可穿戴低强度连续超声波对迟发性肌肉酸痛期间肌肉生物力学特性的影响

IF 1.4 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Sungyeon Oh, Chang-Yong Ko, Jaewon Lee, Daekook M Nekar, Hyeyoon Kang, Hansung Kim, Jaeho Yu
{"title":"可穿戴低强度连续超声波对迟发性肌肉酸痛期间肌肉生物力学特性的影响","authors":"Sungyeon Oh, Chang-Yong Ko, Jaewon Lee, Daekook M Nekar, Hyeyoon Kang, Hansung Kim, Jaeho Yu","doi":"10.3233/THC-231947","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Delayed onset muscle soreness (DOMS) is one of the most prevalent musculoskeletal symptoms in individuals engaged in strenuous exercise programs.</p><p><strong>Objective: </strong>This study investigated the effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during DOMS.</p><p><strong>Methods: </strong>Twenty volunteers were distributed into a wearable ultrasound stimulation group (WUG) (n= 10) and medical ultrasound stimulation group (MUG) (n= 10). All subjects performed wrist extensor muscle strength exercises to induce DOMS. At the site of pain, ultrasound of frequency 3 MHz was applied for 1 h or 5 min in each subject of the WUG or MUG, respectively. Before and after ultrasound stimulation, muscle biomechanical properties (tone, stiffness, elasticity, stress relaxation time, and creep) and body temperature were measured, and pain was evaluated.</p><p><strong>Results: </strong>A significant decrease was found in the tone, stiffness, stress relaxation time, and creep in both groups after ultrasound stimulation (all p< 0.05). A significant decrease in the pain and increases in temperature were observed in both groups (all p< 0.05). No significant differences were observed between the groups in most evaluations.</p><p><strong>Conclusion: </strong>The stiffness and pain caused by DOMS were alleviated using a wearable ultrasound stimulator. Furthermore, the effects of the wearable ultrasound stimulator were like those of a medical ultrasound stimulator.</p>","PeriodicalId":48978,"journal":{"name":"Technology and Health Care","volume":" ","pages":"3253-3262"},"PeriodicalIF":1.4000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11492087/pdf/","citationCount":"0","resultStr":"{\"title\":\"Effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during delayed onset muscle soreness.\",\"authors\":\"Sungyeon Oh, Chang-Yong Ko, Jaewon Lee, Daekook M Nekar, Hyeyoon Kang, Hansung Kim, Jaeho Yu\",\"doi\":\"10.3233/THC-231947\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Delayed onset muscle soreness (DOMS) is one of the most prevalent musculoskeletal symptoms in individuals engaged in strenuous exercise programs.</p><p><strong>Objective: </strong>This study investigated the effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during DOMS.</p><p><strong>Methods: </strong>Twenty volunteers were distributed into a wearable ultrasound stimulation group (WUG) (n= 10) and medical ultrasound stimulation group (MUG) (n= 10). All subjects performed wrist extensor muscle strength exercises to induce DOMS. At the site of pain, ultrasound of frequency 3 MHz was applied for 1 h or 5 min in each subject of the WUG or MUG, respectively. Before and after ultrasound stimulation, muscle biomechanical properties (tone, stiffness, elasticity, stress relaxation time, and creep) and body temperature were measured, and pain was evaluated.</p><p><strong>Results: </strong>A significant decrease was found in the tone, stiffness, stress relaxation time, and creep in both groups after ultrasound stimulation (all p< 0.05). A significant decrease in the pain and increases in temperature were observed in both groups (all p< 0.05). No significant differences were observed between the groups in most evaluations.</p><p><strong>Conclusion: </strong>The stiffness and pain caused by DOMS were alleviated using a wearable ultrasound stimulator. Furthermore, the effects of the wearable ultrasound stimulator were like those of a medical ultrasound stimulator.</p>\",\"PeriodicalId\":48978,\"journal\":{\"name\":\"Technology and Health Care\",\"volume\":\" \",\"pages\":\"3253-3262\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11492087/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Technology and Health Care\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3233/THC-231947\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Technology and Health Care","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3233/THC-231947","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景:延迟性肌肉酸痛(DOMS延迟性肌肉酸痛(DOMS)是剧烈运动者最常见的肌肉骨骼症状之一:本研究调查了可穿戴低强度连续超声波对 DOMS 期间肌肉生物力学特性的影响:20名志愿者被分为可穿戴超声波刺激组(WUG)(10人)和医用超声波刺激组(MUG)(10人)。所有受试者都进行了腕部伸肌力量练习,以诱发 DOMS。在疼痛部位,WUG 组和 MUG 组的每位受试者分别接受频率为 3 MHz 的超声波刺激 1 小时或 5 分钟。在超声波刺激前后,测量了肌肉的生物力学特性(张力、硬度、弹性、应力松弛时间和蠕变)和体温,并对疼痛进行了评估:结果:超声波刺激后,两组肌肉的张力、僵硬度、应力松弛时间和蠕动均明显下降(均为 p<0.05)。两组患者的疼痛明显减轻,体温明显升高(均为 P< 0.05)。在大多数评估中,两组之间未发现明显差异:结论:使用可穿戴超声波刺激器可以缓解 DOMS 引起的僵硬和疼痛。此外,可穿戴超声波刺激器的效果与医用超声波刺激器相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during delayed onset muscle soreness.

Background: Delayed onset muscle soreness (DOMS) is one of the most prevalent musculoskeletal symptoms in individuals engaged in strenuous exercise programs.

Objective: This study investigated the effects of wearable low-intensity continuous ultrasound on muscle biomechanical properties during DOMS.

Methods: Twenty volunteers were distributed into a wearable ultrasound stimulation group (WUG) (n= 10) and medical ultrasound stimulation group (MUG) (n= 10). All subjects performed wrist extensor muscle strength exercises to induce DOMS. At the site of pain, ultrasound of frequency 3 MHz was applied for 1 h or 5 min in each subject of the WUG or MUG, respectively. Before and after ultrasound stimulation, muscle biomechanical properties (tone, stiffness, elasticity, stress relaxation time, and creep) and body temperature were measured, and pain was evaluated.

Results: A significant decrease was found in the tone, stiffness, stress relaxation time, and creep in both groups after ultrasound stimulation (all p< 0.05). A significant decrease in the pain and increases in temperature were observed in both groups (all p< 0.05). No significant differences were observed between the groups in most evaluations.

Conclusion: The stiffness and pain caused by DOMS were alleviated using a wearable ultrasound stimulator. Furthermore, the effects of the wearable ultrasound stimulator were like those of a medical ultrasound stimulator.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Technology and Health Care
Technology and Health Care HEALTH CARE SCIENCES & SERVICES-ENGINEERING, BIOMEDICAL
CiteScore
2.10
自引率
6.20%
发文量
282
审稿时长
>12 weeks
期刊介绍: Technology and Health Care is intended to serve as a forum for the presentation of original articles and technical notes, observing rigorous scientific standards. Furthermore, upon invitation, reviews, tutorials, discussion papers and minisymposia are featured. The main focus of THC is related to the overlapping areas of engineering and medicine. The following types of contributions are considered: 1.Original articles: New concepts, procedures and devices associated with the use of technology in medical research and clinical practice are presented to a readership with a widespread background in engineering and/or medicine. In particular, the clinical benefit deriving from the application of engineering methods and devices in clinical medicine should be demonstrated. Typically, full length original contributions have a length of 4000 words, thereby taking duly into account figures and tables. 2.Technical Notes and Short Communications: Technical Notes relate to novel technical developments with relevance for clinical medicine. In Short Communications, clinical applications are shortly described. 3.Both Technical Notes and Short Communications typically have a length of 1500 words. Reviews and Tutorials (upon invitation only): Tutorial and educational articles for persons with a primarily medical background on principles of engineering with particular significance for biomedical applications and vice versa are presented. The Editorial Board is responsible for the selection of topics. 4.Minisymposia (upon invitation only): Under the leadership of a Special Editor, controversial or important issues relating to health care are highlighted and discussed by various authors. 5.Letters to the Editors: Discussions or short statements (not indexed).
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信