Julia Hernández-Lucena, Federico Alonso-Aliste, Jonatan Amián-Cordero, José-María Sánchez-González
{"title":"蔡司 PRESBYOND 激光混合视力 LASIK 使用默认自定义屈光软件主目标屈光度以减少散光的角膜复合远视散光与老花的疗效。","authors":"Julia Hernández-Lucena, Federico Alonso-Aliste, Jonatan Amián-Cordero, José-María Sánchez-González","doi":"10.3928/1081597X-20240506-02","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period.</p><p><strong>Methods: </strong>A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes.</p><p><strong>Results: </strong>Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery.</p><p><strong>Conclusions: </strong>This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. <b>[ <i>J Refract Surg.</i> 2024;40(7):e480-e489.]</b>.</p>","PeriodicalId":16951,"journal":{"name":"Journal of refractive surgery","volume":"40 7","pages":"e480-e489"},"PeriodicalIF":2.9000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Outcomes of Corneal Compound Hyperopic Astigmatism With Presbyopia by Zeiss PRESBYOND Laser Blended Vision LASIK Using Default Custom Refractive Software Master Target Refractions for Reduced Anisometropia.\",\"authors\":\"Julia Hernández-Lucena, Federico Alonso-Aliste, Jonatan Amián-Cordero, José-María Sánchez-González\",\"doi\":\"10.3928/1081597X-20240506-02\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period.</p><p><strong>Methods: </strong>A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes.</p><p><strong>Results: </strong>Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery.</p><p><strong>Conclusions: </strong>This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. <b>[ <i>J Refract Surg.</i> 2024;40(7):e480-e489.]</b>.</p>\",\"PeriodicalId\":16951,\"journal\":{\"name\":\"Journal of refractive surgery\",\"volume\":\"40 7\",\"pages\":\"e480-e489\"},\"PeriodicalIF\":2.9000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of refractive surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.3928/1081597X-20240506-02\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of refractive surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3928/1081597X-20240506-02","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Outcomes of Corneal Compound Hyperopic Astigmatism With Presbyopia by Zeiss PRESBYOND Laser Blended Vision LASIK Using Default Custom Refractive Software Master Target Refractions for Reduced Anisometropia.
Purpose: To evaluate the effectiveness, safety, and stability of a modified PRESBYOND Laser Blended Vision protocol (Carl Zeiss Meditec AG) for correcting hyperopic astigmatism and presbyopia, using Custom Refractive Software Master (CRSM) targeting over a 6-month period.
Methods: A total of 636 eyes of 318 patients with a mean age of 51.05 ± 4.71 years (range: 40 to 60 years) met the inclusion and exclusion criteria. All patients completed a 6-month follow-up. CRSM software was used to generate ablation profiles for the MEL90 excimer laser (Carl Zeiss Meditec AG). The target refraction was emmetropic for the dominant eyes and between -0.75 and -1.12 diopters (D) for the near eyes.
Results: Visual and refractive results were studied separately by the dominant and non-dominant eyes. The mean attempt to correct for spherical equivalent refraction was +2.17 ± 1.16 D (range: -1.00 to +5.37 D). The mean attempted cylinder was -0.60 ± 0.75 D (range: -4.00 to 0.00 D). All eyes monocularly achieved uncorrected distance visual acuity (UDVA) of 20/25 or better after refractive treatment and 88% achieved 20/20. Binocularly all eyes achieved UDVA of 20/25 or better and 96.54% achieved 20/20. Ninety-eight percent of the patients maintained their corrected distance visual acuity before surgery and UDVA 6 months after surgery.
Conclusions: This hyperopic micro-anisometropia protocol with PRESBYOND Laser Blended Vision was an effective, safe, and well-tolerated refractive treatment. It was an effective procedure with excellent results for UDVA and uncorrected near visual acuity and demonstrates that binocular summation exists. [ J Refract Surg. 2024;40(7):e480-e489.].
期刊介绍:
The Journal of Refractive Surgery, the official journal of the International Society of Refractive Surgery, a partner of the American Academy of Ophthalmology, has been a monthly peer-reviewed forum for original research, review, and evaluation of refractive and lens-based surgical procedures for more than 30 years. Practical, clinically valuable articles provide readers with the most up-to-date information regarding advances in the field of refractive surgery. Begin to explore the Journal and all of its great benefits such as:
• Columns including “Translational Science,” “Surgical Techniques,” and “Biomechanics”
• Supplemental videos and materials available for many articles
• Access to current articles, as well as several years of archived content
• Articles posted online just 2 months after acceptance.