Ziwei Duan, Jialei Han, Yadong Liu, Xinyu Zhao, Bo Wang, Shuaishuai Cao and Dalin Wu
{"title":"具有雪人状 Janus 纳米结构的聚合物 1H/19F 双模态磁共振成像造影剂。","authors":"Ziwei Duan, Jialei Han, Yadong Liu, Xinyu Zhao, Bo Wang, Shuaishuai Cao and Dalin Wu","doi":"10.1039/D4TB00923A","DOIUrl":null,"url":null,"abstract":"<p >Magnetic resonance imaging (MRI) has emerged as a pivotal tool in contemporary medical diagnostics, offering non-invasive and high-resolution visualization of internal structures. Contrast agents are essential for enhancing MRI resolution, accurate lesion detection, and early pathology identification. While gadolinium-based contrast agents are widely used in clinics, safety concerns have prompted exploration of metal-free alternatives, including fluorine and nitroxide radical-based MRI contrast agents. Fluorine-containing compounds exhibit excellent MRI capabilities, with <small><sup>19</sup></small>F MRI providing enhanced resolution and quantitative assessment. Nitroxide radicals, such as PROXYL and TEMPO, offer paramagnetic properties for MRI contrast. Despite their versatility, nitroxide radicals suffer from lower relaxivity values (<em>r</em><small><sub>1</sub></small>) compared to gadolinium. Dual-modal imaging, combining <small><sup>1</sup></small>H and <small><sup>19</sup></small>F MRI, has gained prominence for its comprehensive insights into biological processes and disease states. However, existing dual-modal agents predominantly utilize gadolinium-organic ligands without incorporating nitroxide radicals. Here, we introduce a novel dual-modal MRI contrast agent (J-CA) featuring a Janus asymmetric nanostructure synthesized <em>via</em> seeded emulsion polymerization and post-modification. J-CA demonstrates excellent <em>in vitro</em> and <em>in vivo</em> performance in both <small><sup>19</sup></small>F and <small><sup>1</sup></small>H MRI, with a <em>T</em><small><sub>2</sub></small> relaxation time of 5 ms and an <em>r</em><small><sub>1</sub></small> value of 0.31 mM<small><sup>−1</sup></small> s<small><sup>−1</sup></small>, ensuring dual-modal imaging capability. Moreover, J-CA exhibits superior biocompatibility and organ targeting, making it a promising candidate for precise lesion imaging and disease diagnosis. This work introduces a new avenue for metal-free dual-modal MRI, addressing safety concerns associated with traditional contrast agents.</p>","PeriodicalId":83,"journal":{"name":"Journal of Materials Chemistry B","volume":" 29","pages":" 7090-7102"},"PeriodicalIF":6.1000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"A polymeric 1H/19F dual-modal MRI contrast agent with a snowman-like Janus nanostructure†\",\"authors\":\"Ziwei Duan, Jialei Han, Yadong Liu, Xinyu Zhao, Bo Wang, Shuaishuai Cao and Dalin Wu\",\"doi\":\"10.1039/D4TB00923A\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Magnetic resonance imaging (MRI) has emerged as a pivotal tool in contemporary medical diagnostics, offering non-invasive and high-resolution visualization of internal structures. Contrast agents are essential for enhancing MRI resolution, accurate lesion detection, and early pathology identification. While gadolinium-based contrast agents are widely used in clinics, safety concerns have prompted exploration of metal-free alternatives, including fluorine and nitroxide radical-based MRI contrast agents. Fluorine-containing compounds exhibit excellent MRI capabilities, with <small><sup>19</sup></small>F MRI providing enhanced resolution and quantitative assessment. Nitroxide radicals, such as PROXYL and TEMPO, offer paramagnetic properties for MRI contrast. Despite their versatility, nitroxide radicals suffer from lower relaxivity values (<em>r</em><small><sub>1</sub></small>) compared to gadolinium. Dual-modal imaging, combining <small><sup>1</sup></small>H and <small><sup>19</sup></small>F MRI, has gained prominence for its comprehensive insights into biological processes and disease states. However, existing dual-modal agents predominantly utilize gadolinium-organic ligands without incorporating nitroxide radicals. Here, we introduce a novel dual-modal MRI contrast agent (J-CA) featuring a Janus asymmetric nanostructure synthesized <em>via</em> seeded emulsion polymerization and post-modification. J-CA demonstrates excellent <em>in vitro</em> and <em>in vivo</em> performance in both <small><sup>19</sup></small>F and <small><sup>1</sup></small>H MRI, with a <em>T</em><small><sub>2</sub></small> relaxation time of 5 ms and an <em>r</em><small><sub>1</sub></small> value of 0.31 mM<small><sup>−1</sup></small> s<small><sup>−1</sup></small>, ensuring dual-modal imaging capability. Moreover, J-CA exhibits superior biocompatibility and organ targeting, making it a promising candidate for precise lesion imaging and disease diagnosis. This work introduces a new avenue for metal-free dual-modal MRI, addressing safety concerns associated with traditional contrast agents.</p>\",\"PeriodicalId\":83,\"journal\":{\"name\":\"Journal of Materials Chemistry B\",\"volume\":\" 29\",\"pages\":\" 7090-7102\"},\"PeriodicalIF\":6.1000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Materials Chemistry B\",\"FirstCategoryId\":\"1\",\"ListUrlMain\":\"https://pubs.rsc.org/en/content/articlelanding/2024/tb/d4tb00923a\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Materials Chemistry B","FirstCategoryId":"1","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2024/tb/d4tb00923a","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
A polymeric 1H/19F dual-modal MRI contrast agent with a snowman-like Janus nanostructure†
Magnetic resonance imaging (MRI) has emerged as a pivotal tool in contemporary medical diagnostics, offering non-invasive and high-resolution visualization of internal structures. Contrast agents are essential for enhancing MRI resolution, accurate lesion detection, and early pathology identification. While gadolinium-based contrast agents are widely used in clinics, safety concerns have prompted exploration of metal-free alternatives, including fluorine and nitroxide radical-based MRI contrast agents. Fluorine-containing compounds exhibit excellent MRI capabilities, with 19F MRI providing enhanced resolution and quantitative assessment. Nitroxide radicals, such as PROXYL and TEMPO, offer paramagnetic properties for MRI contrast. Despite their versatility, nitroxide radicals suffer from lower relaxivity values (r1) compared to gadolinium. Dual-modal imaging, combining 1H and 19F MRI, has gained prominence for its comprehensive insights into biological processes and disease states. However, existing dual-modal agents predominantly utilize gadolinium-organic ligands without incorporating nitroxide radicals. Here, we introduce a novel dual-modal MRI contrast agent (J-CA) featuring a Janus asymmetric nanostructure synthesized via seeded emulsion polymerization and post-modification. J-CA demonstrates excellent in vitro and in vivo performance in both 19F and 1H MRI, with a T2 relaxation time of 5 ms and an r1 value of 0.31 mM−1 s−1, ensuring dual-modal imaging capability. Moreover, J-CA exhibits superior biocompatibility and organ targeting, making it a promising candidate for precise lesion imaging and disease diagnosis. This work introduces a new avenue for metal-free dual-modal MRI, addressing safety concerns associated with traditional contrast agents.
期刊介绍:
Journal of Materials Chemistry A, B & C cover high quality studies across all fields of materials chemistry. The journals focus on those theoretical or experimental studies that report new understanding, applications, properties and synthesis of materials. Journal of Materials Chemistry A, B & C are separated by the intended application of the material studied. Broadly, applications in energy and sustainability are of interest to Journal of Materials Chemistry A, applications in biology and medicine are of interest to Journal of Materials Chemistry B, and applications in optical, magnetic and electronic devices are of interest to Journal of Materials Chemistry C.Journal of Materials Chemistry B is a Transformative Journal and Plan S compliant. Example topic areas within the scope of Journal of Materials Chemistry B are listed below. This list is neither exhaustive nor exclusive:
Antifouling coatings
Biocompatible materials
Bioelectronics
Bioimaging
Biomimetics
Biomineralisation
Bionics
Biosensors
Diagnostics
Drug delivery
Gene delivery
Immunobiology
Nanomedicine
Regenerative medicine & Tissue engineering
Scaffolds
Soft robotics
Stem cells
Therapeutic devices