临床前 SPECT 和 PET:EANM 和 ESMI 联合程序指南,用于实施有效的质量控制计划。

IF 8.6 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Christian Vanhove, Michel Koole, Pedro Fragoso Costa, Margret Schottelius, Julia Mannheim, Claudia Kuntner, Geoff Warnock, Wendy McDougald, Adriana Tavares, Monique Bernsen
{"title":"临床前 SPECT 和 PET:EANM 和 ESMI 联合程序指南,用于实施有效的质量控制计划。","authors":"Christian Vanhove, Michel Koole, Pedro Fragoso Costa, Margret Schottelius, Julia Mannheim, Claudia Kuntner, Geoff Warnock, Wendy McDougald, Adriana Tavares, Monique Bernsen","doi":"10.1007/s00259-024-06824-5","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this guideline is to provide recommendations for the implementation of an effective and efficient quality control (QC) programme for SPECT and PET systems in a preclinical imaging lab. These recommendations aim to strengthen the translational power of preclinical imaging results obtained using preclinical SPECT and PET. As for clinical imaging, reliability, reproducibility, and repeatability are essential when groups of animals are used in a longitudinal imaging experiment. The larger the variability of the imaging endpoint, the more animals are needed to be able to observe statistically significant differences between groups. Therefore, preclinical imaging requires quality control procedures to maintain reliability, reproducibility, and repeatability of imaging procedures, and to ensure the accuracy and precision of SPECT and PET quantification. While the Physics Committee of the European Association of Nuclear Medicine (EANM) has already published excellent procedure guidelines for Routine Quality Control Recommendations for Nuclear Medicine Instrumentation that also includes procedures for small animal PET systems, and important steps have already been made concerning preclinical quality control aspects, this new guideline provides a review and update of these previous guidelines such that guidelines are also adapted to new technological developments.</p>","PeriodicalId":11909,"journal":{"name":"European Journal of Nuclear Medicine and Molecular Imaging","volume":null,"pages":null},"PeriodicalIF":8.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11527901/pdf/","citationCount":"0","resultStr":"{\"title\":\"Preclinical SPECT and PET: Joint EANM and ESMI procedure guideline for implementing an efficient quality control programme.\",\"authors\":\"Christian Vanhove, Michel Koole, Pedro Fragoso Costa, Margret Schottelius, Julia Mannheim, Claudia Kuntner, Geoff Warnock, Wendy McDougald, Adriana Tavares, Monique Bernsen\",\"doi\":\"10.1007/s00259-024-06824-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The aim of this guideline is to provide recommendations for the implementation of an effective and efficient quality control (QC) programme for SPECT and PET systems in a preclinical imaging lab. These recommendations aim to strengthen the translational power of preclinical imaging results obtained using preclinical SPECT and PET. As for clinical imaging, reliability, reproducibility, and repeatability are essential when groups of animals are used in a longitudinal imaging experiment. The larger the variability of the imaging endpoint, the more animals are needed to be able to observe statistically significant differences between groups. Therefore, preclinical imaging requires quality control procedures to maintain reliability, reproducibility, and repeatability of imaging procedures, and to ensure the accuracy and precision of SPECT and PET quantification. While the Physics Committee of the European Association of Nuclear Medicine (EANM) has already published excellent procedure guidelines for Routine Quality Control Recommendations for Nuclear Medicine Instrumentation that also includes procedures for small animal PET systems, and important steps have already been made concerning preclinical quality control aspects, this new guideline provides a review and update of these previous guidelines such that guidelines are also adapted to new technological developments.</p>\",\"PeriodicalId\":11909,\"journal\":{\"name\":\"European Journal of Nuclear Medicine and Molecular Imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11527901/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European Journal of Nuclear Medicine and Molecular Imaging\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00259-024-06824-5\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/15 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European Journal of Nuclear Medicine and Molecular Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00259-024-06824-5","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/15 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

本指南旨在为临床前成像实验室的 SPECT 和 PET 系统实施有效且高效的质量控制 (QC) 计划提供建议。这些建议旨在加强利用临床前 SPECT 和 PET 获得的临床前成像结果的转化能力。至于临床成像,在纵向成像实验中使用动物组时,可靠性、再现性和可重复性至关重要。成像终点的变异性越大,就需要更多的动物才能观察到组间具有统计学意义的差异。因此,临床前成像需要质量控制程序,以保持成像程序的可靠性、再现性和可重复性,并确保 SPECT 和 PET 定量的准确性和精确性。虽然欧洲核医学协会(EANM)物理委员会已经发布了《核医学仪器常规质量控制建议》的优秀程序指南,其中也包括小动物 PET 系统的程序,并且已经在临床前质量控制方面采取了重要措施,但这份新指南对以前的指南进行了回顾和更新,使指南也能适应新的技术发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Preclinical SPECT and PET: Joint EANM and ESMI procedure guideline for implementing an efficient quality control programme.

Preclinical SPECT and PET: Joint EANM and ESMI procedure guideline for implementing an efficient quality control programme.

The aim of this guideline is to provide recommendations for the implementation of an effective and efficient quality control (QC) programme for SPECT and PET systems in a preclinical imaging lab. These recommendations aim to strengthen the translational power of preclinical imaging results obtained using preclinical SPECT and PET. As for clinical imaging, reliability, reproducibility, and repeatability are essential when groups of animals are used in a longitudinal imaging experiment. The larger the variability of the imaging endpoint, the more animals are needed to be able to observe statistically significant differences between groups. Therefore, preclinical imaging requires quality control procedures to maintain reliability, reproducibility, and repeatability of imaging procedures, and to ensure the accuracy and precision of SPECT and PET quantification. While the Physics Committee of the European Association of Nuclear Medicine (EANM) has already published excellent procedure guidelines for Routine Quality Control Recommendations for Nuclear Medicine Instrumentation that also includes procedures for small animal PET systems, and important steps have already been made concerning preclinical quality control aspects, this new guideline provides a review and update of these previous guidelines such that guidelines are also adapted to new technological developments.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
15.60
自引率
9.90%
发文量
392
审稿时长
3 months
期刊介绍: The European Journal of Nuclear Medicine and Molecular Imaging serves as a platform for the exchange of clinical and scientific information within nuclear medicine and related professions. It welcomes international submissions from professionals involved in the functional, metabolic, and molecular investigation of diseases. The journal's coverage spans physics, dosimetry, radiation biology, radiochemistry, and pharmacy, providing high-quality peer review by experts in the field. Known for highly cited and downloaded articles, it ensures global visibility for research work and is part of the EJNMMI journal family.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信