利用流量数据量,在移动回程 1 毫秒延迟内通过快速光交换实现主动拥塞控制

IF 0.3 Q4 ENGINEERING, ELECTRICAL & ELECTRONIC
Yuka Okamoto;Hirotaka Ujikawa;Kota Asaka;Tatsuya Shimada;Tomoaki Yoshida
{"title":"利用流量数据量,在移动回程 1 毫秒延迟内通过快速光交换实现主动拥塞控制","authors":"Yuka Okamoto;Hirotaka Ujikawa;Kota Asaka;Tatsuya Shimada;Tomoaki Yoshida","doi":"10.23919/comex.2024XBL0055","DOIUrl":null,"url":null,"abstract":"The development and introduction of real-time remote control of robots using mobile NWs is expected. To realize this control, a network configuration in which the User Plane Function (UPF) and Mobile Edge Computing (MEC) are located near the Central Unit (CU) is considered. If traffic exceeds the processing capability of the UPF, there is the concern of congestion. In this paper, we propose and demonstrate a method for obtaining the uplink traffic volume from the CU and predicting the future traffic to switch the optical path and UPF before congestion occurs within the Mobile Backhaul (MBH) delay of 1ms.","PeriodicalId":54101,"journal":{"name":"IEICE Communications Express","volume":"13 7","pages":"256-259"},"PeriodicalIF":0.3000,"publicationDate":"2024-03-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10528223","citationCount":"0","resultStr":"{\"title\":\"Proactive Congestion Control by Fast Optical Switching Within 1-ms Delay at Mobile Backhaul Utilizing Traffic Data Volume\",\"authors\":\"Yuka Okamoto;Hirotaka Ujikawa;Kota Asaka;Tatsuya Shimada;Tomoaki Yoshida\",\"doi\":\"10.23919/comex.2024XBL0055\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The development and introduction of real-time remote control of robots using mobile NWs is expected. To realize this control, a network configuration in which the User Plane Function (UPF) and Mobile Edge Computing (MEC) are located near the Central Unit (CU) is considered. If traffic exceeds the processing capability of the UPF, there is the concern of congestion. In this paper, we propose and demonstrate a method for obtaining the uplink traffic volume from the CU and predicting the future traffic to switch the optical path and UPF before congestion occurs within the Mobile Backhaul (MBH) delay of 1ms.\",\"PeriodicalId\":54101,\"journal\":{\"name\":\"IEICE Communications Express\",\"volume\":\"13 7\",\"pages\":\"256-259\"},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2024-03-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10528223\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"IEICE Communications Express\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10528223/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEICE Communications Express","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10528223/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

摘要

利用移动无线网络对机器人进行实时远程控制的开发和引入令人期待。为了实现这种控制,我们考虑了用户平面功能(UPF)和移动边缘计算(MEC)位于中央单元(CU)附近的网络配置。如果流量超过了 UPF 的处理能力,就会出现拥塞问题。在本文中,我们提出并演示了一种方法,用于从中央单元获取上行链路流量,并预测未来流量,以便在移动回程(MBH)延迟为 1 毫秒时,在拥塞发生之前切换光路和 UPF。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Proactive Congestion Control by Fast Optical Switching Within 1-ms Delay at Mobile Backhaul Utilizing Traffic Data Volume
The development and introduction of real-time remote control of robots using mobile NWs is expected. To realize this control, a network configuration in which the User Plane Function (UPF) and Mobile Edge Computing (MEC) are located near the Central Unit (CU) is considered. If traffic exceeds the processing capability of the UPF, there is the concern of congestion. In this paper, we propose and demonstrate a method for obtaining the uplink traffic volume from the CU and predicting the future traffic to switch the optical path and UPF before congestion occurs within the Mobile Backhaul (MBH) delay of 1ms.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
IEICE Communications Express
IEICE Communications Express ENGINEERING, ELECTRICAL & ELECTRONIC-
自引率
33.30%
发文量
114
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信