用锌基低合金通过热拔和冷拔生产的新型可溶解手术线材的体外和体内降解情况

A. Milenin, P. Kustra, U. Lelek-Borkowska, M. Wróbel, M. Marzec, J. Sulej-Chojnacka, J. Półrolniczak, I. Polkowska, B. Nowicka
{"title":"用锌基低合金通过热拔和冷拔生产的新型可溶解手术线材的体外和体内降解情况","authors":"A. Milenin, P. Kustra, U. Lelek-Borkowska, M. Wróbel, M. Marzec, J. Sulej-Chojnacka, J. Półrolniczak, I. Polkowska, B. Nowicka","doi":"10.1007/s11661-024-07470-0","DOIUrl":null,"url":null,"abstract":"<p>The biocorrosion of a new surgical wire (0.6, 0.8, and 1.0 mm in diameter) obtained from a ZnMg0.004 alloy by hot and cold drawing was characterized using <i>in vitro</i> tests in a bovine animal serum solution and <i>in vivo</i> tests – through placement in the muscles of a rabbit and a in cat's broken paw. Corrosion gravimetric tests were carried out in a corrosive environment refreshed every 3 days and also one which remained unchanged throughout the test period. Electrochemical tests were performed in the same solution of serum as in gravimetric tests. Depending on the initial diameter, complete dissolution of the wire was observed after 36-78 days of immersion in periodically changed serum solution. None of the wires completely dissolved over 120 days in the unreplaced serum solution. The corrosion rate values determined in electrochemical and gravimetric tests were similar. After 90 days of <i>in vivo</i> tests, both in the body of the rabbit and the cat, the degradation of the wire was similar to <i>in vitro</i> tests in the unreplaced serum solution. No harmful effects were observed in the animals.</p>","PeriodicalId":18504,"journal":{"name":"Metallurgical and Materials Transactions A","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"In Vitro and In Vivo Degradation of the New Dissolvable Surgical Wire, Produced from Zn Based Low Alloy by Hot and Cold Drawing\",\"authors\":\"A. Milenin, P. Kustra, U. Lelek-Borkowska, M. Wróbel, M. Marzec, J. Sulej-Chojnacka, J. Półrolniczak, I. Polkowska, B. Nowicka\",\"doi\":\"10.1007/s11661-024-07470-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The biocorrosion of a new surgical wire (0.6, 0.8, and 1.0 mm in diameter) obtained from a ZnMg0.004 alloy by hot and cold drawing was characterized using <i>in vitro</i> tests in a bovine animal serum solution and <i>in vivo</i> tests – through placement in the muscles of a rabbit and a in cat's broken paw. Corrosion gravimetric tests were carried out in a corrosive environment refreshed every 3 days and also one which remained unchanged throughout the test period. Electrochemical tests were performed in the same solution of serum as in gravimetric tests. Depending on the initial diameter, complete dissolution of the wire was observed after 36-78 days of immersion in periodically changed serum solution. None of the wires completely dissolved over 120 days in the unreplaced serum solution. The corrosion rate values determined in electrochemical and gravimetric tests were similar. After 90 days of <i>in vivo</i> tests, both in the body of the rabbit and the cat, the degradation of the wire was similar to <i>in vitro</i> tests in the unreplaced serum solution. No harmful effects were observed in the animals.</p>\",\"PeriodicalId\":18504,\"journal\":{\"name\":\"Metallurgical and Materials Transactions A\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metallurgical and Materials Transactions A\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/s11661-024-07470-0\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metallurgical and Materials Transactions A","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/s11661-024-07470-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

通过在牛血清溶液中进行体外试验和体内试验--将其放置在兔子和猫的断爪肌肉中,对由 ZnMg0.004 合金通过冷热拉拔制成的新型手术线(直径分别为 0.6、0.8 和 1.0 毫米)的生物腐蚀性进行了鉴定。腐蚀重力测试是在每 3 天刷新一次的腐蚀性环境和整个测试期间保持不变的环境中进行的。电化学测试在与重量测试相同的血清溶液中进行。根据初始直径的不同,在定期更换的血清溶液中浸泡 36-78 天后,可观察到金属丝完全溶解。在未更换的血清溶液中浸泡 120 天后,没有一根金属丝完全溶解。电化学测试和重量测试中测定的腐蚀速率值相似。在兔子和猫体内进行 90 天的体内试验后,金属丝的降解情况与在未更换的血清溶液中进行的体外试验相似。在动物体内没有观察到有害影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

In Vitro and In Vivo Degradation of the New Dissolvable Surgical Wire, Produced from Zn Based Low Alloy by Hot and Cold Drawing

In Vitro and In Vivo Degradation of the New Dissolvable Surgical Wire, Produced from Zn Based Low Alloy by Hot and Cold Drawing

The biocorrosion of a new surgical wire (0.6, 0.8, and 1.0 mm in diameter) obtained from a ZnMg0.004 alloy by hot and cold drawing was characterized using in vitro tests in a bovine animal serum solution and in vivo tests – through placement in the muscles of a rabbit and a in cat's broken paw. Corrosion gravimetric tests were carried out in a corrosive environment refreshed every 3 days and also one which remained unchanged throughout the test period. Electrochemical tests were performed in the same solution of serum as in gravimetric tests. Depending on the initial diameter, complete dissolution of the wire was observed after 36-78 days of immersion in periodically changed serum solution. None of the wires completely dissolved over 120 days in the unreplaced serum solution. The corrosion rate values determined in electrochemical and gravimetric tests were similar. After 90 days of in vivo tests, both in the body of the rabbit and the cat, the degradation of the wire was similar to in vitro tests in the unreplaced serum solution. No harmful effects were observed in the animals.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信