自动立体 3D 观赏会改变近视眼晶状体的尺寸。

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Ophthalmic and Physiological Optics Pub Date : 2024-09-01 Epub Date: 2024-07-09 DOI:10.1111/opo.13361
Yangyi Huang, Weijung Ten, Biyun Zhan, Yang Shen, Bingqing Sun, Haipeng Xu, Xingtao Zhou
{"title":"自动立体 3D 观赏会改变近视眼晶状体的尺寸。","authors":"Yangyi Huang, Weijung Ten, Biyun Zhan, Yang Shen, Bingqing Sun, Haipeng Xu, Xingtao Zhou","doi":"10.1111/opo.13361","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Autostereoscopic displays have become increasingly common, but their impact on ocular dimensions remains unknown. We sought to identify changes in the crystalline lens dimensions induced by autostereoscopic three-dimensional (3D) viewing.</p><p><strong>Methods: </strong>Forty young adults (age: 22.6 ± 2.0 years, male/female: 15/25) were consecutively enrolled and randomly divided into two groups (3D and two-dimensional [2D] viewing groups) to watch a 30-min movie clip displayed in 3D or 2D mode on a tablet computer. The lens thickness (LT), diameter, curvature, decentration and tilt were measured with anterior segment optical coherence tomography under both non-accommodating (static) and accommodating conditions.</p><p><strong>Results: </strong>In the static condition, the LT decreased by 0.03 ± 0.03 mm (p < 0.001) and the anterior radius of curvature (ARC) increased by 0.49 ± 0.59 mm (p = 0.001) post-3D viewing. In contrast, following 2D viewing, the ARC decreased by 0.23 ± 0.25 mm (p = 0.001). Additionally, the increase in the steep ARC post-3D viewing was greater in high-myopic eyes than low to moderate myopic eyes (p = 0.04). When comparing the accommodative with the static (non-accommodative) condition, for 3D viewing the lens decentration decreased (-0.03 ± 0.05 mm, p = 0.02); while for 2D viewing, the posterior curvature radius (-0.14 ± 0.20 mm, p = 0.006) and diameter (-0.13 ± 0.20 mm, p = 0.01) decreased.</p><p><strong>Conclusions: </strong>Viewing with the autostereoscopic 3D tablet could temporally decrease the thickness and curvature of the lens under non-accommodating conditions. However, its long-term effect requires further exploration.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":"1309-1318"},"PeriodicalIF":2.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Autostereoscopic 3D viewing can change the dimensions of the crystalline lens in myopes.\",\"authors\":\"Yangyi Huang, Weijung Ten, Biyun Zhan, Yang Shen, Bingqing Sun, Haipeng Xu, Xingtao Zhou\",\"doi\":\"10.1111/opo.13361\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Autostereoscopic displays have become increasingly common, but their impact on ocular dimensions remains unknown. We sought to identify changes in the crystalline lens dimensions induced by autostereoscopic three-dimensional (3D) viewing.</p><p><strong>Methods: </strong>Forty young adults (age: 22.6 ± 2.0 years, male/female: 15/25) were consecutively enrolled and randomly divided into two groups (3D and two-dimensional [2D] viewing groups) to watch a 30-min movie clip displayed in 3D or 2D mode on a tablet computer. The lens thickness (LT), diameter, curvature, decentration and tilt were measured with anterior segment optical coherence tomography under both non-accommodating (static) and accommodating conditions.</p><p><strong>Results: </strong>In the static condition, the LT decreased by 0.03 ± 0.03 mm (p < 0.001) and the anterior radius of curvature (ARC) increased by 0.49 ± 0.59 mm (p = 0.001) post-3D viewing. In contrast, following 2D viewing, the ARC decreased by 0.23 ± 0.25 mm (p = 0.001). Additionally, the increase in the steep ARC post-3D viewing was greater in high-myopic eyes than low to moderate myopic eyes (p = 0.04). When comparing the accommodative with the static (non-accommodative) condition, for 3D viewing the lens decentration decreased (-0.03 ± 0.05 mm, p = 0.02); while for 2D viewing, the posterior curvature radius (-0.14 ± 0.20 mm, p = 0.006) and diameter (-0.13 ± 0.20 mm, p = 0.01) decreased.</p><p><strong>Conclusions: </strong>Viewing with the autostereoscopic 3D tablet could temporally decrease the thickness and curvature of the lens under non-accommodating conditions. However, its long-term effect requires further exploration.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":\" \",\"pages\":\"1309-1318\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13361\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/9 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13361","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/9 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

目的:自动立体显示器已变得越来越普遍,但其对眼部尺寸的影响仍不为人知。我们试图确定自动立体三维(3D)观看引起的晶状体尺寸变化:连续招募 40 名年轻成年人(年龄:22.6 ± 2.0 岁,男女比例:15/25),将他们随机分为两组(三维观看组和二维观看组),在平板电脑上观看以三维或二维模式显示的 30 分钟电影片段。在非适应(静态)和适应条件下,用眼前节光学相干断层扫描测量晶状体厚度(LT)、直径、曲率、散光和倾斜度:结果:在静态条件下,LT 下降了 0.03 ± 0.03 毫米(P在非适应条件下,使用自动立体 3D 平板电脑观看可在时间上减少晶状体的厚度和曲率。但是,其长期效果还需要进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Autostereoscopic 3D viewing can change the dimensions of the crystalline lens in myopes.

Purpose: Autostereoscopic displays have become increasingly common, but their impact on ocular dimensions remains unknown. We sought to identify changes in the crystalline lens dimensions induced by autostereoscopic three-dimensional (3D) viewing.

Methods: Forty young adults (age: 22.6 ± 2.0 years, male/female: 15/25) were consecutively enrolled and randomly divided into two groups (3D and two-dimensional [2D] viewing groups) to watch a 30-min movie clip displayed in 3D or 2D mode on a tablet computer. The lens thickness (LT), diameter, curvature, decentration and tilt were measured with anterior segment optical coherence tomography under both non-accommodating (static) and accommodating conditions.

Results: In the static condition, the LT decreased by 0.03 ± 0.03 mm (p < 0.001) and the anterior radius of curvature (ARC) increased by 0.49 ± 0.59 mm (p = 0.001) post-3D viewing. In contrast, following 2D viewing, the ARC decreased by 0.23 ± 0.25 mm (p = 0.001). Additionally, the increase in the steep ARC post-3D viewing was greater in high-myopic eyes than low to moderate myopic eyes (p = 0.04). When comparing the accommodative with the static (non-accommodative) condition, for 3D viewing the lens decentration decreased (-0.03 ± 0.05 mm, p = 0.02); while for 2D viewing, the posterior curvature radius (-0.14 ± 0.20 mm, p = 0.006) and diameter (-0.13 ± 0.20 mm, p = 0.01) decreased.

Conclusions: Viewing with the autostereoscopic 3D tablet could temporally decrease the thickness and curvature of the lens under non-accommodating conditions. However, its long-term effect requires further exploration.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.10
自引率
13.80%
发文量
135
审稿时长
6-12 weeks
期刊介绍: Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry. OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信