{"title":"利用盐析辅助液液萃取技术从微量人体血清中定量检测头孢曲松的分析方法。","authors":"Yuji Mukai,&nbsp;Narushi Sugii,&nbsp;Kosuke Doki,&nbsp;Masato Homma","doi":"10.1002/bmc.5955","DOIUrl":null,"url":null,"abstract":"<p>Ceftriaxone (CTRX) is a commonly used cephalosporin antibiotic. It is suggested that monitoring plasma/serum concentrations is helpful for its safe use. This study aimed to develop and validate an analytical method for measuring CTRX concentrations in human serum according to International Conference on Harmonization guideline M10. Ten microliters of serum sample was purified using a salting-out assisted liquid–liquid extraction procedure with magnesium sulfate. The upper layer was then diluted threefold and analyzed using a liquid chromatography–tandem mass spectrometry-based method with a total run time of 12 min. The linear calibration curve was obtained over the concentration range 5–500 μg/ml. The within-run accuracy varied from 0.2 to 6.5%, and the precision was ≤8.0%. The between-run accuracy and precision ranged from 0.7% to 5.6% and ≤6.4%, respectively. Significant carryover was resolved by injecting four blanks after high-concentration CTRX samples. The recovery rates from spiked serum at low and high concentrations were 44.4 and 43.4%, respectively. Other factors, including selectivity, matrix effects, stability, dilution integrity and reinjection reproducibility also met the acceptance criteria. Serum concentrations in 14 samples obtained from two participants receiving 2 g/day of CTRX were successfully determined using this method.</p>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"38 9","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2024-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An analytical method using salting-out assisted liquid–liquid extraction to quantify ceftriaxone from micro volumes of human serum\",\"authors\":\"Yuji Mukai,&nbsp;Narushi Sugii,&nbsp;Kosuke Doki,&nbsp;Masato Homma\",\"doi\":\"10.1002/bmc.5955\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Ceftriaxone (CTRX) is a commonly used cephalosporin antibiotic. It is suggested that monitoring plasma/serum concentrations is helpful for its safe use. This study aimed to develop and validate an analytical method for measuring CTRX concentrations in human serum according to International Conference on Harmonization guideline M10. Ten microliters of serum sample was purified using a salting-out assisted liquid–liquid extraction procedure with magnesium sulfate. The upper layer was then diluted threefold and analyzed using a liquid chromatography–tandem mass spectrometry-based method with a total run time of 12 min. The linear calibration curve was obtained over the concentration range 5–500 μg/ml. The within-run accuracy varied from 0.2 to 6.5%, and the precision was ≤8.0%. The between-run accuracy and precision ranged from 0.7% to 5.6% and ≤6.4%, respectively. Significant carryover was resolved by injecting four blanks after high-concentration CTRX samples. The recovery rates from spiked serum at low and high concentrations were 44.4 and 43.4%, respectively. Other factors, including selectivity, matrix effects, stability, dilution integrity and reinjection reproducibility also met the acceptance criteria. Serum concentrations in 14 samples obtained from two participants receiving 2 g/day of CTRX were successfully determined using this method.</p>\",\"PeriodicalId\":8861,\"journal\":{\"name\":\"Biomedical Chromatography\",\"volume\":\"38 9\",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-07-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedical Chromatography\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/bmc.5955\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.5955","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

摘要

头孢曲松(CTRX)是一种常用的头孢菌素类抗生素。建议监测血浆/血清浓度有助于其安全使用。本研究旨在根据国际协调会议指南 M10,开发并验证一种测量人血清中 CTRX 浓度的分析方法。采用硫酸镁盐析辅助液液萃取法纯化 10 微升血清样品。然后将上层样品稀释三倍,采用液相色谱-串联质谱法进行分析,总运行时间为 12 分钟。在 5-500 μg/ml 的浓度范围内获得了线性校正曲线。在5-500 μg/ml的浓度范围内线性关系良好(r2>0.9),内标法定量准确度为0.2%~6.5%,精密度为≤8.0%。运行间准确度和精密度分别为 0.7% 至 5.6% 和 ≤6.4%。通过在高浓度 CTRX 样品后注入四个空白样品,解决了明显的携带问题。低浓度和高浓度加标血清的回收率分别为 44.4% 和 43.4%。其他因素,包括选择性、基质效应、稳定性、稀释完整性和再注射重现性,也都符合验收标准。使用该方法成功测定了两名每天服用 2 克 CTRX 的参试者 14 份样本中的血清浓度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An analytical method using salting-out assisted liquid–liquid extraction to quantify ceftriaxone from micro volumes of human serum

Ceftriaxone (CTRX) is a commonly used cephalosporin antibiotic. It is suggested that monitoring plasma/serum concentrations is helpful for its safe use. This study aimed to develop and validate an analytical method for measuring CTRX concentrations in human serum according to International Conference on Harmonization guideline M10. Ten microliters of serum sample was purified using a salting-out assisted liquid–liquid extraction procedure with magnesium sulfate. The upper layer was then diluted threefold and analyzed using a liquid chromatography–tandem mass spectrometry-based method with a total run time of 12 min. The linear calibration curve was obtained over the concentration range 5–500 μg/ml. The within-run accuracy varied from 0.2 to 6.5%, and the precision was ≤8.0%. The between-run accuracy and precision ranged from 0.7% to 5.6% and ≤6.4%, respectively. Significant carryover was resolved by injecting four blanks after high-concentration CTRX samples. The recovery rates from spiked serum at low and high concentrations were 44.4 and 43.4%, respectively. Other factors, including selectivity, matrix effects, stability, dilution integrity and reinjection reproducibility also met the acceptance criteria. Serum concentrations in 14 samples obtained from two participants receiving 2 g/day of CTRX were successfully determined using this method.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信