Jake M Lesinski, Nathan K Khosla, Carolina Paganini, Bo Verberckmoes, Heleen Vermandere, Andrew J deMello, Daniel A Richards
{"title":"关于 CRISPR-Cas 检测的 FRETting:双通道报告降低了检测限和结果时间。","authors":"Jake M Lesinski, Nathan K Khosla, Carolina Paganini, Bo Verberckmoes, Heleen Vermandere, Andrew J deMello, Daniel A Richards","doi":"10.1021/acssensors.4c00652","DOIUrl":null,"url":null,"abstract":"<p><p><u>C</u>lustered <u>R</u>egularly <u>I</u>nterspaced <u>S</u>hort <u>P</u>alindromic <u>R</u>epeats-<u>C</u>RISPR-<u>A</u>ssociated <u>P</u>rotein (CRISPR-Cas) systems have evolved several mechanisms to specifically target foreign DNA. These properties have made them attractive as biosensors. The primary drawback associated with contemporary CRISPR-Cas biosensors is their weak signaling capacity, which is typically compensated for by coupling the CRISPR-Cas systems to nucleic acid amplification. An alternative strategy to improve signaling capacity is to engineer the reporter, i.e., design new signal-generating substrates for Cas proteins. Unfortunately, due to their reliance on custom synthesis, most of these engineered reporter substrates are inaccessible to many researchers. Herein, we investigate a substrate based on a fluorescein (FAM)-tetramethylrhodamine (TAMRA) Förster resonant energy-transfer (FRET) pair that functions as a seamless \"drop-in\" replacement for existing reporters, without the need to change any other aspect of a CRISPR-Cas12a-based assay. The reporter is readily available and employs FRET to produce two signals upon cleavage by Cas12a. The use of both signals in a ratiometric manner provides for improved assay performance and a decreased time-to-result for several CRISPR-Cas12a assays when compared to a traditional FAM-Black Hole Quencher (BHQ) quench-based reporter. We comprehensively characterize this reporter to better understand the reasons for the improved signaling capacity and benchmark it against the current standard CRISPR-Cas reporter. Finally, to showcase the real-world utility of the reporter, we employ it in a <u>R</u>ecombinase <u>P</u>olymerase <u>A</u>mplification (RPA)-CRISPR-Cas12a <u>D</u>NA <u>E</u>ndonuclease-<u>T</u>arget<u>e</u>d <u>C</u>RISPR <u>T</u>rans <u>R</u>eporter (DETECTR) assay to detect <i>Human papillomavirus</i> in patient-derived samples.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":null,"pages":null},"PeriodicalIF":8.2000,"publicationDate":"2024-07-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11287743/pdf/","citationCount":"0","resultStr":"{\"title\":\"FRETting about CRISPR-Cas Assays: Dual-Channel Reporting Lowers Detection Limits and Times-to-Result.\",\"authors\":\"Jake M Lesinski, Nathan K Khosla, Carolina Paganini, Bo Verberckmoes, Heleen Vermandere, Andrew J deMello, Daniel A Richards\",\"doi\":\"10.1021/acssensors.4c00652\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><u>C</u>lustered <u>R</u>egularly <u>I</u>nterspaced <u>S</u>hort <u>P</u>alindromic <u>R</u>epeats-<u>C</u>RISPR-<u>A</u>ssociated <u>P</u>rotein (CRISPR-Cas) systems have evolved several mechanisms to specifically target foreign DNA. These properties have made them attractive as biosensors. The primary drawback associated with contemporary CRISPR-Cas biosensors is their weak signaling capacity, which is typically compensated for by coupling the CRISPR-Cas systems to nucleic acid amplification. An alternative strategy to improve signaling capacity is to engineer the reporter, i.e., design new signal-generating substrates for Cas proteins. Unfortunately, due to their reliance on custom synthesis, most of these engineered reporter substrates are inaccessible to many researchers. Herein, we investigate a substrate based on a fluorescein (FAM)-tetramethylrhodamine (TAMRA) Förster resonant energy-transfer (FRET) pair that functions as a seamless \\\"drop-in\\\" replacement for existing reporters, without the need to change any other aspect of a CRISPR-Cas12a-based assay. The reporter is readily available and employs FRET to produce two signals upon cleavage by Cas12a. The use of both signals in a ratiometric manner provides for improved assay performance and a decreased time-to-result for several CRISPR-Cas12a assays when compared to a traditional FAM-Black Hole Quencher (BHQ) quench-based reporter. We comprehensively characterize this reporter to better understand the reasons for the improved signaling capacity and benchmark it against the current standard CRISPR-Cas reporter. Finally, to showcase the real-world utility of the reporter, we employ it in a <u>R</u>ecombinase <u>P</u>olymerase <u>A</u>mplification (RPA)-CRISPR-Cas12a <u>D</u>NA <u>E</u>ndonuclease-<u>T</u>arget<u>e</u>d <u>C</u>RISPR <u>T</u>rans <u>R</u>eporter (DETECTR) assay to detect <i>Human papillomavirus</i> in patient-derived samples.</p>\",\"PeriodicalId\":24,\"journal\":{\"name\":\"ACS Sensors\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":8.2000,\"publicationDate\":\"2024-07-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11287743/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Sensors\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1021/acssensors.4c00652\",\"RegionNum\":1,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.4c00652","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/8 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
FRETting about CRISPR-Cas Assays: Dual-Channel Reporting Lowers Detection Limits and Times-to-Result.
Clustered Regularly Interspaced Short Palindromic Repeats-CRISPR-Associated Protein (CRISPR-Cas) systems have evolved several mechanisms to specifically target foreign DNA. These properties have made them attractive as biosensors. The primary drawback associated with contemporary CRISPR-Cas biosensors is their weak signaling capacity, which is typically compensated for by coupling the CRISPR-Cas systems to nucleic acid amplification. An alternative strategy to improve signaling capacity is to engineer the reporter, i.e., design new signal-generating substrates for Cas proteins. Unfortunately, due to their reliance on custom synthesis, most of these engineered reporter substrates are inaccessible to many researchers. Herein, we investigate a substrate based on a fluorescein (FAM)-tetramethylrhodamine (TAMRA) Förster resonant energy-transfer (FRET) pair that functions as a seamless "drop-in" replacement for existing reporters, without the need to change any other aspect of a CRISPR-Cas12a-based assay. The reporter is readily available and employs FRET to produce two signals upon cleavage by Cas12a. The use of both signals in a ratiometric manner provides for improved assay performance and a decreased time-to-result for several CRISPR-Cas12a assays when compared to a traditional FAM-Black Hole Quencher (BHQ) quench-based reporter. We comprehensively characterize this reporter to better understand the reasons for the improved signaling capacity and benchmark it against the current standard CRISPR-Cas reporter. Finally, to showcase the real-world utility of the reporter, we employ it in a Recombinase Polymerase Amplification (RPA)-CRISPR-Cas12a DNA Endonuclease-Targeted CRISPR Trans Reporter (DETECTR) assay to detect Human papillomavirus in patient-derived samples.
期刊介绍:
ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.