双线性阵列相机的测量系统和远程校准技术研究

IF 1 4区 工程技术 Q4 INSTRUMENTS & INSTRUMENTATION
Bin Feng, Zaiming Liu, Haofei Zhang, Haozhe Fan
{"title":"双线性阵列相机的测量系统和远程校准技术研究","authors":"Bin Feng, Zaiming Liu, Haofei Zhang, Haozhe Fan","doi":"10.2478/msr-2024-0015","DOIUrl":null,"url":null,"abstract":"In order to accurately measure the flight trajectory of the projectile in a long-distance target range, it is important to establish a vertical target measurement system with a two-line array camera at several positions along the range. In the present work, a calibration system using dual theodolites is proposed to calibrate the vertical target measurement system of a dual linear array camera at different positions along a long target range. The present study investigates the principle of intersection measurement in the vertical target measurement system with a double linear array camera and presents the projectile’s target coordinate measurement formula. The calibration method of the measurement system is developed based on an analysis of the parameters in the projectile coordinate measurement formula. The calibration method only requires calibration of the camera’s distortion coefficient, the optical axis angle, and the principal point, ensuring a simplified and expedited calibration process. After calibration, the vertical target measurement system with a 3 m × 3 m measurement area is simulated and analyzed, yielding an error distribution diagram and identifying the factors that influence the measurement accuracy of the projectile’s target coordinates.","PeriodicalId":49848,"journal":{"name":"Measurement Science Review","volume":"1 1","pages":""},"PeriodicalIF":1.0000,"publicationDate":"2024-07-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Research on the Measurement System and Remote Calibration Technology of a Dual Linear Array Camera\",\"authors\":\"Bin Feng, Zaiming Liu, Haofei Zhang, Haozhe Fan\",\"doi\":\"10.2478/msr-2024-0015\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In order to accurately measure the flight trajectory of the projectile in a long-distance target range, it is important to establish a vertical target measurement system with a two-line array camera at several positions along the range. In the present work, a calibration system using dual theodolites is proposed to calibrate the vertical target measurement system of a dual linear array camera at different positions along a long target range. The present study investigates the principle of intersection measurement in the vertical target measurement system with a double linear array camera and presents the projectile’s target coordinate measurement formula. The calibration method of the measurement system is developed based on an analysis of the parameters in the projectile coordinate measurement formula. The calibration method only requires calibration of the camera’s distortion coefficient, the optical axis angle, and the principal point, ensuring a simplified and expedited calibration process. After calibration, the vertical target measurement system with a 3 m × 3 m measurement area is simulated and analyzed, yielding an error distribution diagram and identifying the factors that influence the measurement accuracy of the projectile’s target coordinates.\",\"PeriodicalId\":49848,\"journal\":{\"name\":\"Measurement Science Review\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":1.0000,\"publicationDate\":\"2024-07-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Measurement Science Review\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.2478/msr-2024-0015\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"INSTRUMENTS & INSTRUMENTATION\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Measurement Science Review","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.2478/msr-2024-0015","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0

摘要

为了精确测量远距离靶场中弹丸的飞行轨迹,必须在靶场沿线的多个位置使用双线阵相机建立垂直目标测量系统。本研究提出了一种使用双经纬仪的校准系统,用于校准双线阵相机在长靶场不同位置的垂直目标测量系统。本研究探讨了双线性阵列相机垂直目标测量系统的交点测量原理,并提出了弹丸目标坐标测量公式。在分析弹丸坐标测量公式参数的基础上,提出了测量系统的校准方法。该校准方法只需校准摄像机的畸变系数、光轴角度和主点,确保了校准过程的简化和快速。校准后,对测量面积为 3 m × 3 m 的垂直目标测量系统进行模拟分析,得出误差分布图,并确定了影响弹丸目标坐标测量精度的因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Research on the Measurement System and Remote Calibration Technology of a Dual Linear Array Camera
In order to accurately measure the flight trajectory of the projectile in a long-distance target range, it is important to establish a vertical target measurement system with a two-line array camera at several positions along the range. In the present work, a calibration system using dual theodolites is proposed to calibrate the vertical target measurement system of a dual linear array camera at different positions along a long target range. The present study investigates the principle of intersection measurement in the vertical target measurement system with a double linear array camera and presents the projectile’s target coordinate measurement formula. The calibration method of the measurement system is developed based on an analysis of the parameters in the projectile coordinate measurement formula. The calibration method only requires calibration of the camera’s distortion coefficient, the optical axis angle, and the principal point, ensuring a simplified and expedited calibration process. After calibration, the vertical target measurement system with a 3 m × 3 m measurement area is simulated and analyzed, yielding an error distribution diagram and identifying the factors that influence the measurement accuracy of the projectile’s target coordinates.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Measurement Science Review
Measurement Science Review INSTRUMENTS & INSTRUMENTATION-
CiteScore
2.00
自引率
11.10%
发文量
37
审稿时长
4.8 months
期刊介绍: - theory of measurement - mathematical processing of measured data - measurement uncertainty minimisation - statistical methods in data evaluation and modelling - measurement as an interdisciplinary activity - measurement science in education - medical imaging methods, image processing - biosignal measurement, processing and analysis - model based biomeasurements - neural networks in biomeasurement - telemeasurement in biomedicine - measurement in nanomedicine - measurement of basic physical quantities - magnetic and electric fields measurements - measurement of geometrical and mechanical quantities - optical measuring methods - electromagnetic compatibility - measurement in material science
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信