{"title":"根据 ISO 81060-2:2018/AMD 1:2020 协议,在普通人群中验证 DBP-8278B 腕式全自动血压计。","authors":"Qi Zhou","doi":"10.1097/MBP.0000000000000717","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the accuracy of the DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor in the general population according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018/AMD 1 : 2020). The test monitor was used to measure SBP and DBP and pulse rate in the wrists using the oscillometric method. According to this protocol using the same-arm sequential blood pressure measurement method, subjects were recruited to fulfill the age, sex, blood pressure, and cuff distribution criteria of the Universal Standard. A single cuff for wrist sizes of 13.5-21.5 cm was used. A total of 85 subjects were included in this study. According to Criterion 1, the mean difference in SBP between the test device and the reference device was 0.89 mmHg, with a SD of 7.76 mmHg. The mean difference of DBP was -1.44 mmHg, with a SD of 6.23 mmHg. The mean difference between SBP and DBP was less than 5.0 mmHg, and the SD was less than 8.0 mmHg, which met the requirements. According to Criterion 2, the SD of the mean differences of SBP between the test device and the reference device per subject was 5.65 mmHg, which was less than 6.88 mmHg and met the requirements. The SD of the mean differences of DBP between the test device and the reference device per subject was 5.61 mmHg, which was less than 6.78 mmHg and met the requirements. The DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor met the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018/AMD 1 : 2020). It can be recommended for home and clinical use.</p>","PeriodicalId":8950,"journal":{"name":"Blood Pressure Monitoring","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validation of the DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor in the general population according to the ISO 81060-2:2018/AMD 1:2020 protocol.\",\"authors\":\"Qi Zhou\",\"doi\":\"10.1097/MBP.0000000000000717\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this study was to evaluate the accuracy of the DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor in the general population according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018/AMD 1 : 2020). The test monitor was used to measure SBP and DBP and pulse rate in the wrists using the oscillometric method. According to this protocol using the same-arm sequential blood pressure measurement method, subjects were recruited to fulfill the age, sex, blood pressure, and cuff distribution criteria of the Universal Standard. A single cuff for wrist sizes of 13.5-21.5 cm was used. A total of 85 subjects were included in this study. According to Criterion 1, the mean difference in SBP between the test device and the reference device was 0.89 mmHg, with a SD of 7.76 mmHg. The mean difference of DBP was -1.44 mmHg, with a SD of 6.23 mmHg. The mean difference between SBP and DBP was less than 5.0 mmHg, and the SD was less than 8.0 mmHg, which met the requirements. According to Criterion 2, the SD of the mean differences of SBP between the test device and the reference device per subject was 5.65 mmHg, which was less than 6.88 mmHg and met the requirements. The SD of the mean differences of DBP between the test device and the reference device per subject was 5.61 mmHg, which was less than 6.78 mmHg and met the requirements. The DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor met the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018/AMD 1 : 2020). It can be recommended for home and clinical use.</p>\",\"PeriodicalId\":8950,\"journal\":{\"name\":\"Blood Pressure Monitoring\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-07-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Blood Pressure Monitoring\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/MBP.0000000000000717\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"PERIPHERAL VASCULAR DISEASE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Blood Pressure Monitoring","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/MBP.0000000000000717","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"PERIPHERAL VASCULAR DISEASE","Score":null,"Total":0}
Validation of the DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor in the general population according to the ISO 81060-2:2018/AMD 1:2020 protocol.
The aim of this study was to evaluate the accuracy of the DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor in the general population according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018/AMD 1 : 2020). The test monitor was used to measure SBP and DBP and pulse rate in the wrists using the oscillometric method. According to this protocol using the same-arm sequential blood pressure measurement method, subjects were recruited to fulfill the age, sex, blood pressure, and cuff distribution criteria of the Universal Standard. A single cuff for wrist sizes of 13.5-21.5 cm was used. A total of 85 subjects were included in this study. According to Criterion 1, the mean difference in SBP between the test device and the reference device was 0.89 mmHg, with a SD of 7.76 mmHg. The mean difference of DBP was -1.44 mmHg, with a SD of 6.23 mmHg. The mean difference between SBP and DBP was less than 5.0 mmHg, and the SD was less than 8.0 mmHg, which met the requirements. According to Criterion 2, the SD of the mean differences of SBP between the test device and the reference device per subject was 5.65 mmHg, which was less than 6.88 mmHg and met the requirements. The SD of the mean differences of DBP between the test device and the reference device per subject was 5.61 mmHg, which was less than 6.78 mmHg and met the requirements. The DBP-8278B Wrist-type Fully Automatic Blood Pressure Monitor met the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2 : 2018/AMD 1 : 2020). It can be recommended for home and clinical use.
期刊介绍:
Blood Pressure Monitoring is devoted to original research in blood pressure measurement and blood pressure variability. It includes device technology, analytical methodology of blood pressure over time and its variability, clinical trials - including, but not limited to, pharmacology - involving blood pressure monitoring, blood pressure reactivity, patient evaluation, and outcomes and effectiveness research.
This innovative journal contains papers dealing with all aspects of manual, automated, and ambulatory monitoring. Basic and clinical science papers are considered although the emphasis is on clinical medicine.
Submitted articles undergo a preliminary review by the editor. Some articles may be returned to authors without further consideration. Those being considered for publication will undergo further assessment and peer-review by the editors and those invited to do so from a reviewer pool.