使用短种植体和标准长种植体以及上颌窦提升术进行上颌后部修复,对硬组织和软组织参数进行比较评估。

Q2 Dentistry
Farhan Durrani, S M Karthickraj, Fouzia Imran, Shweta Ahlawat, Ekta Kumari, S U Gokila Vani
{"title":"使用短种植体和标准长种植体以及上颌窦提升术进行上颌后部修复,对硬组织和软组织参数进行比较评估。","authors":"Farhan Durrani, S M Karthickraj, Fouzia Imran, Shweta Ahlawat, Ekta Kumari, S U Gokila Vani","doi":"10.4103/jisp.jisp_436_23","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>The objective is to compare and evaluate the hard and soft tissue parameters by using short and standard long implants with sinus lifting in the posterior maxilla.</p><p><strong>Materials and methods: </strong>Eleven patients with complaints of missing upper back teeth were enrolled in the study for implant-supported rehabilitation and were categorized into two groups: Group long (GL): longer implant (>8 mm) placement, preceded by Sinus Augmentation. Group short (GS): short implant (≤8 mm) placement, without sinus augmentation. The primary outcome measured was cumulative survival rate (CSR) in the compromised partial edentulous posterior maxilla. Secondary outcomes measured were implant stability (IS), marginal bone level alterations (MBL), pocket probing depth (PPD), crown-to-implant ratio, and any complications.</p><p><strong>Results: </strong>The difference in CSR between the groups was not statistically significant (<i>P</i> = 0.317). High stability was achieved immediately after the placement of the implants, in both groups (GS: 64 ± 4.07, GL: 65.58 ± 9.75); this difference in the mean ISQ (IS quotients) values was not found to be statistically significant at implant placement (<i>P</i> = 0.7). The mean MBL reported in the study at the end of 12 months of prosthesis function was - 0.762 ± 0.48 mm and - 0.7 ± 0.34 mm for GS and GL, respectively. The mean PPD measurements in GS and GL groups were 1.917 ± 0.68 mm and 1.833 ± 0.38 mm, respectively, and it was not statistically significant (<i>P</i> = 0.8).</p><p><strong>Conclusion: </strong>Within the limitations of the present study, the obtained results indicate that short implants provided a similar clinical and radiographic performance compared to long implants placed in combination with a sinus augmentation procedure (lateral window) up to 12 months after prosthetic loading.</p>","PeriodicalId":15890,"journal":{"name":"Journal of Indian Society of Periodontology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232800/pdf/","citationCount":"0","resultStr":"{\"title\":\"Comparative evaluation of hard and soft tissue parameters by using short implants and standard long implants with sinus lift for prosthetic rehabilitation of posterior maxilla.\",\"authors\":\"Farhan Durrani, S M Karthickraj, Fouzia Imran, Shweta Ahlawat, Ekta Kumari, S U Gokila Vani\",\"doi\":\"10.4103/jisp.jisp_436_23\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>The objective is to compare and evaluate the hard and soft tissue parameters by using short and standard long implants with sinus lifting in the posterior maxilla.</p><p><strong>Materials and methods: </strong>Eleven patients with complaints of missing upper back teeth were enrolled in the study for implant-supported rehabilitation and were categorized into two groups: Group long (GL): longer implant (>8 mm) placement, preceded by Sinus Augmentation. Group short (GS): short implant (≤8 mm) placement, without sinus augmentation. The primary outcome measured was cumulative survival rate (CSR) in the compromised partial edentulous posterior maxilla. Secondary outcomes measured were implant stability (IS), marginal bone level alterations (MBL), pocket probing depth (PPD), crown-to-implant ratio, and any complications.</p><p><strong>Results: </strong>The difference in CSR between the groups was not statistically significant (<i>P</i> = 0.317). High stability was achieved immediately after the placement of the implants, in both groups (GS: 64 ± 4.07, GL: 65.58 ± 9.75); this difference in the mean ISQ (IS quotients) values was not found to be statistically significant at implant placement (<i>P</i> = 0.7). The mean MBL reported in the study at the end of 12 months of prosthesis function was - 0.762 ± 0.48 mm and - 0.7 ± 0.34 mm for GS and GL, respectively. The mean PPD measurements in GS and GL groups were 1.917 ± 0.68 mm and 1.833 ± 0.38 mm, respectively, and it was not statistically significant (<i>P</i> = 0.8).</p><p><strong>Conclusion: </strong>Within the limitations of the present study, the obtained results indicate that short implants provided a similar clinical and radiographic performance compared to long implants placed in combination with a sinus augmentation procedure (lateral window) up to 12 months after prosthetic loading.</p>\",\"PeriodicalId\":15890,\"journal\":{\"name\":\"Journal of Indian Society of Periodontology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11232800/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Indian Society of Periodontology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4103/jisp.jisp_436_23\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/4 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Indian Society of Periodontology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4103/jisp.jisp_436_23","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0

摘要

目的目的是比较和评估在上颌后牙使用短种植体和标准长种植体并进行上颌窦提升的硬组织和软组织参数:将 11 名主诉上后牙缺失的患者纳入研究,进行种植体支持的康复治疗,并将其分为两组:长组(GL):植入较长的种植体(>8毫米),并在植入前进行窦扩增术。短种植体组(GS):植入短种植体(≤8 毫米),不进行上颌窦扩增。测量的主要结果是受损部分无牙颌后上颌骨的累积存活率(CSR)。次要测量结果包括种植体稳定性(IS)、边缘骨水平改变(MBL)、袋探查深度(PPD)、冠与种植体比率以及任何并发症:两组的 CSR 差异无统计学意义(P = 0.317)。两组患者在植入种植体后都立即获得了较高的稳定性(GS:64 ± 4.07,GL:65.58 ± 9.75);在植入种植体时,ISQ(IS 商)平均值的差异没有统计学意义(P = 0.7)。研究报告显示,在假体功能 12 个月结束时,GS 和 GL 的平均 MBL 分别为 - 0.762 ± 0.48 mm 和 - 0.7 ± 0.34 mm。GS组和GL组的平均PPD测量值分别为1.917±0.68 mm和1.833±0.38 mm,差异无统计学意义(P = 0.8):在本研究的局限性范围内,所获得的结果表明,与长种植体相比,短种植体在修复体植入后12个月内的临床和放射学表现与长种植体相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Comparative evaluation of hard and soft tissue parameters by using short implants and standard long implants with sinus lift for prosthetic rehabilitation of posterior maxilla.

Objective: The objective is to compare and evaluate the hard and soft tissue parameters by using short and standard long implants with sinus lifting in the posterior maxilla.

Materials and methods: Eleven patients with complaints of missing upper back teeth were enrolled in the study for implant-supported rehabilitation and were categorized into two groups: Group long (GL): longer implant (>8 mm) placement, preceded by Sinus Augmentation. Group short (GS): short implant (≤8 mm) placement, without sinus augmentation. The primary outcome measured was cumulative survival rate (CSR) in the compromised partial edentulous posterior maxilla. Secondary outcomes measured were implant stability (IS), marginal bone level alterations (MBL), pocket probing depth (PPD), crown-to-implant ratio, and any complications.

Results: The difference in CSR between the groups was not statistically significant (P = 0.317). High stability was achieved immediately after the placement of the implants, in both groups (GS: 64 ± 4.07, GL: 65.58 ± 9.75); this difference in the mean ISQ (IS quotients) values was not found to be statistically significant at implant placement (P = 0.7). The mean MBL reported in the study at the end of 12 months of prosthesis function was - 0.762 ± 0.48 mm and - 0.7 ± 0.34 mm for GS and GL, respectively. The mean PPD measurements in GS and GL groups were 1.917 ± 0.68 mm and 1.833 ± 0.38 mm, respectively, and it was not statistically significant (P = 0.8).

Conclusion: Within the limitations of the present study, the obtained results indicate that short implants provided a similar clinical and radiographic performance compared to long implants placed in combination with a sinus augmentation procedure (lateral window) up to 12 months after prosthetic loading.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
87
审稿时长
44 weeks
期刊介绍: The Journal of Indian Society of Periodontology publishes original scientific articles to support practice , education and research in the dental specialty of periodontology and oral implantology. Journal of Indian Society of Periodontology (JISP), is the official publication of the Society and is managed and brought out by the Editor of the society. The journal is published Bimonthly with special issues being brought out for specific occasions. The ISP had a bulletin as its publication for a large number of years and was enhanced as a Journal a few years ago
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信