{"title":"利用柱吸附/萃取和亲水液相色谱-电喷雾串联质谱法测量大气中的胺和氨基酰胺。","authors":"Kentaro Saeki,&nbsp;Kazuya Ikari,&nbsp;Shin-Ichi Ohira,&nbsp;Kei Toda","doi":"10.1007/s44211-024-00626-3","DOIUrl":null,"url":null,"abstract":"<div><p>Sampling and chromatography-mass spectrometry methods were investigated to measure atmospheric amines and aminoamides. Amines and their amide derivatives play significant roles in new particle formation (NPF) in the atmosphere, especially diamines and aminoamides have higher NPF potentials compared to monoamines. For amine sampling, silica gel tube collection and formic acid extraction gave good overall recoveries (&gt;93 ± 8%) for mono-, di-, tri-, tetramines, and aminoamides. Two chromatography methods were subjected to analyze the extracted amines. One involved direct analysis using hydrophilic interaction liquid chromatography with carboxyl or diol group functioned separation column (carboxyl-HILIC or diol-HILIC), and the other utilized derivatization with 4-(<i>N</i>,<i>N</i>-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) and subsequent reversed-phase chromatography (HPLC). Separated amines were detected by electrospray ionization and tandem mass spectrometry in both cases. DBD-F-HPLC method provided good sensitivity for mono- and all polyamines (limit of detection (LOD) &lt; 4.6 nM, relative standard deviation (RSD) for 100 nM &lt; 9.2%). However, aminoamides could not be detected by DBD-F-HPLC. Carboxyl-HILIC provided good sensitivities for mono- and diamines and aminoamides (LOD &lt; 1.6 nM, RSD &lt; 4.8%). Forest air measurement was performed and data obtained by carboxyl-HILIC and DBD-F-HPLC showed good agreement for 1,3-diaminopropane, 1,4-diaminobutane (putrescine) and 1,5-diaminopentane (cadaverine) (<i>R</i><sup>2</sup> = 0.9215–0.9739, <i>n</i> = 7–14). Carboxyl-HILIC method was the best for the amine analysis, and combination with silica gel tube sampling provides atmospheric monitoring available. The developed method can be used not only to study atmospheric chemistry of diamines and aminoamides but also to analyze flavor/odor of foods, flowers and wastes.</p><h3>Graphical Abstract</h3>\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>","PeriodicalId":7802,"journal":{"name":"Analytical Sciences","volume":"40 10","pages":"1907 - 1918"},"PeriodicalIF":1.8000,"publicationDate":"2024-07-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Measurement of atmospheric amines and aminoamides by column adsorption/extraction and hydrophilic liquid chromatography-electrospray-tandem mass spectrometry\",\"authors\":\"Kentaro Saeki,&nbsp;Kazuya Ikari,&nbsp;Shin-Ichi Ohira,&nbsp;Kei Toda\",\"doi\":\"10.1007/s44211-024-00626-3\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Sampling and chromatography-mass spectrometry methods were investigated to measure atmospheric amines and aminoamides. Amines and their amide derivatives play significant roles in new particle formation (NPF) in the atmosphere, especially diamines and aminoamides have higher NPF potentials compared to monoamines. For amine sampling, silica gel tube collection and formic acid extraction gave good overall recoveries (&gt;93 ± 8%) for mono-, di-, tri-, tetramines, and aminoamides. Two chromatography methods were subjected to analyze the extracted amines. One involved direct analysis using hydrophilic interaction liquid chromatography with carboxyl or diol group functioned separation column (carboxyl-HILIC or diol-HILIC), and the other utilized derivatization with 4-(<i>N</i>,<i>N</i>-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) and subsequent reversed-phase chromatography (HPLC). Separated amines were detected by electrospray ionization and tandem mass spectrometry in both cases. DBD-F-HPLC method provided good sensitivity for mono- and all polyamines (limit of detection (LOD) &lt; 4.6 nM, relative standard deviation (RSD) for 100 nM &lt; 9.2%). However, aminoamides could not be detected by DBD-F-HPLC. Carboxyl-HILIC provided good sensitivities for mono- and diamines and aminoamides (LOD &lt; 1.6 nM, RSD &lt; 4.8%). Forest air measurement was performed and data obtained by carboxyl-HILIC and DBD-F-HPLC showed good agreement for 1,3-diaminopropane, 1,4-diaminobutane (putrescine) and 1,5-diaminopentane (cadaverine) (<i>R</i><sup>2</sup> = 0.9215–0.9739, <i>n</i> = 7–14). Carboxyl-HILIC method was the best for the amine analysis, and combination with silica gel tube sampling provides atmospheric monitoring available. The developed method can be used not only to study atmospheric chemistry of diamines and aminoamides but also to analyze flavor/odor of foods, flowers and wastes.</p><h3>Graphical Abstract</h3>\\n<div><figure><div><div><picture><source><img></source></picture></div></div></figure></div></div>\",\"PeriodicalId\":7802,\"journal\":{\"name\":\"Analytical Sciences\",\"volume\":\"40 10\",\"pages\":\"1907 - 1918\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2024-07-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical Sciences\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s44211-024-00626-3\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Sciences","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s44211-024-00626-3","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

摘要

研究了测量大气胺和氨基酰胺的采样和色谱-质谱方法。胺及其酰胺衍生物在大气中新粒子形成(NPF)过程中发挥着重要作用,尤其是二胺和酰胺与单胺相比具有更高的 NPF 潜能。在胺采样方面,硅胶管收集和甲酸萃取法对单胺、二胺、三胺、四胺和氨基酰胺的总体回收率较高(>93 ± 8%)。采用两种色谱法对提取的胺进行分析。一种是利用亲水作用液相色谱法与羧基或二元醇基分离柱(羧基-HILIC 或二元醇-HILIC)直接分析,另一种是利用 4-(N,N-二甲基氨基磺酰基)-7-氟-2,1,3-苯并噁二唑(DBD-F)衍生化,然后进行反相色谱法(HPLC)。分离出的胺均通过电喷雾离子化和串联质谱法进行检测。DBD-F-HPLC 法对单胺和所有多胺具有良好的灵敏度(检测限 (LOD) 2 = 0.9215-0.9739, n = 7-14)。羧基-HILIC 方法是胺分析的最佳方法,与硅胶管取样相结合,可用于大气监测。所开发的方法不仅可用于研究二胺和氨基酰胺的大气化学性质,还可用于分析食品、花卉和废物的味道/气味。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Measurement of atmospheric amines and aminoamides by column adsorption/extraction and hydrophilic liquid chromatography-electrospray-tandem mass spectrometry

Sampling and chromatography-mass spectrometry methods were investigated to measure atmospheric amines and aminoamides. Amines and their amide derivatives play significant roles in new particle formation (NPF) in the atmosphere, especially diamines and aminoamides have higher NPF potentials compared to monoamines. For amine sampling, silica gel tube collection and formic acid extraction gave good overall recoveries (>93 ± 8%) for mono-, di-, tri-, tetramines, and aminoamides. Two chromatography methods were subjected to analyze the extracted amines. One involved direct analysis using hydrophilic interaction liquid chromatography with carboxyl or diol group functioned separation column (carboxyl-HILIC or diol-HILIC), and the other utilized derivatization with 4-(N,N-dimethylaminosulfonyl)-7-fluoro-2,1,3-benzoxadiazole (DBD-F) and subsequent reversed-phase chromatography (HPLC). Separated amines were detected by electrospray ionization and tandem mass spectrometry in both cases. DBD-F-HPLC method provided good sensitivity for mono- and all polyamines (limit of detection (LOD) < 4.6 nM, relative standard deviation (RSD) for 100 nM < 9.2%). However, aminoamides could not be detected by DBD-F-HPLC. Carboxyl-HILIC provided good sensitivities for mono- and diamines and aminoamides (LOD < 1.6 nM, RSD < 4.8%). Forest air measurement was performed and data obtained by carboxyl-HILIC and DBD-F-HPLC showed good agreement for 1,3-diaminopropane, 1,4-diaminobutane (putrescine) and 1,5-diaminopentane (cadaverine) (R2 = 0.9215–0.9739, n = 7–14). Carboxyl-HILIC method was the best for the amine analysis, and combination with silica gel tube sampling provides atmospheric monitoring available. The developed method can be used not only to study atmospheric chemistry of diamines and aminoamides but also to analyze flavor/odor of foods, flowers and wastes.

Graphical Abstract

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Analytical Sciences
Analytical Sciences 化学-分析化学
CiteScore
2.90
自引率
18.80%
发文量
232
审稿时长
1 months
期刊介绍: Analytical Sciences is an international journal published monthly by The Japan Society for Analytical Chemistry. The journal publishes papers on all aspects of the theory and practice of analytical sciences, including fundamental and applied, inorganic and organic, wet chemical and instrumental methods. This publication is supported in part by the Grant-in-Aid for Publication of Scientific Research Result of the Japanese Ministry of Education, Culture, Sports, Science and Technology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信