在实验动物模型中评估表面改性钛种植体的骨附着情况:系统回顾与荟萃分析。

Q2 Dentistry
Priya Saini, Shaveta Sood, Gurparkash Singh Chahal, Ashish Jain
{"title":"在实验动物模型中评估表面改性钛种植体的骨附着情况:系统回顾与荟萃分析。","authors":"Priya Saini, Shaveta Sood, Gurparkash Singh Chahal, Ashish Jain","doi":"10.4103/jisp.jisp_222_22","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the response of peri-implant bone to smooth (machined) surface and surface-modified dental implants in healthy experimental animal models.</p><p><strong>Materials and methods: </strong>Systematic electronic search was done for using PUBMED, SCOPUS, WEB OF SCIENCE, and EMBASE databases for potentially relevant records from the last 20 years. Duplicate screening and data extraction were performed to formulate the evidence tables and meta-analysis following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The outcome criteria were: 1. Bone Implant Contact (BIC) in percentage, 2. Removal Torque Values (RTV) in Ncm, 3. Implant stability Quotient (ISQ), Quality assessment was done using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) guidelines and SYRCLE RoB (Systematic Review Centre for Laboratory Animal Experimentation Risk of Bias) tool.</p><p><strong>Results: </strong>Results were expressed as pooled mean difference for the respective groups viz. sandblasted and acid etched, laser modified, acid etched and anodized surface. The surface modified implants revealed somewhat higher BIC over machined surface (<i>P</i> < 0.01). Forest plot were drawn for all the outcome variables.</p><p><strong>Conclusions: </strong>Within the limitations of this study, the authors found a higher degree of osseointegration pertaining to bone to implant interface, RTV, and implant stability quotient (ISQ) with surface modified procedures which seemed to promote bone formation around peri-implant tissue during the early stages of healing. After analyzing all 37 included publications for the outcome of interest (BIC%, RTV, ISQ), a positive outcome was obtained for both subtractive and additive implant surface modifying procedures over machined implant surfaces when the data were pooled together. More advanced research work on healthy animal models needs to be investigated to review the impact of surface modifications on dental implant osseointegration.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232795/pdf/","citationCount":"0","resultStr":"{\"title\":\"Evaluation of bone apposition on surface modified titanium implant in experimental animal model: A systematic review and meta-analysis.\",\"authors\":\"Priya Saini, Shaveta Sood, Gurparkash Singh Chahal, Ashish Jain\",\"doi\":\"10.4103/jisp.jisp_222_22\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the response of peri-implant bone to smooth (machined) surface and surface-modified dental implants in healthy experimental animal models.</p><p><strong>Materials and methods: </strong>Systematic electronic search was done for using PUBMED, SCOPUS, WEB OF SCIENCE, and EMBASE databases for potentially relevant records from the last 20 years. Duplicate screening and data extraction were performed to formulate the evidence tables and meta-analysis following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The outcome criteria were: 1. Bone Implant Contact (BIC) in percentage, 2. Removal Torque Values (RTV) in Ncm, 3. Implant stability Quotient (ISQ), Quality assessment was done using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) guidelines and SYRCLE RoB (Systematic Review Centre for Laboratory Animal Experimentation Risk of Bias) tool.</p><p><strong>Results: </strong>Results were expressed as pooled mean difference for the respective groups viz. sandblasted and acid etched, laser modified, acid etched and anodized surface. The surface modified implants revealed somewhat higher BIC over machined surface (<i>P</i> < 0.01). Forest plot were drawn for all the outcome variables.</p><p><strong>Conclusions: </strong>Within the limitations of this study, the authors found a higher degree of osseointegration pertaining to bone to implant interface, RTV, and implant stability quotient (ISQ) with surface modified procedures which seemed to promote bone formation around peri-implant tissue during the early stages of healing. After analyzing all 37 included publications for the outcome of interest (BIC%, RTV, ISQ), a positive outcome was obtained for both subtractive and additive implant surface modifying procedures over machined implant surfaces when the data were pooled together. More advanced research work on healthy animal models needs to be investigated to review the impact of surface modifications on dental implant osseointegration.</p>\",\"PeriodicalId\":15890,\"journal\":{\"name\":\"Journal of Indian Society of Periodontology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232795/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Society of Periodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jisp.jisp_222_22\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_222_22","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估健康实验动物模型的种植体周围骨质对光滑(机加工)表面和表面改良的牙科种植体的反应:使用 PUBMED、SCOPUS、WEB OF SCIENCE 和 EMBASE 数据库对过去 20 年中潜在的相关记录进行了系统的电子检索。按照 PRISMA(系统综述和荟萃分析的首选报告项目)指南,进行了重复筛选和数据提取,以编制证据表并进行荟萃分析。结果标准为1.质量评估采用 ARRIVE(动物研究:活体实验报告)指南和 SYRCLE RoB(实验动物实验风险系统综述中心)工具进行:结果:喷砂和酸蚀、激光改性、酸蚀和阳极氧化表面各组的结果以汇总平均差表示。表面改良种植体的 BIC 略高于机加工表面(P < 0.01)。所有结果变量均绘制了森林图:在本研究的局限性范围内,作者发现表面改良程序在骨与种植体界面、RTV和种植体稳定性商数(ISQ)方面具有更高的骨结合度,这似乎在愈合的早期阶段促进了种植体周围组织的骨形成。在对所有 37 篇相关结果(BIC%、RTV、ISQ)的出版物进行分析后发现,如果将数据集中在一起,则减法和加法种植体表面改良术的结果均优于机加工种植体表面。需要对健康动物模型进行更深入的研究,以审查表面改良对牙科种植体骨结合的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of bone apposition on surface modified titanium implant in experimental animal model: A systematic review and meta-analysis.

Purpose: To evaluate the response of peri-implant bone to smooth (machined) surface and surface-modified dental implants in healthy experimental animal models.

Materials and methods: Systematic electronic search was done for using PUBMED, SCOPUS, WEB OF SCIENCE, and EMBASE databases for potentially relevant records from the last 20 years. Duplicate screening and data extraction were performed to formulate the evidence tables and meta-analysis following the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. The outcome criteria were: 1. Bone Implant Contact (BIC) in percentage, 2. Removal Torque Values (RTV) in Ncm, 3. Implant stability Quotient (ISQ), Quality assessment was done using the ARRIVE (Animal Research: Reporting of In Vivo Experiments) guidelines and SYRCLE RoB (Systematic Review Centre for Laboratory Animal Experimentation Risk of Bias) tool.

Results: Results were expressed as pooled mean difference for the respective groups viz. sandblasted and acid etched, laser modified, acid etched and anodized surface. The surface modified implants revealed somewhat higher BIC over machined surface (P < 0.01). Forest plot were drawn for all the outcome variables.

Conclusions: Within the limitations of this study, the authors found a higher degree of osseointegration pertaining to bone to implant interface, RTV, and implant stability quotient (ISQ) with surface modified procedures which seemed to promote bone formation around peri-implant tissue during the early stages of healing. After analyzing all 37 included publications for the outcome of interest (BIC%, RTV, ISQ), a positive outcome was obtained for both subtractive and additive implant surface modifying procedures over machined implant surfaces when the data were pooled together. More advanced research work on healthy animal models needs to be investigated to review the impact of surface modifications on dental implant osseointegration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信