{"title":"小切口角膜透镜摘除术矫正高度近视三年后角膜中央基质厚度降低的结果。","authors":"Xian Liu ,&nbsp;Qiang Liu ,&nbsp;Lan-hui Yu ,&nbsp;Rui Xiong ,&nbsp;Sheng-tao Liu ,&nbsp;Zhi-peng You","doi":"10.1016/j.pdpdt.2024.104278","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>To investigate the long-term corneal stromal remodeling and central stromal thickness (CST) reduction accuracy after small-incision lenticule extraction (SMILE) for high myopia correction.</p></div><div><h3>Methods</h3><p>This prospective study included 30 patients (50 eyes) who had undergone SMILE. Measurements of CST reduction using optical coherence tomography were performed at 1 month, 6 months, 1 year, and 3 years after surgery. Correlations were performed between planned and achieved CST reductions.</p></div><div><h3>Results</h3><p>The study enrolled 50 eyes of 30 patients. The mean spherical equivalent was -9.25±1.52 D(diopters). The postoperative CST increased in the first month after surgery and remained stable for a year. Thereafter, it remained stable during follow-up from 1 to 3 years postoperatively. The predicted CST reduction was 146.4 ± 10.3 μm. The achieved CST reductions at 1 month, 6 months, 1 year, and 3 years after surgery were 135.3 ± 12.1 μm, 130.8 ± 10.6 μm, 125.9 ± 9.4 μm, and 122.2 ± 10.6 μm, respectively. An overestimation of CST reduction was observed three years after surgery. Correlation analysis revealed a strong correlation between planned and achieved CST reductions; however, no correlation was found between CST reductions predicted error and the planned CST reductions.</p></div><div><h3>Conclusion</h3><p>During long-term follow-up, our findings revealed a significant stromal remodeling following SMILE in patients with high myopia. Therefore, clinicians should consider it when screening patients with high myopia for SMILE.</p></div>","PeriodicalId":20141,"journal":{"name":"Photodiagnosis and Photodynamic Therapy","volume":"48 ","pages":"Article 104278"},"PeriodicalIF":3.1000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1572100024003156/pdfft?md5=344829c632505c6a2b299c79568cd7c4&pid=1-s2.0-S1572100024003156-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Three-year results of central corneal stromal thickness reduction in small-incision lenticule extraction for high myopia correction\",\"authors\":\"Xian Liu ,&nbsp;Qiang Liu ,&nbsp;Lan-hui Yu ,&nbsp;Rui Xiong ,&nbsp;Sheng-tao Liu ,&nbsp;Zhi-peng You\",\"doi\":\"10.1016/j.pdpdt.2024.104278\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Background</h3><p>To investigate the long-term corneal stromal remodeling and central stromal thickness (CST) reduction accuracy after small-incision lenticule extraction (SMILE) for high myopia correction.</p></div><div><h3>Methods</h3><p>This prospective study included 30 patients (50 eyes) who had undergone SMILE. Measurements of CST reduction using optical coherence tomography were performed at 1 month, 6 months, 1 year, and 3 years after surgery. Correlations were performed between planned and achieved CST reductions.</p></div><div><h3>Results</h3><p>The study enrolled 50 eyes of 30 patients. The mean spherical equivalent was -9.25±1.52 D(diopters). The postoperative CST increased in the first month after surgery and remained stable for a year. Thereafter, it remained stable during follow-up from 1 to 3 years postoperatively. The predicted CST reduction was 146.4 ± 10.3 μm. The achieved CST reductions at 1 month, 6 months, 1 year, and 3 years after surgery were 135.3 ± 12.1 μm, 130.8 ± 10.6 μm, 125.9 ± 9.4 μm, and 122.2 ± 10.6 μm, respectively. An overestimation of CST reduction was observed three years after surgery. Correlation analysis revealed a strong correlation between planned and achieved CST reductions; however, no correlation was found between CST reductions predicted error and the planned CST reductions.</p></div><div><h3>Conclusion</h3><p>During long-term follow-up, our findings revealed a significant stromal remodeling following SMILE in patients with high myopia. Therefore, clinicians should consider it when screening patients with high myopia for SMILE.</p></div>\",\"PeriodicalId\":20141,\"journal\":{\"name\":\"Photodiagnosis and Photodynamic Therapy\",\"volume\":\"48 \",\"pages\":\"Article 104278\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1572100024003156/pdfft?md5=344829c632505c6a2b299c79568cd7c4&pid=1-s2.0-S1572100024003156-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Photodiagnosis and Photodynamic Therapy\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1572100024003156\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"ONCOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Photodiagnosis and Photodynamic Therapy","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1572100024003156","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景:研究小切口人工晶体植入术(SMILE)矫治高度近视后,角膜基质重塑和中央基质厚度(CST)降低的长期准确性:目的:研究小切口人工晶体植入术(SMILE)矫正高度近视后,角膜基质重塑和中央基质厚度(CST)降低的长期准确性:这项前瞻性研究包括30名接受SMILE手术的患者(50只眼)。在术后 1 个月、6 个月、1 年和 3 年使用光学相干断层扫描测量 CST 降低情况。研究结果显示,计划的 CST 降低与实际的 CST 降低之间存在相关性:研究共纳入了 30 名患者的 50 只眼睛。平均球面等效度数为-9.25±1.52 D(屈光度)。术后 CST 在术后第一个月有所增加,并在一年内保持稳定。此后,在术后 1 至 3 年的随访期间,CST 保持稳定。预测的 CST 降低值为 146.4±10.3 μm。术后1个月、6个月、1年和3年的CST缩小量分别为135.3±12.1 μm、130.8±10.6 μm、125.9±9.4 μm和122.2±10.6 μm。术后三年观察到高估了 CST 的缩小。相关性分析表明,计划的 CST 缩窄与实现的 CST 缩窄之间存在很强的相关性;但在 CST 缩窄预测误差与计划的 CST 缩窄之间没有发现相关性:结论:在长期随访中,我们的研究结果表明,SMILE术后,高度近视患者的眼球基质发生了明显的重塑。因此,临床医生在筛选高度近视患者进行SMILE手术时应考虑到这一点。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-year results of central corneal stromal thickness reduction in small-incision lenticule extraction for high myopia correction

Background

To investigate the long-term corneal stromal remodeling and central stromal thickness (CST) reduction accuracy after small-incision lenticule extraction (SMILE) for high myopia correction.

Methods

This prospective study included 30 patients (50 eyes) who had undergone SMILE. Measurements of CST reduction using optical coherence tomography were performed at 1 month, 6 months, 1 year, and 3 years after surgery. Correlations were performed between planned and achieved CST reductions.

Results

The study enrolled 50 eyes of 30 patients. The mean spherical equivalent was -9.25±1.52 D(diopters). The postoperative CST increased in the first month after surgery and remained stable for a year. Thereafter, it remained stable during follow-up from 1 to 3 years postoperatively. The predicted CST reduction was 146.4 ± 10.3 μm. The achieved CST reductions at 1 month, 6 months, 1 year, and 3 years after surgery were 135.3 ± 12.1 μm, 130.8 ± 10.6 μm, 125.9 ± 9.4 μm, and 122.2 ± 10.6 μm, respectively. An overestimation of CST reduction was observed three years after surgery. Correlation analysis revealed a strong correlation between planned and achieved CST reductions; however, no correlation was found between CST reductions predicted error and the planned CST reductions.

Conclusion

During long-term follow-up, our findings revealed a significant stromal remodeling following SMILE in patients with high myopia. Therefore, clinicians should consider it when screening patients with high myopia for SMILE.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.80
自引率
24.20%
发文量
509
审稿时长
50 days
期刊介绍: Photodiagnosis and Photodynamic Therapy is an international journal for the dissemination of scientific knowledge and clinical developments of Photodiagnosis and Photodynamic Therapy in all medical specialties. The journal publishes original articles, review articles, case presentations, "how-to-do-it" articles, Letters to the Editor, short communications and relevant images with short descriptions. All submitted material is subject to a strict peer-review process.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信