Ebubekir Durmus, Ahmad Kunbaz, Sabire Pelin Kaya, Fehim Esen, Halit Oguz, Veysel Aykut
{"title":"自体纤维蛋白诱导:在玻璃体旁切除术中进行无缝线巩膜切口缝合的新方法","authors":"Ebubekir Durmus, Ahmad Kunbaz, Sabire Pelin Kaya, Fehim Esen, Halit Oguz, Veysel Aykut","doi":"10.1080/02713683.2024.2380441","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study presents a novel sutureless closure approach for sclerotomies following pars plana vitrectomy (PPV) and assesses its efficacy and safety.</p><p><strong>Methods: </strong>A total of 142 eyes were included in the study. PPV procedures were performed using 23-gauge (23 G) or 25-gauge (25 G) systems. Preoperative characteristics, intraoperative findings, and postoperative outcomes were documented.</p><p><strong>Results: </strong>The cohort included 80 males and 62 females (mean age: 60.4 ± 12 years), primarily undergoing surgery for retinal detachment (59%). Among the patients, 87% underwent 25 G PPV (35% three-port, 52% four-port), while 13% underwent 23 G PPV (12% three-port, 1% four-port). Gas tamponade was administered in all cases, with perfluoropropane used in 45.7% of instances, sulfur hexafluoride in 29.5%, and air in 24.6%. Spontaneous closure was observed in 9.4% (47 of 501) of sclerotomies, autologous-fibrin induction approach successfully closed 75.8% (380 of 501) of the sclerotomies (83.7% of leaking sclerotomies) and 14.7% (74 of 501) of sclerotomies needed sutures. Visual acuity improved postoperatively, and first-day hypotony rate was 6.3%. Importantly, no serious complications such as choroidal detachment or endophthalmitis were observed during the postoperative period.</p><p><strong>Conclusion: </strong>The autologous-fibrin induction offers a simple, cost-efficient, and reliable approach for sutureless sclerotomy closure in PPV, with promising outcomes.</p>","PeriodicalId":10782,"journal":{"name":"Current Eye Research","volume":" ","pages":"1308-1312"},"PeriodicalIF":1.7000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Autologous-Fibrin Induction: A Novel Approach for Sutureless Sclerotomy Closure in Pars Plana Vitrectomy.\",\"authors\":\"Ebubekir Durmus, Ahmad Kunbaz, Sabire Pelin Kaya, Fehim Esen, Halit Oguz, Veysel Aykut\",\"doi\":\"10.1080/02713683.2024.2380441\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>This study presents a novel sutureless closure approach for sclerotomies following pars plana vitrectomy (PPV) and assesses its efficacy and safety.</p><p><strong>Methods: </strong>A total of 142 eyes were included in the study. PPV procedures were performed using 23-gauge (23 G) or 25-gauge (25 G) systems. Preoperative characteristics, intraoperative findings, and postoperative outcomes were documented.</p><p><strong>Results: </strong>The cohort included 80 males and 62 females (mean age: 60.4 ± 12 years), primarily undergoing surgery for retinal detachment (59%). Among the patients, 87% underwent 25 G PPV (35% three-port, 52% four-port), while 13% underwent 23 G PPV (12% three-port, 1% four-port). Gas tamponade was administered in all cases, with perfluoropropane used in 45.7% of instances, sulfur hexafluoride in 29.5%, and air in 24.6%. Spontaneous closure was observed in 9.4% (47 of 501) of sclerotomies, autologous-fibrin induction approach successfully closed 75.8% (380 of 501) of the sclerotomies (83.7% of leaking sclerotomies) and 14.7% (74 of 501) of sclerotomies needed sutures. Visual acuity improved postoperatively, and first-day hypotony rate was 6.3%. Importantly, no serious complications such as choroidal detachment or endophthalmitis were observed during the postoperative period.</p><p><strong>Conclusion: </strong>The autologous-fibrin induction offers a simple, cost-efficient, and reliable approach for sutureless sclerotomy closure in PPV, with promising outcomes.</p>\",\"PeriodicalId\":10782,\"journal\":{\"name\":\"Current Eye Research\",\"volume\":\" \",\"pages\":\"1308-1312\"},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Eye Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1080/02713683.2024.2380441\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Eye Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/02713683.2024.2380441","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Autologous-Fibrin Induction: A Novel Approach for Sutureless Sclerotomy Closure in Pars Plana Vitrectomy.
Purpose: This study presents a novel sutureless closure approach for sclerotomies following pars plana vitrectomy (PPV) and assesses its efficacy and safety.
Methods: A total of 142 eyes were included in the study. PPV procedures were performed using 23-gauge (23 G) or 25-gauge (25 G) systems. Preoperative characteristics, intraoperative findings, and postoperative outcomes were documented.
Results: The cohort included 80 males and 62 females (mean age: 60.4 ± 12 years), primarily undergoing surgery for retinal detachment (59%). Among the patients, 87% underwent 25 G PPV (35% three-port, 52% four-port), while 13% underwent 23 G PPV (12% three-port, 1% four-port). Gas tamponade was administered in all cases, with perfluoropropane used in 45.7% of instances, sulfur hexafluoride in 29.5%, and air in 24.6%. Spontaneous closure was observed in 9.4% (47 of 501) of sclerotomies, autologous-fibrin induction approach successfully closed 75.8% (380 of 501) of the sclerotomies (83.7% of leaking sclerotomies) and 14.7% (74 of 501) of sclerotomies needed sutures. Visual acuity improved postoperatively, and first-day hypotony rate was 6.3%. Importantly, no serious complications such as choroidal detachment or endophthalmitis were observed during the postoperative period.
Conclusion: The autologous-fibrin induction offers a simple, cost-efficient, and reliable approach for sutureless sclerotomy closure in PPV, with promising outcomes.
期刊介绍:
The principal aim of Current Eye Research is to provide rapid publication of full papers, short communications and mini-reviews, all high quality. Current Eye Research publishes articles encompassing all the areas of eye research. Subject areas include the following: clinical research, anatomy, physiology, biophysics, biochemistry, pharmacology, developmental biology, microbiology and immunology.