{"title":"用于检测视网膜移位的光学相干断层同色成像:一项验证研究。","authors":"Koby Brosh, Eduardo Roditi, Aditya Bansal, Isabela Martins Melo, Michael J Potter, Rajeev H Muni","doi":"10.1007/s00417-024-06555-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Retinal displacement following rhegmatogenous retinal detachment (RRD) has been associated with inferior functional outcomes. Recent evidence using an overlay technique suggests that fundus-autofluorescence underestimates post-RRD repair retinal displacement. This study aims to validate the overlay technique in normal eyes and to determine its sensitivity and specificity at detecting retinal displacement.</p><p><strong>Methods: </strong>We conducted a retrospective case series involving 66 normal eyes, each with at least two separate infrared (IR) images at different time points. Overlay of the two images was based on manual marking of choroidal and optic nerve head (ONH) landmarks. For each set of two IR images, computer code for homography generated two outputs, flipping view video and an overlay picture. First, validation of choroidal/ONH alignment was performed using the flipping view video to ensure accurate manual markings. Then, two different masked graders (AB + IM) evaluated the overlays for presence of retinal displacement. 16 control eyes following RRD repair with detected retinal displacement on FAF imaging assessed sensitivity and specificity of the technique.</p><p><strong>Results: </strong>94% of overlays were found to be well aligned (62/66). 11 cases exhibited errors on flipping view analysis (choroidal/ONH misalignment). Those 11 cases had a significantly higher rate of retinal displacement (false positives) compared to cases without errors (8/11,72% Vs 54/55,98%,P = 0.001). Sensitivity and specificity of the overlay technique for detecting retinal displacement considering only adequate flipping view cases (n = 55) were calculated as 100% and 98%, respectively.</p><p><strong>Conclusions: </strong>IR overlay emerges as a reliable and valid method for detecting retinal displacement, exhibiting excellent sensitivity and specificity.</p>","PeriodicalId":12795,"journal":{"name":"Graefe’s Archive for Clinical and Experimental Ophthalmology","volume":" ","pages":"3797-3804"},"PeriodicalIF":2.4000,"publicationDate":"2024-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11608164/pdf/","citationCount":"0","resultStr":"{\"title\":\"Optical coherence tomography homography for detection of retinal displacement: a validation study.\",\"authors\":\"Koby Brosh, Eduardo Roditi, Aditya Bansal, Isabela Martins Melo, Michael J Potter, Rajeev H Muni\",\"doi\":\"10.1007/s00417-024-06555-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Retinal displacement following rhegmatogenous retinal detachment (RRD) has been associated with inferior functional outcomes. Recent evidence using an overlay technique suggests that fundus-autofluorescence underestimates post-RRD repair retinal displacement. This study aims to validate the overlay technique in normal eyes and to determine its sensitivity and specificity at detecting retinal displacement.</p><p><strong>Methods: </strong>We conducted a retrospective case series involving 66 normal eyes, each with at least two separate infrared (IR) images at different time points. Overlay of the two images was based on manual marking of choroidal and optic nerve head (ONH) landmarks. For each set of two IR images, computer code for homography generated two outputs, flipping view video and an overlay picture. First, validation of choroidal/ONH alignment was performed using the flipping view video to ensure accurate manual markings. Then, two different masked graders (AB + IM) evaluated the overlays for presence of retinal displacement. 16 control eyes following RRD repair with detected retinal displacement on FAF imaging assessed sensitivity and specificity of the technique.</p><p><strong>Results: </strong>94% of overlays were found to be well aligned (62/66). 11 cases exhibited errors on flipping view analysis (choroidal/ONH misalignment). Those 11 cases had a significantly higher rate of retinal displacement (false positives) compared to cases without errors (8/11,72% Vs 54/55,98%,P = 0.001). Sensitivity and specificity of the overlay technique for detecting retinal displacement considering only adequate flipping view cases (n = 55) were calculated as 100% and 98%, respectively.</p><p><strong>Conclusions: </strong>IR overlay emerges as a reliable and valid method for detecting retinal displacement, exhibiting excellent sensitivity and specificity.</p>\",\"PeriodicalId\":12795,\"journal\":{\"name\":\"Graefe’s Archive for Clinical and Experimental Ophthalmology\",\"volume\":\" \",\"pages\":\"3797-3804\"},\"PeriodicalIF\":2.4000,\"publicationDate\":\"2024-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11608164/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Graefe’s Archive for Clinical and Experimental Ophthalmology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00417-024-06555-1\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe’s Archive for Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-024-06555-1","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/10 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
Optical coherence tomography homography for detection of retinal displacement: a validation study.
Purpose: Retinal displacement following rhegmatogenous retinal detachment (RRD) has been associated with inferior functional outcomes. Recent evidence using an overlay technique suggests that fundus-autofluorescence underestimates post-RRD repair retinal displacement. This study aims to validate the overlay technique in normal eyes and to determine its sensitivity and specificity at detecting retinal displacement.
Methods: We conducted a retrospective case series involving 66 normal eyes, each with at least two separate infrared (IR) images at different time points. Overlay of the two images was based on manual marking of choroidal and optic nerve head (ONH) landmarks. For each set of two IR images, computer code for homography generated two outputs, flipping view video and an overlay picture. First, validation of choroidal/ONH alignment was performed using the flipping view video to ensure accurate manual markings. Then, two different masked graders (AB + IM) evaluated the overlays for presence of retinal displacement. 16 control eyes following RRD repair with detected retinal displacement on FAF imaging assessed sensitivity and specificity of the technique.
Results: 94% of overlays were found to be well aligned (62/66). 11 cases exhibited errors on flipping view analysis (choroidal/ONH misalignment). Those 11 cases had a significantly higher rate of retinal displacement (false positives) compared to cases without errors (8/11,72% Vs 54/55,98%,P = 0.001). Sensitivity and specificity of the overlay technique for detecting retinal displacement considering only adequate flipping view cases (n = 55) were calculated as 100% and 98%, respectively.
Conclusions: IR overlay emerges as a reliable and valid method for detecting retinal displacement, exhibiting excellent sensitivity and specificity.
期刊介绍:
Graefe''s Archive for Clinical and Experimental Ophthalmology is a distinguished international journal that presents original clinical reports and clini-cally relevant experimental studies. Founded in 1854 by Albrecht von Graefe to serve as a source of useful clinical information and a stimulus for discussion, the journal has published articles by leading ophthalmologists and vision research scientists for more than a century. With peer review by an international Editorial Board and prompt English-language publication, Graefe''s Archive provides rapid dissemination of clinical and clinically related experimental information.