Ali Sani , Youli Tian , Genhan Zha , Xuan Xiao , Saud Shah , Muhammad Idrees Khan , Liuyin Fan , Qiang Zhang , Weiwen Liu , Yuxin Wang , Ping Chen , Chengxi Cao
{"title":"通过改进的微阵列等电聚焦技术分析成人α-地中海贫血症的高稳定样本装载量","authors":"Ali Sani , Youli Tian , Genhan Zha , Xuan Xiao , Saud Shah , Muhammad Idrees Khan , Liuyin Fan , Qiang Zhang , Weiwen Liu , Yuxin Wang , Ping Chen , Chengxi Cao","doi":"10.1016/j.jchromb.2024.124238","DOIUrl":null,"url":null,"abstract":"<div><p>The isoelectric focusing has realized various improvements, including the protocols and creation of mIEF (microcolumn isoelectric focusing) instruments with excellent sensitivity for screening of diabetes and beta thalassemia. However, the problem of manual sample loading and hydration for the mIEF limits the operational capacity for stably detecting and quantitating most abnormal hemoglobin (Hb). Herein, we provided a high stable sample loading protocol for analysis of alpha thalassemia and Hb variants. In contrast to the previous volume of 20 μl, a 100 µl blood sample solution in this protocol was optimized with mixture of 6.4–7.5 and 3–10 pH carrier ampholytes, pI markers and loaded for 30 mins IPG microcolumn hydration. The hydrated microcolumn was then automatically loaded onto the mIEF chip array to which CH<sub>3</sub>COOH and NH<sub>4</sub>OH act as anodic and cathodic solutions. Lastly, the IEF was run for 9 mins. Hb H, Barts, A<sub>1c</sub>, F, A<sub>2</sub> and CS were simultaneously separated and focused with higher resolution and sensitivity in quantifying H and Barts as low as 0.6 and 0.5 % respectively. Accordingly, there was an enhanced stability and linearity with a rapid assay time of 45 secs per sample. Moreover, analysis showed a fitting linear relationship with conventional technology at <em>R</em><sup>2</sup> = 0.9803 for H and <em>R</em><sup>2</sup> = 0.9728 for Barts thereby indicating greater accuracy confirmed by the AUC. Hence, the developed protocol could simply be employed for high stable and throughput batch sample loading of hydration, and accurate separation and quantitation of Hb variants for alpha and beta thalassemia.</p></div>","PeriodicalId":348,"journal":{"name":"Journal of Chromatography B","volume":"1244 ","pages":"Article 124238"},"PeriodicalIF":2.8000,"publicationDate":"2024-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A high stable sample loading for analysis of adult alpha-thalassemia via the improved microarray isoelectric focusing of Hb species\",\"authors\":\"Ali Sani , Youli Tian , Genhan Zha , Xuan Xiao , Saud Shah , Muhammad Idrees Khan , Liuyin Fan , Qiang Zhang , Weiwen Liu , Yuxin Wang , Ping Chen , Chengxi Cao\",\"doi\":\"10.1016/j.jchromb.2024.124238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The isoelectric focusing has realized various improvements, including the protocols and creation of mIEF (microcolumn isoelectric focusing) instruments with excellent sensitivity for screening of diabetes and beta thalassemia. However, the problem of manual sample loading and hydration for the mIEF limits the operational capacity for stably detecting and quantitating most abnormal hemoglobin (Hb). Herein, we provided a high stable sample loading protocol for analysis of alpha thalassemia and Hb variants. In contrast to the previous volume of 20 μl, a 100 µl blood sample solution in this protocol was optimized with mixture of 6.4–7.5 and 3–10 pH carrier ampholytes, pI markers and loaded for 30 mins IPG microcolumn hydration. The hydrated microcolumn was then automatically loaded onto the mIEF chip array to which CH<sub>3</sub>COOH and NH<sub>4</sub>OH act as anodic and cathodic solutions. Lastly, the IEF was run for 9 mins. Hb H, Barts, A<sub>1c</sub>, F, A<sub>2</sub> and CS were simultaneously separated and focused with higher resolution and sensitivity in quantifying H and Barts as low as 0.6 and 0.5 % respectively. Accordingly, there was an enhanced stability and linearity with a rapid assay time of 45 secs per sample. Moreover, analysis showed a fitting linear relationship with conventional technology at <em>R</em><sup>2</sup> = 0.9803 for H and <em>R</em><sup>2</sup> = 0.9728 for Barts thereby indicating greater accuracy confirmed by the AUC. Hence, the developed protocol could simply be employed for high stable and throughput batch sample loading of hydration, and accurate separation and quantitation of Hb variants for alpha and beta thalassemia.</p></div>\",\"PeriodicalId\":348,\"journal\":{\"name\":\"Journal of Chromatography B\",\"volume\":\"1244 \",\"pages\":\"Article 124238\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-07-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Chromatography B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1570023224002472\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Chromatography B","FirstCategoryId":"1","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1570023224002472","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
A high stable sample loading for analysis of adult alpha-thalassemia via the improved microarray isoelectric focusing of Hb species
The isoelectric focusing has realized various improvements, including the protocols and creation of mIEF (microcolumn isoelectric focusing) instruments with excellent sensitivity for screening of diabetes and beta thalassemia. However, the problem of manual sample loading and hydration for the mIEF limits the operational capacity for stably detecting and quantitating most abnormal hemoglobin (Hb). Herein, we provided a high stable sample loading protocol for analysis of alpha thalassemia and Hb variants. In contrast to the previous volume of 20 μl, a 100 µl blood sample solution in this protocol was optimized with mixture of 6.4–7.5 and 3–10 pH carrier ampholytes, pI markers and loaded for 30 mins IPG microcolumn hydration. The hydrated microcolumn was then automatically loaded onto the mIEF chip array to which CH3COOH and NH4OH act as anodic and cathodic solutions. Lastly, the IEF was run for 9 mins. Hb H, Barts, A1c, F, A2 and CS were simultaneously separated and focused with higher resolution and sensitivity in quantifying H and Barts as low as 0.6 and 0.5 % respectively. Accordingly, there was an enhanced stability and linearity with a rapid assay time of 45 secs per sample. Moreover, analysis showed a fitting linear relationship with conventional technology at R2 = 0.9803 for H and R2 = 0.9728 for Barts thereby indicating greater accuracy confirmed by the AUC. Hence, the developed protocol could simply be employed for high stable and throughput batch sample loading of hydration, and accurate separation and quantitation of Hb variants for alpha and beta thalassemia.
期刊介绍:
The Journal of Chromatography B publishes papers on developments in separation science relevant to biology and biomedical research including both fundamental advances and applications. Analytical techniques which may be considered include the various facets of chromatography, electrophoresis and related methods, affinity and immunoaffinity-based methodologies, hyphenated and other multi-dimensional techniques, and microanalytical approaches. The journal also considers articles reporting developments in sample preparation, detection techniques including mass spectrometry, and data handling and analysis.
Developments related to preparative separations for the isolation and purification of components of biological systems may be published, including chromatographic and electrophoretic methods, affinity separations, field flow fractionation and other preparative approaches.
Applications to the analysis of biological systems and samples will be considered when the analytical science contains a significant element of novelty, e.g. a new approach to the separation of a compound, novel combination of analytical techniques, or significantly improved analytical performance.