{"title":"基于速度和位移的非稳态条件下单传感器旋转叶片监测方法。","authors":"","doi":"10.1016/j.isatra.2024.06.017","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>A novel single-sensor method for monitoring rotating blade vibration is proposed and utilized to identify vibration parameters under the non-stationary condition. By analyzing the pulse-signal waveform, the blade tip displacement and vibration velocity are extracted. Then, the </span>motion equation under the non-stationary condition is further developed to provide a theoretical basis. Finally, the optimization technology is applied to extract vibration parameters. Compared with multiple-sensor methods, the proposed method has lower installation difficulty, less equipment cost, fewer sensors, and no strict sensor layout requirement. Numerical simulations and experiments are conducted to validate the effectiveness and robustness of the proposed method. The </span>relative error in the natural frequency does not exceed 0.1 %. Additionally, errors in other parameters are less than 8 % in the experiment.</p></div>","PeriodicalId":14660,"journal":{"name":"ISA transactions","volume":null,"pages":null},"PeriodicalIF":6.3000,"publicationDate":"2024-06-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Single-sensor rotating blade monitoring method under non-stationary conditions based on velocity and displacement\",\"authors\":\"\",\"doi\":\"10.1016/j.isatra.2024.06.017\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p><span><span>A novel single-sensor method for monitoring rotating blade vibration is proposed and utilized to identify vibration parameters under the non-stationary condition. By analyzing the pulse-signal waveform, the blade tip displacement and vibration velocity are extracted. Then, the </span>motion equation under the non-stationary condition is further developed to provide a theoretical basis. Finally, the optimization technology is applied to extract vibration parameters. Compared with multiple-sensor methods, the proposed method has lower installation difficulty, less equipment cost, fewer sensors, and no strict sensor layout requirement. Numerical simulations and experiments are conducted to validate the effectiveness and robustness of the proposed method. The </span>relative error in the natural frequency does not exceed 0.1 %. Additionally, errors in other parameters are less than 8 % in the experiment.</p></div>\",\"PeriodicalId\":14660,\"journal\":{\"name\":\"ISA transactions\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.3000,\"publicationDate\":\"2024-06-22\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISA transactions\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0019057824003045\",\"RegionNum\":2,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"AUTOMATION & CONTROL SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISA transactions","FirstCategoryId":"94","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0019057824003045","RegionNum":2,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AUTOMATION & CONTROL SYSTEMS","Score":null,"Total":0}
Single-sensor rotating blade monitoring method under non-stationary conditions based on velocity and displacement
A novel single-sensor method for monitoring rotating blade vibration is proposed and utilized to identify vibration parameters under the non-stationary condition. By analyzing the pulse-signal waveform, the blade tip displacement and vibration velocity are extracted. Then, the motion equation under the non-stationary condition is further developed to provide a theoretical basis. Finally, the optimization technology is applied to extract vibration parameters. Compared with multiple-sensor methods, the proposed method has lower installation difficulty, less equipment cost, fewer sensors, and no strict sensor layout requirement. Numerical simulations and experiments are conducted to validate the effectiveness and robustness of the proposed method. The relative error in the natural frequency does not exceed 0.1 %. Additionally, errors in other parameters are less than 8 % in the experiment.
期刊介绍:
ISA Transactions serves as a platform for showcasing advancements in measurement and automation, catering to both industrial practitioners and applied researchers. It covers a wide array of topics within measurement, including sensors, signal processing, data analysis, and fault detection, supported by techniques such as artificial intelligence and communication systems. Automation topics encompass control strategies, modelling, system reliability, and maintenance, alongside optimization and human-machine interaction. The journal targets research and development professionals in control systems, process instrumentation, and automation from academia and industry.