Arunkumar H S, Madhwesh N, Anirudh Hegde K, Manjunath Mallashetty Shivamallaiah, Kota Vasudeva Karanth, Younes Amini
{"title":"倒角涡轮对太阳能空气加热器性能的影响 - 数值研究","authors":"Arunkumar H S, Madhwesh N, Anirudh Hegde K, Manjunath Mallashetty Shivamallaiah, Kota Vasudeva Karanth, Younes Amini","doi":"10.37934/cfdl.16.11.1736","DOIUrl":null,"url":null,"abstract":"This paper presents a numerical analysis of the thermal performance improvement in a flat plate solar air heater equipped with chamfered turbulators attached below the absorber plate for evaluating performance for Reynolds numbers ranging from 3,000 to 21,000. According to the research, chamfered turbulators caused the flow to become highly turbulent. This flow behaviour with flow separation around the turbulators positively affects performance. This paper attempts to explain the complex flow behaviour found during the analysis. The turbulator diameter varies in 1 mm increments from 3 to 7 mm at a constant longitudinal pitch of 200 mm. The number of turbulator rows in the transverse direction is kept constant at three. The chamfer is represented by the flow attack angle, which can be 30°, 45°, or 60° facing the direction of flow and opposing the direction of flow. The results showed that a 7mm diameter turbulator with a 30° chamfer angle placed against the flow of air yielded a considerably more significant thermal enhancement factor of 1.15 over the spectrum of flow Reynolds number studied","PeriodicalId":9736,"journal":{"name":"CFD Letters","volume":" 3","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of Chamfered Turbulators on Performance of Solar Air Heater - Numerical Study\",\"authors\":\"Arunkumar H S, Madhwesh N, Anirudh Hegde K, Manjunath Mallashetty Shivamallaiah, Kota Vasudeva Karanth, Younes Amini\",\"doi\":\"10.37934/cfdl.16.11.1736\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper presents a numerical analysis of the thermal performance improvement in a flat plate solar air heater equipped with chamfered turbulators attached below the absorber plate for evaluating performance for Reynolds numbers ranging from 3,000 to 21,000. According to the research, chamfered turbulators caused the flow to become highly turbulent. This flow behaviour with flow separation around the turbulators positively affects performance. This paper attempts to explain the complex flow behaviour found during the analysis. The turbulator diameter varies in 1 mm increments from 3 to 7 mm at a constant longitudinal pitch of 200 mm. The number of turbulator rows in the transverse direction is kept constant at three. The chamfer is represented by the flow attack angle, which can be 30°, 45°, or 60° facing the direction of flow and opposing the direction of flow. The results showed that a 7mm diameter turbulator with a 30° chamfer angle placed against the flow of air yielded a considerably more significant thermal enhancement factor of 1.15 over the spectrum of flow Reynolds number studied\",\"PeriodicalId\":9736,\"journal\":{\"name\":\"CFD Letters\",\"volume\":\" 3\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CFD Letters\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.37934/cfdl.16.11.1736\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Mathematics\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CFD Letters","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.37934/cfdl.16.11.1736","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Mathematics","Score":null,"Total":0}
Effect of Chamfered Turbulators on Performance of Solar Air Heater - Numerical Study
This paper presents a numerical analysis of the thermal performance improvement in a flat plate solar air heater equipped with chamfered turbulators attached below the absorber plate for evaluating performance for Reynolds numbers ranging from 3,000 to 21,000. According to the research, chamfered turbulators caused the flow to become highly turbulent. This flow behaviour with flow separation around the turbulators positively affects performance. This paper attempts to explain the complex flow behaviour found during the analysis. The turbulator diameter varies in 1 mm increments from 3 to 7 mm at a constant longitudinal pitch of 200 mm. The number of turbulator rows in the transverse direction is kept constant at three. The chamfer is represented by the flow attack angle, which can be 30°, 45°, or 60° facing the direction of flow and opposing the direction of flow. The results showed that a 7mm diameter turbulator with a 30° chamfer angle placed against the flow of air yielded a considerably more significant thermal enhancement factor of 1.15 over the spectrum of flow Reynolds number studied