{"title":"基于时间常数数据库评估油浸纸衬套的绝缘状况","authors":"Hossein Taghizade Ansari, Abolfazl Vahedi, Nami Mahmoudi","doi":"10.1049/elp2.12472","DOIUrl":null,"url":null,"abstract":"<p>Assessing the insulation condition of oil-impregnated paper (OIP) bushings is necessary to guarantee the safe operation of power transformers. Moisture is the main threat to the insulation of OIP bushings. Therefore, accurately estimating their moisture value is crucial to keep power systems running smoothly. However, it has been suggested that the ageing status of OIP bushings should be considered while assessing the moisture. Dielectric frequency-domain spectroscopy (FDS) has been extensively employed for assessing insulation condition of OIP insulations due to its benefits. A new approach was proposed to assess the insulation condition of OIP bushings using FDS results. Various OIP samples with various moisture levels and degrees of polymerisation (DP) were selected. The extended Debye model (EDM) parameters related to each sample were calculated using their tan<i>δ</i> − <i>f</i> curve. A time constant database (TCD) was created using the obtained time constants of EDM, which includes the dominant time constant and time constant related to the <i>R</i><sub>0</sub> – <i>C</i><sub>0</sub> branch, and their corresponding insulation condition. Then, a method was introduced based on the created TCD to estimate the insulation condition of OIP bushings. The results showed that the average relative error of moisture and DP estimation is 8.33% and 6.32%, respectively.</p>","PeriodicalId":13352,"journal":{"name":"Iet Electric Power Applications","volume":"18 10","pages":"1233-1243"},"PeriodicalIF":1.5000,"publicationDate":"2024-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12472","citationCount":"0","resultStr":"{\"title\":\"Evaluating the insulation condition of oil-impregnated paper bushings based on the time constant database\",\"authors\":\"Hossein Taghizade Ansari, Abolfazl Vahedi, Nami Mahmoudi\",\"doi\":\"10.1049/elp2.12472\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Assessing the insulation condition of oil-impregnated paper (OIP) bushings is necessary to guarantee the safe operation of power transformers. Moisture is the main threat to the insulation of OIP bushings. Therefore, accurately estimating their moisture value is crucial to keep power systems running smoothly. However, it has been suggested that the ageing status of OIP bushings should be considered while assessing the moisture. Dielectric frequency-domain spectroscopy (FDS) has been extensively employed for assessing insulation condition of OIP insulations due to its benefits. A new approach was proposed to assess the insulation condition of OIP bushings using FDS results. Various OIP samples with various moisture levels and degrees of polymerisation (DP) were selected. The extended Debye model (EDM) parameters related to each sample were calculated using their tan<i>δ</i> − <i>f</i> curve. A time constant database (TCD) was created using the obtained time constants of EDM, which includes the dominant time constant and time constant related to the <i>R</i><sub>0</sub> – <i>C</i><sub>0</sub> branch, and their corresponding insulation condition. Then, a method was introduced based on the created TCD to estimate the insulation condition of OIP bushings. The results showed that the average relative error of moisture and DP estimation is 8.33% and 6.32%, respectively.</p>\",\"PeriodicalId\":13352,\"journal\":{\"name\":\"Iet Electric Power Applications\",\"volume\":\"18 10\",\"pages\":\"1233-1243\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-07-07\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1049/elp2.12472\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Iet Electric Power Applications\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12472\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iet Electric Power Applications","FirstCategoryId":"5","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1049/elp2.12472","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Evaluating the insulation condition of oil-impregnated paper bushings based on the time constant database
Assessing the insulation condition of oil-impregnated paper (OIP) bushings is necessary to guarantee the safe operation of power transformers. Moisture is the main threat to the insulation of OIP bushings. Therefore, accurately estimating their moisture value is crucial to keep power systems running smoothly. However, it has been suggested that the ageing status of OIP bushings should be considered while assessing the moisture. Dielectric frequency-domain spectroscopy (FDS) has been extensively employed for assessing insulation condition of OIP insulations due to its benefits. A new approach was proposed to assess the insulation condition of OIP bushings using FDS results. Various OIP samples with various moisture levels and degrees of polymerisation (DP) were selected. The extended Debye model (EDM) parameters related to each sample were calculated using their tanδ − f curve. A time constant database (TCD) was created using the obtained time constants of EDM, which includes the dominant time constant and time constant related to the R0 – C0 branch, and their corresponding insulation condition. Then, a method was introduced based on the created TCD to estimate the insulation condition of OIP bushings. The results showed that the average relative error of moisture and DP estimation is 8.33% and 6.32%, respectively.
期刊介绍:
IET Electric Power Applications publishes papers of a high technical standard with a suitable balance of practice and theory. The scope covers a wide range of applications and apparatus in the power field. In addition to papers focussing on the design and development of electrical equipment, papers relying on analysis are also sought, provided that the arguments are conveyed succinctly and the conclusions are clear.
The scope of the journal includes the following:
The design and analysis of motors and generators of all sizes
Rotating electrical machines
Linear machines
Actuators
Power transformers
Railway traction machines and drives
Variable speed drives
Machines and drives for electrically powered vehicles
Industrial and non-industrial applications and processes
Current Special Issue. Call for papers:
Progress in Electric Machines, Power Converters and their Control for Wave Energy Generation - https://digital-library.theiet.org/files/IET_EPA_CFP_PEMPCCWEG.pdf