A. Milenin, P. Kustra, U. Lelek-Borkowska, M. Wróbel, M. Marzec, J. Sulej-Chojnacka, J. Półrolniczak, I. Polkowska, B. Nowicka
{"title":"用锌基低合金通过热拔和冷拔生产的新型可溶解手术线材的体外和体内降解情况","authors":"A. Milenin, P. Kustra, U. Lelek-Borkowska, M. Wróbel, M. Marzec, J. Sulej-Chojnacka, J. Półrolniczak, I. Polkowska, B. Nowicka","doi":"10.1007/s11661-024-07470-0","DOIUrl":null,"url":null,"abstract":"<p>The biocorrosion of a new surgical wire (0.6, 0.8, and 1.0 mm in diameter) obtained from a ZnMg0.004 alloy by hot and cold drawing was characterized using <i>in vitro</i> tests in a bovine animal serum solution and <i>in vivo</i> tests – through placement in the muscles of a rabbit and a in cat's broken paw. Corrosion gravimetric tests were carried out in a corrosive environment refreshed every 3 days and also one which remained unchanged throughout the test period. Electrochemical tests were performed in the same solution of serum as in gravimetric tests. Depending on the initial diameter, complete dissolution of the wire was observed after 36-78 days of immersion in periodically changed serum solution. None of the wires completely dissolved over 120 days in the unreplaced serum solution. The corrosion rate values determined in electrochemical and gravimetric tests were similar. After 90 days of <i>in vivo</i> tests, both in the body of the rabbit and the cat, the degradation of the wire was similar to <i>in vitro</i> tests in the unreplaced serum solution. No harmful effects were observed in the animals.</p>","PeriodicalId":18504,"journal":{"name":"Metallurgical and Materials Transactions A","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vitro and In Vivo Degradation of the New Dissolvable Surgical Wire, Produced from Zn Based Low Alloy by Hot and Cold Drawing\",\"authors\":\"A. Milenin, P. Kustra, U. Lelek-Borkowska, M. Wróbel, M. Marzec, J. Sulej-Chojnacka, J. Półrolniczak, I. Polkowska, B. Nowicka\",\"doi\":\"10.1007/s11661-024-07470-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The biocorrosion of a new surgical wire (0.6, 0.8, and 1.0 mm in diameter) obtained from a ZnMg0.004 alloy by hot and cold drawing was characterized using <i>in vitro</i> tests in a bovine animal serum solution and <i>in vivo</i> tests – through placement in the muscles of a rabbit and a in cat's broken paw. Corrosion gravimetric tests were carried out in a corrosive environment refreshed every 3 days and also one which remained unchanged throughout the test period. Electrochemical tests were performed in the same solution of serum as in gravimetric tests. Depending on the initial diameter, complete dissolution of the wire was observed after 36-78 days of immersion in periodically changed serum solution. None of the wires completely dissolved over 120 days in the unreplaced serum solution. The corrosion rate values determined in electrochemical and gravimetric tests were similar. After 90 days of <i>in vivo</i> tests, both in the body of the rabbit and the cat, the degradation of the wire was similar to <i>in vitro</i> tests in the unreplaced serum solution. No harmful effects were observed in the animals.</p>\",\"PeriodicalId\":18504,\"journal\":{\"name\":\"Metallurgical and Materials Transactions A\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metallurgical and Materials Transactions A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s11661-024-07470-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metallurgical and Materials Transactions A","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11661-024-07470-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
In Vitro and In Vivo Degradation of the New Dissolvable Surgical Wire, Produced from Zn Based Low Alloy by Hot and Cold Drawing
The biocorrosion of a new surgical wire (0.6, 0.8, and 1.0 mm in diameter) obtained from a ZnMg0.004 alloy by hot and cold drawing was characterized using in vitro tests in a bovine animal serum solution and in vivo tests – through placement in the muscles of a rabbit and a in cat's broken paw. Corrosion gravimetric tests were carried out in a corrosive environment refreshed every 3 days and also one which remained unchanged throughout the test period. Electrochemical tests were performed in the same solution of serum as in gravimetric tests. Depending on the initial diameter, complete dissolution of the wire was observed after 36-78 days of immersion in periodically changed serum solution. None of the wires completely dissolved over 120 days in the unreplaced serum solution. The corrosion rate values determined in electrochemical and gravimetric tests were similar. After 90 days of in vivo tests, both in the body of the rabbit and the cat, the degradation of the wire was similar to in vitro tests in the unreplaced serum solution. No harmful effects were observed in the animals.