Haonan Bai , Guoxin Zhao , Dezhi Chen , Xiu Zhou , Xiaofeng Zheng
{"title":"变流器铁芯和钳位接地电流监测装置的设计与研究","authors":"Haonan Bai , Guoxin Zhao , Dezhi Chen , Xiu Zhou , Xiaofeng Zheng","doi":"10.1016/j.vlsi.2024.102238","DOIUrl":null,"url":null,"abstract":"<div><p>The effective monitoring of the grounding current of the core and clamp of the converter transformer can prevent partial overheating, gassing of oil, and other abnormal conditions caused by the grounding fault of the core and clamp, ensuring the safety and stability of the power system. At present, the main detection and diagnosis method is to use the clamp current meter to detect the effective value of the grounding current. However, due to the larger capacity, higher voltage level, more complex structure and electromagnetic field distribution of the converter transformer, there is no clear standard and detection diagnosis method. Firstly, this paper analyzes the causes of grounding current and related calculations. And the design of the monitoring system for the grounding current of the converter transformer core and clamp design of the hardware system for the grounding current of the converter transformer is studied and the design process of the main circuit is given. Secondly, aiming at the problem of amplitude measurement deviation and non-integer frequency of harmonic generated by the grounding current of the core and clamp, a harmonic current detection and analysis scheme based on four Blackman-harris algorithms and the specific design process are proposed. Third, a diagnostic method based on probabilistic neural network is proposed, and a software platform is built to display and diagnose the grounding current state according to it. Finally, a prototype was manufactured and experimental study was carried out to verify the correctness of the proposed scheme.</p></div>","PeriodicalId":54973,"journal":{"name":"Integration-The Vlsi Journal","volume":null,"pages":null},"PeriodicalIF":2.2000,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Design and research of grounding current monitoring device for converter transformer core and clamp\",\"authors\":\"Haonan Bai , Guoxin Zhao , Dezhi Chen , Xiu Zhou , Xiaofeng Zheng\",\"doi\":\"10.1016/j.vlsi.2024.102238\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The effective monitoring of the grounding current of the core and clamp of the converter transformer can prevent partial overheating, gassing of oil, and other abnormal conditions caused by the grounding fault of the core and clamp, ensuring the safety and stability of the power system. At present, the main detection and diagnosis method is to use the clamp current meter to detect the effective value of the grounding current. However, due to the larger capacity, higher voltage level, more complex structure and electromagnetic field distribution of the converter transformer, there is no clear standard and detection diagnosis method. Firstly, this paper analyzes the causes of grounding current and related calculations. And the design of the monitoring system for the grounding current of the converter transformer core and clamp design of the hardware system for the grounding current of the converter transformer is studied and the design process of the main circuit is given. Secondly, aiming at the problem of amplitude measurement deviation and non-integer frequency of harmonic generated by the grounding current of the core and clamp, a harmonic current detection and analysis scheme based on four Blackman-harris algorithms and the specific design process are proposed. Third, a diagnostic method based on probabilistic neural network is proposed, and a software platform is built to display and diagnose the grounding current state according to it. Finally, a prototype was manufactured and experimental study was carried out to verify the correctness of the proposed scheme.</p></div>\",\"PeriodicalId\":54973,\"journal\":{\"name\":\"Integration-The Vlsi Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Integration-The Vlsi Journal\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0167926024001020\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Integration-The Vlsi Journal","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0167926024001020","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"COMPUTER SCIENCE, HARDWARE & ARCHITECTURE","Score":null,"Total":0}
Design and research of grounding current monitoring device for converter transformer core and clamp
The effective monitoring of the grounding current of the core and clamp of the converter transformer can prevent partial overheating, gassing of oil, and other abnormal conditions caused by the grounding fault of the core and clamp, ensuring the safety and stability of the power system. At present, the main detection and diagnosis method is to use the clamp current meter to detect the effective value of the grounding current. However, due to the larger capacity, higher voltage level, more complex structure and electromagnetic field distribution of the converter transformer, there is no clear standard and detection diagnosis method. Firstly, this paper analyzes the causes of grounding current and related calculations. And the design of the monitoring system for the grounding current of the converter transformer core and clamp design of the hardware system for the grounding current of the converter transformer is studied and the design process of the main circuit is given. Secondly, aiming at the problem of amplitude measurement deviation and non-integer frequency of harmonic generated by the grounding current of the core and clamp, a harmonic current detection and analysis scheme based on four Blackman-harris algorithms and the specific design process are proposed. Third, a diagnostic method based on probabilistic neural network is proposed, and a software platform is built to display and diagnose the grounding current state according to it. Finally, a prototype was manufactured and experimental study was carried out to verify the correctness of the proposed scheme.
期刊介绍:
Integration''s aim is to cover every aspect of the VLSI area, with an emphasis on cross-fertilization between various fields of science, and the design, verification, test and applications of integrated circuits and systems, as well as closely related topics in process and device technologies. Individual issues will feature peer-reviewed tutorials and articles as well as reviews of recent publications. The intended coverage of the journal can be assessed by examining the following (non-exclusive) list of topics:
Specification methods and languages; Analog/Digital Integrated Circuits and Systems; VLSI architectures; Algorithms, methods and tools for modeling, simulation, synthesis and verification of integrated circuits and systems of any complexity; Embedded systems; High-level synthesis for VLSI systems; Logic synthesis and finite automata; Testing, design-for-test and test generation algorithms; Physical design; Formal verification; Algorithms implemented in VLSI systems; Systems engineering; Heterogeneous systems.