优化新生儿磁共振成像手术镇静的干预包:卡塔尔单中心质量改进项目。

Biomedicine hub Pub Date : 2024-05-22 eCollection Date: 2024-01-01 DOI:10.1159/000538762
Ghalib Daoud, Sanoj Karayil Mohammad Ali, Aravanan Anbu Chakkarapani, Naveed Ur Rehman Durrani
{"title":"优化新生儿磁共振成像手术镇静的干预包:卡塔尔单中心质量改进项目。","authors":"Ghalib Daoud, Sanoj Karayil Mohammad Ali, Aravanan Anbu Chakkarapani, Naveed Ur Rehman Durrani","doi":"10.1159/000538762","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Magnetic resonance imaging (MRI) is a common procedure in tertiary care neonatal intensive care units (NICUs). MRIs aid in detailing structural anatomy and are increasingly utilized for prognostication. Keeping babies calm and motion-free in the MRI suite is challenging, and various approaches have been adopted to obtain the best image quality. We share our experience of intervention bundle for procedural sedation with the novel use of buccal midazolam in our NICU for babies undergoing MRI.</p><p><strong>Methods: </strong>This single-center quality improvement project comprised two epochs. Epoch 1 from April 2018 to December 2020 provided baseline data regarding sedation use and helped identify causes for suboptimal images and the adverse event rate. Following the implementation of an interventional bundle comprising specific midazolam dose recommendations tailored to background risk factors and streamlining the procedural sedation process, similar comparative data were collected in epoch 2 (May 2021 to December 2022) after a washout period.</p><p><strong>Results: </strong>Of 424 patients, 238 and 108 had MRI done under either procedural sedation protocol or feed and wrap technique in epoch 1 and 2, respectively. After excluding babies whose MRIs were performed under sedative infusions, 30 (13%) babies had adverse events in epoch 1, while only 8 (7%) events occurred in epoch 2. There was also a 37% improvement in the documentation of procedural sedation between the two epochs.</p><p><strong>Conclusion: </strong>Procedural sedation with buccal midazolam under neonatologist supervision is safe, efficient, and effective in babies undergoing MRI in this single-center study. More extensive studies may be warranted to assess the suitability of this sedation modality for broader use.</p>","PeriodicalId":101351,"journal":{"name":"Biomedicine hub","volume":"9 1","pages":"73-82"},"PeriodicalIF":0.0000,"publicationDate":"2024-05-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249786/pdf/","citationCount":"0","resultStr":"{\"title\":\"Intervention Bundle for Optimization of Procedural Sedation for Newborns Undergoing Magnetic Resonance Imaging: A Single-Center Quality Improvement Project in Qatar.\",\"authors\":\"Ghalib Daoud, Sanoj Karayil Mohammad Ali, Aravanan Anbu Chakkarapani, Naveed Ur Rehman Durrani\",\"doi\":\"10.1159/000538762\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Magnetic resonance imaging (MRI) is a common procedure in tertiary care neonatal intensive care units (NICUs). MRIs aid in detailing structural anatomy and are increasingly utilized for prognostication. Keeping babies calm and motion-free in the MRI suite is challenging, and various approaches have been adopted to obtain the best image quality. We share our experience of intervention bundle for procedural sedation with the novel use of buccal midazolam in our NICU for babies undergoing MRI.</p><p><strong>Methods: </strong>This single-center quality improvement project comprised two epochs. Epoch 1 from April 2018 to December 2020 provided baseline data regarding sedation use and helped identify causes for suboptimal images and the adverse event rate. Following the implementation of an interventional bundle comprising specific midazolam dose recommendations tailored to background risk factors and streamlining the procedural sedation process, similar comparative data were collected in epoch 2 (May 2021 to December 2022) after a washout period.</p><p><strong>Results: </strong>Of 424 patients, 238 and 108 had MRI done under either procedural sedation protocol or feed and wrap technique in epoch 1 and 2, respectively. After excluding babies whose MRIs were performed under sedative infusions, 30 (13%) babies had adverse events in epoch 1, while only 8 (7%) events occurred in epoch 2. There was also a 37% improvement in the documentation of procedural sedation between the two epochs.</p><p><strong>Conclusion: </strong>Procedural sedation with buccal midazolam under neonatologist supervision is safe, efficient, and effective in babies undergoing MRI in this single-center study. More extensive studies may be warranted to assess the suitability of this sedation modality for broader use.</p>\",\"PeriodicalId\":101351,\"journal\":{\"name\":\"Biomedicine hub\",\"volume\":\"9 1\",\"pages\":\"73-82\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-05-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11249786/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedicine hub\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000538762\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedicine hub","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000538762","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

简介:磁共振成像(MRI)是三级护理新生儿重症监护病房(NICU)的常见程序。核磁共振成像有助于详细了解结构解剖,并越来越多地用于预后判断。让婴儿在核磁共振成像室中保持安静、不乱动是一项挑战,为了获得最佳图像质量,人们采用了各种方法。我们分享了在新生儿重症监护室为接受核磁共振成像检查的婴儿使用口腔咪达唑仑进行程序镇静干预捆绑的经验:该单中心质量改进项目包括两个阶段。第一阶段(2018 年 4 月至 2020 年 12 月)提供了有关镇静剂使用的基线数据,并帮助确定了导致次优图像和不良事件发生率的原因。在实施了包括针对背景风险因素的特定咪达唑仑剂量建议和简化程序镇静流程的介入治疗捆绑项目后,在经过一段时间的冲洗后,在第二阶段(2021 年 5 月至 2022 年 12 月)收集了类似的比较数据:在第 1 和第 2 阶段的 424 名患者中,分别有 238 和 108 名患者在程序镇静方案或喂食和包裹技术下进行了核磁共振成像。在剔除那些在注射镇静剂的情况下进行核磁共振成像的婴儿后,有 30 名婴儿(13%)在第一阶段出现了不良反应,而在第二阶段只有 8 名婴儿(7%)出现了不良反应。两个阶段的程序镇静记录也提高了 37%:结论:在这项单中心研究中,在新生儿科医生的监督下使用口腔咪达唑仑对接受核磁共振成像的婴儿进行程序性镇静是安全、高效和有效的。可能需要进行更广泛的研究,以评估这种镇静方式是否适合更广泛的应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Intervention Bundle for Optimization of Procedural Sedation for Newborns Undergoing Magnetic Resonance Imaging: A Single-Center Quality Improvement Project in Qatar.

Introduction: Magnetic resonance imaging (MRI) is a common procedure in tertiary care neonatal intensive care units (NICUs). MRIs aid in detailing structural anatomy and are increasingly utilized for prognostication. Keeping babies calm and motion-free in the MRI suite is challenging, and various approaches have been adopted to obtain the best image quality. We share our experience of intervention bundle for procedural sedation with the novel use of buccal midazolam in our NICU for babies undergoing MRI.

Methods: This single-center quality improvement project comprised two epochs. Epoch 1 from April 2018 to December 2020 provided baseline data regarding sedation use and helped identify causes for suboptimal images and the adverse event rate. Following the implementation of an interventional bundle comprising specific midazolam dose recommendations tailored to background risk factors and streamlining the procedural sedation process, similar comparative data were collected in epoch 2 (May 2021 to December 2022) after a washout period.

Results: Of 424 patients, 238 and 108 had MRI done under either procedural sedation protocol or feed and wrap technique in epoch 1 and 2, respectively. After excluding babies whose MRIs were performed under sedative infusions, 30 (13%) babies had adverse events in epoch 1, while only 8 (7%) events occurred in epoch 2. There was also a 37% improvement in the documentation of procedural sedation between the two epochs.

Conclusion: Procedural sedation with buccal midazolam under neonatologist supervision is safe, efficient, and effective in babies undergoing MRI in this single-center study. More extensive studies may be warranted to assess the suitability of this sedation modality for broader use.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信