测试时间会影响色觉缺陷受试者的范斯沃思 D15 测试结果,但不会影响未受试者的测试结果。

IF 1.6 4区 医学 Q3 OPHTHALMOLOGY
Optometry and Vision Science Pub Date : 2024-07-01 Epub Date: 2024-07-22 DOI:10.1097/OPX.0000000000002159
Anne Arah Cho, Jason S Ng
{"title":"测试时间会影响色觉缺陷受试者的范斯沃思 D15 测试结果,但不会影响未受试者的测试结果。","authors":"Anne Arah Cho, Jason S Ng","doi":"10.1097/OPX.0000000000002159","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Imposing a time limit on the Farnsworth D15 test may prevent patients from compromising the test.</p><p><strong>Purpose: </strong>This study aimed to investigate the effect of test time on the Farnsworth D15 color vision test in unpracticed and practiced subjects and determine an optimal test time.</p><p><strong>Methods: </strong>Twenty-one subjects (mean/standard deviation age, 33.1/9.3 years) with a range of congenital color vision deficiency participated in the study. Pseudoisochromatic plate screening, Farnsworth D15, and anomaloscope testing were performed for classification purposes. At each of 2 visits, 10 trials of the Farnsworth D15 were performed with a range in test times from 30 seconds to 10 minutes. Between visits, subjects practiced the test. Major crossovers were used as the outcome measure. A repeated-measures analysis of variance compared the scores across trials. Post hoc Dunnett's testing analyzed the pairwise data.</p><p><strong>Results: </strong>Although no significant difference in the mean number of major crossovers was found across the 10 trials for the first visit ( F (9, 180) = 1.30, p=0.24), a significant difference was found for the second visit ( F (9, 180) = 4.77, p<0.001). The range of mean number of major crossovers for the second visit was 1.71 to 5.1, with the 30-second trial resulting in the largest number of major crossovers and the longest trial resulting in the smallest number of major crossovers. Analysis showed that a 2-minute time limit resulted in a Farnsworth D15 outcome that would be expected based on the anomaloscope for a majority of subjects.</p><p><strong>Conclusions: </strong>In this study, test time was found to affect performance in practiced subjects but not in unpracticed subjects. Based on this study, we recommend enforcing a time limit of 2 minutes to discourage those who try to pass the Farnsworth D15 through practice. Additional measures, such as recording patient behavior, can also be taken.</p>","PeriodicalId":19649,"journal":{"name":"Optometry and Vision Science","volume":" ","pages":"477-484"},"PeriodicalIF":1.6000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Test time affects Farnsworth D15 outcomes in practiced, but not unpracticed, subjects with color vision deficiency.\",\"authors\":\"Anne Arah Cho, Jason S Ng\",\"doi\":\"10.1097/OPX.0000000000002159\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Significance: </strong>Imposing a time limit on the Farnsworth D15 test may prevent patients from compromising the test.</p><p><strong>Purpose: </strong>This study aimed to investigate the effect of test time on the Farnsworth D15 color vision test in unpracticed and practiced subjects and determine an optimal test time.</p><p><strong>Methods: </strong>Twenty-one subjects (mean/standard deviation age, 33.1/9.3 years) with a range of congenital color vision deficiency participated in the study. Pseudoisochromatic plate screening, Farnsworth D15, and anomaloscope testing were performed for classification purposes. At each of 2 visits, 10 trials of the Farnsworth D15 were performed with a range in test times from 30 seconds to 10 minutes. Between visits, subjects practiced the test. Major crossovers were used as the outcome measure. A repeated-measures analysis of variance compared the scores across trials. Post hoc Dunnett's testing analyzed the pairwise data.</p><p><strong>Results: </strong>Although no significant difference in the mean number of major crossovers was found across the 10 trials for the first visit ( F (9, 180) = 1.30, p=0.24), a significant difference was found for the second visit ( F (9, 180) = 4.77, p<0.001). The range of mean number of major crossovers for the second visit was 1.71 to 5.1, with the 30-second trial resulting in the largest number of major crossovers and the longest trial resulting in the smallest number of major crossovers. Analysis showed that a 2-minute time limit resulted in a Farnsworth D15 outcome that would be expected based on the anomaloscope for a majority of subjects.</p><p><strong>Conclusions: </strong>In this study, test time was found to affect performance in practiced subjects but not in unpracticed subjects. Based on this study, we recommend enforcing a time limit of 2 minutes to discourage those who try to pass the Farnsworth D15 through practice. Additional measures, such as recording patient behavior, can also be taken.</p>\",\"PeriodicalId\":19649,\"journal\":{\"name\":\"Optometry and Vision Science\",\"volume\":\" \",\"pages\":\"477-484\"},\"PeriodicalIF\":1.6000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Optometry and Vision Science\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/OPX.0000000000002159\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/22 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Optometry and Vision Science","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/OPX.0000000000002159","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

意义:目的:本研究旨在调查测试时间对未练习和练习过的受试者进行 Farnsworth D15 色觉测试的影响,并确定最佳测试时间:方法:21 名患有不同程度先天性色觉缺陷的受试者(平均/标准差年龄,33.1/9.3 岁)参加了研究。为了进行分类,对受试者进行了假异色板筛查、法恩斯沃斯 D15 和异常镜测试。在两次就诊中,每次进行 10 次 Farnsworth D15 测试,测试时间从 30 秒到 10 分钟不等。在两次就诊之间,受试者会进行测试练习。结果测量采用主要交叉。重复测量方差分析比较了各次试验的得分。邓尼特事后检验分析了配对数据:结果:虽然在第一次访问的 10 次试验中,主要交叉的平均次数没有发现明显差异(F(9, 180) = 1.30,p=0.24),但在第二次访问中发现了明显差异(F(9, 180) = 4.77,p结论:本研究发现,测试时间会影响练习者的成绩,但不会影响未练习者的成绩。根据这项研究,我们建议将时间限制为 2 分钟,以阻止那些试图通过练习通过 Farnsworth D15 考试的人。还可以采取其他措施,如记录患者的行为。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Test time affects Farnsworth D15 outcomes in practiced, but not unpracticed, subjects with color vision deficiency.

Significance: Imposing a time limit on the Farnsworth D15 test may prevent patients from compromising the test.

Purpose: This study aimed to investigate the effect of test time on the Farnsworth D15 color vision test in unpracticed and practiced subjects and determine an optimal test time.

Methods: Twenty-one subjects (mean/standard deviation age, 33.1/9.3 years) with a range of congenital color vision deficiency participated in the study. Pseudoisochromatic plate screening, Farnsworth D15, and anomaloscope testing were performed for classification purposes. At each of 2 visits, 10 trials of the Farnsworth D15 were performed with a range in test times from 30 seconds to 10 minutes. Between visits, subjects practiced the test. Major crossovers were used as the outcome measure. A repeated-measures analysis of variance compared the scores across trials. Post hoc Dunnett's testing analyzed the pairwise data.

Results: Although no significant difference in the mean number of major crossovers was found across the 10 trials for the first visit ( F (9, 180) = 1.30, p=0.24), a significant difference was found for the second visit ( F (9, 180) = 4.77, p<0.001). The range of mean number of major crossovers for the second visit was 1.71 to 5.1, with the 30-second trial resulting in the largest number of major crossovers and the longest trial resulting in the smallest number of major crossovers. Analysis showed that a 2-minute time limit resulted in a Farnsworth D15 outcome that would be expected based on the anomaloscope for a majority of subjects.

Conclusions: In this study, test time was found to affect performance in practiced subjects but not in unpracticed subjects. Based on this study, we recommend enforcing a time limit of 2 minutes to discourage those who try to pass the Farnsworth D15 through practice. Additional measures, such as recording patient behavior, can also be taken.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Optometry and Vision Science
Optometry and Vision Science 医学-眼科学
CiteScore
2.80
自引率
7.10%
发文量
210
审稿时长
3-6 weeks
期刊介绍: Optometry and Vision Science is the monthly peer-reviewed scientific publication of the American Academy of Optometry, publishing original research since 1924. Optometry and Vision Science is an internationally recognized source for education and information on current discoveries in optometry, physiological optics, vision science, and related fields. The journal considers original contributions that advance clinical practice, vision science, and public health. Authors should remember that the journal reaches readers worldwide and their submissions should be relevant and of interest to a broad audience. Topical priorities include, but are not limited to: clinical and laboratory research, evidence-based reviews, contact lenses, ocular growth and refractive error development, eye movements, visual function and perception, biology of the eye and ocular disease, epidemiology and public health, biomedical optics and instrumentation, novel and important clinical observations and treatments, and optometric education.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信