在确认压力性尿失禁时,尿动力评估与邦尼测试的可靠性。

IF 0.7 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Željko Blažinkov, Ines Krištofić, Ivan Jandrić, Mihaela Blažinkov, Boris Lovrić, Dragica Pavlović, Maja Čebohin, Slavko Marinić
{"title":"在确认压力性尿失禁时,尿动力评估与邦尼测试的可靠性。","authors":"Željko Blažinkov, Ines Krištofić, Ivan Jandrić, Mihaela Blažinkov, Boris Lovrić, Dragica Pavlović, Maja Čebohin, Slavko Marinić","doi":"10.20471/acc.2023.62.s2.1","DOIUrl":null,"url":null,"abstract":"<p><p>According to the International Continence Society, stress (static) urinary incontinence is defined as any involuntary loss of urine on effort or physical exertion, due to which intravesical pressure overcomes urethral pressure, with no detrusor activity. Urodynamic testing accurately assesses the function of the bladder and urethra. The urodynamic assessment includes three tests: cystometry, uroflowmetry and profilometry (determination of urethral pressure profile). Prior to urodynamic assessment, it is mandatory to rule out urinary tract infection since it is an invasive test. Urethral profilometry is a technique that measures pressure in the urethra and bladder at rest, during stressful actions, and during the act of miction. Its main purpose is to evaluate the sphincter mechanism. During the examination, a special catheter is used, which is being slowly pulled out from the bladder neck throughout the urethra, with continuous recording of intraurethral pressure. In addition to measuring urethral pressures, stress urinary incontinence is also very successfully proven by the cough test and Bonney test. If, on forced cough, the urine escapes uncontrollably, and continence is restored by finger lifting the neck of the bladder, the diagnosis of static incontinence is confirmed. At our urogynecologic clinic, urodynamic examination is being routinely performed. In the present study, we included patients previously treated for urinary stress incontinence and compared their results of urodynamic assessment to the results of Bonney test. Of the 43 subjects in whom stress incontinence was proven with Bonney test, we recorded an appropriate profilometry result in 13 cases.</p>","PeriodicalId":7072,"journal":{"name":"Acta clinica Croatica","volume":"62 Suppl2","pages":"9-13"},"PeriodicalIF":0.7000,"publicationDate":"2023-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11221237/pdf/","citationCount":"0","resultStr":"{\"title\":\"THE RELIABILITY OF URODYNAMIC ASSESSMENT IN CONFIRMATION OF STRESS URINARY INCONTINENCE IN RELATION TO BONNEY TEST.\",\"authors\":\"Željko Blažinkov, Ines Krištofić, Ivan Jandrić, Mihaela Blažinkov, Boris Lovrić, Dragica Pavlović, Maja Čebohin, Slavko Marinić\",\"doi\":\"10.20471/acc.2023.62.s2.1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>According to the International Continence Society, stress (static) urinary incontinence is defined as any involuntary loss of urine on effort or physical exertion, due to which intravesical pressure overcomes urethral pressure, with no detrusor activity. Urodynamic testing accurately assesses the function of the bladder and urethra. The urodynamic assessment includes three tests: cystometry, uroflowmetry and profilometry (determination of urethral pressure profile). Prior to urodynamic assessment, it is mandatory to rule out urinary tract infection since it is an invasive test. Urethral profilometry is a technique that measures pressure in the urethra and bladder at rest, during stressful actions, and during the act of miction. Its main purpose is to evaluate the sphincter mechanism. During the examination, a special catheter is used, which is being slowly pulled out from the bladder neck throughout the urethra, with continuous recording of intraurethral pressure. In addition to measuring urethral pressures, stress urinary incontinence is also very successfully proven by the cough test and Bonney test. If, on forced cough, the urine escapes uncontrollably, and continence is restored by finger lifting the neck of the bladder, the diagnosis of static incontinence is confirmed. At our urogynecologic clinic, urodynamic examination is being routinely performed. In the present study, we included patients previously treated for urinary stress incontinence and compared their results of urodynamic assessment to the results of Bonney test. Of the 43 subjects in whom stress incontinence was proven with Bonney test, we recorded an appropriate profilometry result in 13 cases.</p>\",\"PeriodicalId\":7072,\"journal\":{\"name\":\"Acta clinica Croatica\",\"volume\":\"62 Suppl2\",\"pages\":\"9-13\"},\"PeriodicalIF\":0.7000,\"publicationDate\":\"2023-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11221237/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta clinica Croatica\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.20471/acc.2023.62.s2.1\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta clinica Croatica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.20471/acc.2023.62.s2.1","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

摘要

根据国际尿失禁协会(International Continence Society)的定义,压力性(静态)尿失禁是指膀胱内压超过尿道内压,在无逼尿肌活动的情况下,在用力或体力消耗时出现的任何不自主尿失禁。尿动力学检查可准确评估膀胱和尿道的功能。尿动力学评估包括三项测试:膀胱测量、尿流率测量和尿道压力曲线测量。在进行尿动力学评估之前,必须先排除尿路感染,因为这是一项侵入性检查。尿道压力剖面测量法是一种测量静息状态、紧张动作和排便时尿道和膀胱压力的技术。其主要目的是评估括约肌机制。在检查过程中,医生会使用一根特殊的导尿管,从膀胱颈部缓慢拉出导尿管至整个尿道,并持续记录尿道内的压力。除了测量尿道压力外,压力性尿失禁还可以通过咳嗽试验和邦尼试验来证明。如果用力咳嗽时,尿液不受控制地流出,用手指抬起膀胱颈即可恢复排尿,则可确诊为静态尿失禁。在我们的泌尿妇科诊所,尿动力检查是常规检查项目。在本研究中,我们纳入了曾接受过压力性尿失禁治疗的患者,并将他们的尿动力学评估结果与邦尼测试结果进行了比较。在 43 例经 Bonney 试验证实为压力性尿失禁的受试者中,我们记录了 13 例适当的轮廓测量结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
THE RELIABILITY OF URODYNAMIC ASSESSMENT IN CONFIRMATION OF STRESS URINARY INCONTINENCE IN RELATION TO BONNEY TEST.

According to the International Continence Society, stress (static) urinary incontinence is defined as any involuntary loss of urine on effort or physical exertion, due to which intravesical pressure overcomes urethral pressure, with no detrusor activity. Urodynamic testing accurately assesses the function of the bladder and urethra. The urodynamic assessment includes three tests: cystometry, uroflowmetry and profilometry (determination of urethral pressure profile). Prior to urodynamic assessment, it is mandatory to rule out urinary tract infection since it is an invasive test. Urethral profilometry is a technique that measures pressure in the urethra and bladder at rest, during stressful actions, and during the act of miction. Its main purpose is to evaluate the sphincter mechanism. During the examination, a special catheter is used, which is being slowly pulled out from the bladder neck throughout the urethra, with continuous recording of intraurethral pressure. In addition to measuring urethral pressures, stress urinary incontinence is also very successfully proven by the cough test and Bonney test. If, on forced cough, the urine escapes uncontrollably, and continence is restored by finger lifting the neck of the bladder, the diagnosis of static incontinence is confirmed. At our urogynecologic clinic, urodynamic examination is being routinely performed. In the present study, we included patients previously treated for urinary stress incontinence and compared their results of urodynamic assessment to the results of Bonney test. Of the 43 subjects in whom stress incontinence was proven with Bonney test, we recorded an appropriate profilometry result in 13 cases.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Acta clinica Croatica
Acta clinica Croatica 医学-医学:内科
CiteScore
1.10
自引率
16.70%
发文量
38
审稿时长
6-12 weeks
期刊介绍: Acta Clinica Croatica is a peer reviewed general medical journal that publishes original articles that advance and improve medical science and practice and that serve the purpose of transfer of original and valuable information to journal readers. Acta Clinica Croatica is published in English four times a year.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信