S Genoni, F Cinti, M Pilot, M Rossanese, D McCready, M Cantatore
{"title":"用血管内胃肠吻合订书机为猫和小狗进行功能性端对端肠吻合术。","authors":"S Genoni, F Cinti, M Pilot, M Rossanese, D McCready, M Cantatore","doi":"10.1111/jsap.13756","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To investigate the use of endovascular gastrointestinal stapling devices to perform intestinal functional end-to-end stapled anastomosis in small dogs and cats.</p><p><strong>Materials and methods: </strong>Medical records of dogs (≤10 kg) and cats that underwent intestinal resection and functional end-to-end stapled anastomosis with an endovascular gastrointestinal anastomosis (endovascular-GIA) stapling device at five small animal referral centres between April 2014 and September 2023 were retrospectively reviewed. Data including clinical findings, surgical technique, histopathology and complications were collected. A minimum follow-up of 10 days was required. Patients with follow-up of less than 10 days were included if they developed a major complication. Outcome was obtained from assessing the clinical records and contacting the referring veterinarians or owners. Estimated survival was generated according to the Kaplan-Meier method. Differences between survival curves were tested by log-rank test.</p><p><strong>Results: </strong>Twenty-five patients (10 dogs and 15 cats) were included. The median bodyweight was 4.6 kg (range 2.6 to 10 kg). Nine patients were diagnosed with intestinal neoplasia, 16 with non-neoplastic intestinal disease. The median follow-up was 126 days (range 18 to 896 days). Five patients developed minor postoperative complications, including three superficial surgical site infections. No major postoperative complications were reported. Eighteen patients were alive at the end of the study, one patient was lost to follow-up. Kaplan-Meier estimated median survival time was not reached. Survival was significantly longer for patients with non-neoplastic versus neoplastic intestinal.</p><p><strong>Clinical significance: </strong>The study suggests that the use of endovascular gastrointestinal anastomosis staplers is safe and effective to perform intestinal functional end-to-end stapled anastomosis in dogs ≤10 kg and cats.</p>","PeriodicalId":17062,"journal":{"name":"Journal of Small Animal Practice","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-07-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Stapled functional end-to-end intestinal anastomosis with endovascular gastrointestinal anastomosis staplers in cats and small dogs.\",\"authors\":\"S Genoni, F Cinti, M Pilot, M Rossanese, D McCready, M Cantatore\",\"doi\":\"10.1111/jsap.13756\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>To investigate the use of endovascular gastrointestinal stapling devices to perform intestinal functional end-to-end stapled anastomosis in small dogs and cats.</p><p><strong>Materials and methods: </strong>Medical records of dogs (≤10 kg) and cats that underwent intestinal resection and functional end-to-end stapled anastomosis with an endovascular gastrointestinal anastomosis (endovascular-GIA) stapling device at five small animal referral centres between April 2014 and September 2023 were retrospectively reviewed. Data including clinical findings, surgical technique, histopathology and complications were collected. A minimum follow-up of 10 days was required. Patients with follow-up of less than 10 days were included if they developed a major complication. Outcome was obtained from assessing the clinical records and contacting the referring veterinarians or owners. Estimated survival was generated according to the Kaplan-Meier method. Differences between survival curves were tested by log-rank test.</p><p><strong>Results: </strong>Twenty-five patients (10 dogs and 15 cats) were included. The median bodyweight was 4.6 kg (range 2.6 to 10 kg). Nine patients were diagnosed with intestinal neoplasia, 16 with non-neoplastic intestinal disease. The median follow-up was 126 days (range 18 to 896 days). Five patients developed minor postoperative complications, including three superficial surgical site infections. No major postoperative complications were reported. Eighteen patients were alive at the end of the study, one patient was lost to follow-up. Kaplan-Meier estimated median survival time was not reached. Survival was significantly longer for patients with non-neoplastic versus neoplastic intestinal.</p><p><strong>Clinical significance: </strong>The study suggests that the use of endovascular gastrointestinal anastomosis staplers is safe and effective to perform intestinal functional end-to-end stapled anastomosis in dogs ≤10 kg and cats.</p>\",\"PeriodicalId\":17062,\"journal\":{\"name\":\"Journal of Small Animal Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-07-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Small Animal Practice\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1111/jsap.13756\",\"RegionNum\":2,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Small Animal Practice","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/jsap.13756","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
Stapled functional end-to-end intestinal anastomosis with endovascular gastrointestinal anastomosis staplers in cats and small dogs.
Objectives: To investigate the use of endovascular gastrointestinal stapling devices to perform intestinal functional end-to-end stapled anastomosis in small dogs and cats.
Materials and methods: Medical records of dogs (≤10 kg) and cats that underwent intestinal resection and functional end-to-end stapled anastomosis with an endovascular gastrointestinal anastomosis (endovascular-GIA) stapling device at five small animal referral centres between April 2014 and September 2023 were retrospectively reviewed. Data including clinical findings, surgical technique, histopathology and complications were collected. A minimum follow-up of 10 days was required. Patients with follow-up of less than 10 days were included if they developed a major complication. Outcome was obtained from assessing the clinical records and contacting the referring veterinarians or owners. Estimated survival was generated according to the Kaplan-Meier method. Differences between survival curves were tested by log-rank test.
Results: Twenty-five patients (10 dogs and 15 cats) were included. The median bodyweight was 4.6 kg (range 2.6 to 10 kg). Nine patients were diagnosed with intestinal neoplasia, 16 with non-neoplastic intestinal disease. The median follow-up was 126 days (range 18 to 896 days). Five patients developed minor postoperative complications, including three superficial surgical site infections. No major postoperative complications were reported. Eighteen patients were alive at the end of the study, one patient was lost to follow-up. Kaplan-Meier estimated median survival time was not reached. Survival was significantly longer for patients with non-neoplastic versus neoplastic intestinal.
Clinical significance: The study suggests that the use of endovascular gastrointestinal anastomosis staplers is safe and effective to perform intestinal functional end-to-end stapled anastomosis in dogs ≤10 kg and cats.
期刊介绍:
Journal of Small Animal Practice (JSAP) is a monthly peer-reviewed publication integrating clinical research papers and case reports from international sources, covering all aspects of medicine and surgery relating to dogs, cats and other small animals. These papers facilitate the dissemination and implementation of new ideas and techniques relating to clinical veterinary practice, with the ultimate aim of promoting best practice. JSAP publishes high quality original articles, as well as other scientific and educational information. New developments are placed in perspective, encompassing new concepts and peer commentary. The target audience is veterinarians primarily engaged in the practise of small animal medicine and surgery.
In addition to original articles, JSAP will publish invited editorials (relating to a manuscript in the same issue or a topic of current interest), review articles, which provide in-depth discussion of important clinical issues, and other scientific and educational information from around the world.
The final decision on publication of a manuscript rests with the Editorial Board and ultimately with the Editor. All papers, regardless of type, represent the opinion of the authors and not necessarily that of the Editor, the Association or the Publisher.
The Journal of Small Animal Practice is published on behalf of the British Small Animal Veterinary Association and is also the official scientific journal of the World Small Animal Veterinary Association