy (Mimit ex MiSe). Within this ILCs programme, six inter-laboratory comparisons were organized, including the ILC-2 which focused on activity measurements carried out with radionuclide calibrators commonly used in the nuclear medicine departments of the participants.</p><p>The focus was on three short-lived radionuclides - <sup>99m</sup>Tc, <sup>18</sup>F, <sup>177</sup>Lu - commonly employed in nuclear medicine for both diagnostic and therapeutic purposes. All presented results were compared with the reference values provided by ENEA-INMRI to ensure the traceability of measurements to the national primary activity standards. The observed deviation from the reference values of the measured activity were mainly within <span><math><mrow><mo>±</mo></mrow></math></span> 10% (100% for <sup>18</sup>F, 91.7% for <sup>99m</sup>Tc, 100% for <sup>177</sup>Lu). The <em>E</em><sub><em>n</em></sub> statistical estimator was used to assess the participants’ ability to estimate uncertainty in the provided activity values. The obtained values revealed that, in certain instances, the involved laboratories did not achieve the correct results for <em>E</em><sub><em>n</em></sub> (with failure rates of 22.7%, 16.7%, 12.5% for <sup>18</sup>F, <sup>99m</sup>Tc, <sup>177</sup>Lu, respectively), despite deviations from the reference values falling within the <span><math><mrow><mo>±</mo></mrow></math></span> 10%. The aim of ILC-2 was to harmonize the activity measurements in the country within the field of nuclear medicine for the specific radionuclides studied and enhance the measurement capabilities of the participants.</p></div>\",\"PeriodicalId\":8096,\"journal\":{\"name\":\"Applied Radiation and Isotopes\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S096980432400277X/pdfft?md5=53c0d743bf0d3a8e3a88d4a1a46a0bf7&pid=1-s2.0-S096980432400277X-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied Radiation and Isotopes\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S096980432400277X\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, INORGANIC & NUCLEAR\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Radiation and Isotopes","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S096980432400277X","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, INORGANIC & NUCLEAR","Score":null,"Total":0}
引用次数: 0

摘要

意大利国家电离辐射计量研究所(INMRI)隶属于意大利国家新技术、能源和可持续经济发展局(ENEA),在意大利企业和制造部(Mimit ex MiSe)的支持下,于2022年在意大利组织了一项国家实验室间比对计划(ILCs)。在该 ILCs 计划内,共组织了六次实验室间比对,其中 ILC-2 比对的重点是使用参与方核医学部门常用的放射性核素校准器进行的放射性活度测量,重点是三种短寿命放射性核素--99mTc、18F 和 177Lu --常用于核医学诊断和治疗。所有展示的结果都与 ENEA-INMRI 提供的参考值进行了比较,以确保测量结果可追溯到国家一级放射性活度标准。观察到的测量放射性活度与参考值的偏差主要在±10%以内(18F为100%,99mTc为91.7%,177Lu为100%)。En 统计估算器用于评估参与者估算所提供放射性活度值的不确定性的能力。所获得的数值显示,在某些情况下,尽管与参考值的偏差在±10%以内,但相关实验室并未获得正确的 En 结果(18F、99mTc 和 177Lu 的失败率分别为 22.7%、16.7% 和 12.5%)。ILC-2 的目的是协调国内核医学领域对所研究的特定放射性核素的放射性活度测量,并提高参与者的测量能力。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
National programme for the reliability of ionizing radiation measurements based on inter-laboratory comparisons (ILCs): ILC n°2 ‘radiopharmaceutical activities’

A national Inter-Laboratory Comparisons (ILCs) programme was organized in Italy in 2022 by the Italian National Institute of Ionizing Radiation Metrology (INMRI), belonging to ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), under the auspices of the Ministry of Enterprises and Made in Italy (Mimit ex MiSe). Within this ILCs programme, six inter-laboratory comparisons were organized, including the ILC-2 which focused on activity measurements carried out with radionuclide calibrators commonly used in the nuclear medicine departments of the participants.

The focus was on three short-lived radionuclides - 99mTc, 18F, 177Lu - commonly employed in nuclear medicine for both diagnostic and therapeutic purposes. All presented results were compared with the reference values provided by ENEA-INMRI to ensure the traceability of measurements to the national primary activity standards. The observed deviation from the reference values of the measured activity were mainly within ± 10% (100% for 18F, 91.7% for 99mTc, 100% for 177Lu). The En statistical estimator was used to assess the participants’ ability to estimate uncertainty in the provided activity values. The obtained values revealed that, in certain instances, the involved laboratories did not achieve the correct results for En (with failure rates of 22.7%, 16.7%, 12.5% for 18F, 99mTc, 177Lu, respectively), despite deviations from the reference values falling within the ± 10%. The aim of ILC-2 was to harmonize the activity measurements in the country within the field of nuclear medicine for the specific radionuclides studied and enhance the measurement capabilities of the participants.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied Radiation and Isotopes
Applied Radiation and Isotopes 工程技术-核科学技术
CiteScore
3.00
自引率
12.50%
发文量
406
审稿时长
13.5 months
期刊介绍: Applied Radiation and Isotopes provides a high quality medium for the publication of substantial, original and scientific and technological papers on the development and peaceful application of nuclear, radiation and radionuclide techniques in chemistry, physics, biochemistry, biology, medicine, security, engineering and in the earth, planetary and environmental sciences, all including dosimetry. Nuclear techniques are defined in the broadest sense and both experimental and theoretical papers are welcome. They include the development and use of α- and β-particles, X-rays and γ-rays, neutrons and other nuclear particles and radiations from all sources, including radionuclides, synchrotron sources, cyclotrons and reactors and from the natural environment. The journal aims to publish papers with significance to an international audience, containing substantial novelty and scientific impact. The Editors reserve the rights to reject, with or without external review, papers that do not meet these criteria. Papers dealing with radiation processing, i.e., where radiation is used to bring about a biological, chemical or physical change in a material, should be directed to our sister journal Radiation Physics and Chemistry.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信