用于图像引导闭环超声神经调制的可穿戴双模探头

Junjun Huan, Vida Pashaei, Steve J A Majerus, Swarup Bhunia, Soumyajit Mandal
{"title":"用于图像引导闭环超声神经调制的可穿戴双模探头","authors":"Junjun Huan, Vida Pashaei, Steve J A Majerus, Swarup Bhunia, Soumyajit Mandal","doi":"10.1109/TBCAS.2024.3425858","DOIUrl":null,"url":null,"abstract":"<p><p>Low-intensity focused ultrasound (FUS) is an emerging non-invasive and spatially/temporally precise method for modulating the firing rates and patterns of peripheral nerves. This paper describes an image-guided platform for chronic and patient-specific FUS neuromodulation. The system uses custom wearable probes containing separate ultrasound imaging and modulation transducer arrays realized using piezoelectric transducers assembled on a flexible printed circuit board (PCB). Dual-mode probes operating around 4 MHz (imaging) and 1.3 MHz (modulation) were fabricated and tested on tissue phantoms. The resulting B-mode images were analyzed using a template-matching algorithm to estimate the location of the target nerve and then direct the modulation beam toward the target. The ultrasound transmit voltage used to excite the modulation array was optimized in real-time by automatically regulating functional feedback signals (the average rates of emulated muscle twitches detected by an on-board motion sensor) through a proportional and integral (PI) controller, thus providing robustness to inter-subject variability and probe positioning errors. The proposed closed-loop neuromodulation paradigm was experimentally demonstrated in vitro using an active tissue phantom that integrates models of the posterior tibial nerve and nearby blood vessels together with embedded sensors and actuators.</p>","PeriodicalId":94031,"journal":{"name":"IEEE transactions on biomedical circuits and systems","volume":"PP ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-07-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A Wearable Dual-Mode Probe for Image-Guided Closed-Loop Ultrasound Neuromodulation.\",\"authors\":\"Junjun Huan, Vida Pashaei, Steve J A Majerus, Swarup Bhunia, Soumyajit Mandal\",\"doi\":\"10.1109/TBCAS.2024.3425858\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Low-intensity focused ultrasound (FUS) is an emerging non-invasive and spatially/temporally precise method for modulating the firing rates and patterns of peripheral nerves. This paper describes an image-guided platform for chronic and patient-specific FUS neuromodulation. The system uses custom wearable probes containing separate ultrasound imaging and modulation transducer arrays realized using piezoelectric transducers assembled on a flexible printed circuit board (PCB). Dual-mode probes operating around 4 MHz (imaging) and 1.3 MHz (modulation) were fabricated and tested on tissue phantoms. The resulting B-mode images were analyzed using a template-matching algorithm to estimate the location of the target nerve and then direct the modulation beam toward the target. The ultrasound transmit voltage used to excite the modulation array was optimized in real-time by automatically regulating functional feedback signals (the average rates of emulated muscle twitches detected by an on-board motion sensor) through a proportional and integral (PI) controller, thus providing robustness to inter-subject variability and probe positioning errors. The proposed closed-loop neuromodulation paradigm was experimentally demonstrated in vitro using an active tissue phantom that integrates models of the posterior tibial nerve and nearby blood vessels together with embedded sensors and actuators.</p>\",\"PeriodicalId\":94031,\"journal\":{\"name\":\"IEEE transactions on biomedical circuits and systems\",\"volume\":\"PP \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-11\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEEE transactions on biomedical circuits and systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/TBCAS.2024.3425858\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE transactions on biomedical circuits and systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/TBCAS.2024.3425858","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

低强度聚焦超声(FUS)是一种新兴的非侵入性、空间/时间精确调节周围神经发射率和模式的方法。本文介绍了一种用于慢性和特定患者 FUS 神经调控的图像引导平台。该系统使用定制的可穿戴探头,其中包含独立的超声成像和调制换能器阵列,这些阵列使用组装在柔性印刷电路板(PCB)上的压电换能器实现。双模探头的工作频率分别为 4 MHz(成像)和 1.3 MHz(调制),已制作完成并在组织模型上进行了测试。利用模板匹配算法对生成的 B 型图像进行分析,以估计靶神经的位置,然后将调制束导向靶点。用于激励调制阵列的超声波发射电压通过一个比例和积分(PI)控制器自动调节功能反馈信号(由板载运动传感器检测到的模拟肌肉抽搐的平均速率)进行实时优化,从而提供对受试者间变异性和探头定位误差的鲁棒性。所提出的闭环神经调控范例在体外实验中得到了验证,该范例使用了一个主动组织模型,该模型将胫后神经和附近血管的模型与嵌入式传感器和致动器集成在一起。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A Wearable Dual-Mode Probe for Image-Guided Closed-Loop Ultrasound Neuromodulation.

Low-intensity focused ultrasound (FUS) is an emerging non-invasive and spatially/temporally precise method for modulating the firing rates and patterns of peripheral nerves. This paper describes an image-guided platform for chronic and patient-specific FUS neuromodulation. The system uses custom wearable probes containing separate ultrasound imaging and modulation transducer arrays realized using piezoelectric transducers assembled on a flexible printed circuit board (PCB). Dual-mode probes operating around 4 MHz (imaging) and 1.3 MHz (modulation) were fabricated and tested on tissue phantoms. The resulting B-mode images were analyzed using a template-matching algorithm to estimate the location of the target nerve and then direct the modulation beam toward the target. The ultrasound transmit voltage used to excite the modulation array was optimized in real-time by automatically regulating functional feedback signals (the average rates of emulated muscle twitches detected by an on-board motion sensor) through a proportional and integral (PI) controller, thus providing robustness to inter-subject variability and probe positioning errors. The proposed closed-loop neuromodulation paradigm was experimentally demonstrated in vitro using an active tissue phantom that integrates models of the posterior tibial nerve and nearby blood vessels together with embedded sensors and actuators.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信