{"title":"酸浓度对联合清洗燃气轮机喷嘴叶片金属氧化物的影响","authors":"D. D. Fomina, V. Z. Poilov","doi":"10.1007/s11041-024-01026-0","DOIUrl":null,"url":null,"abstract":"<p>The method of chemical cleaning of the surface of blades of gas turbine units in a solution of orthophosphoric and sulfuric acids using a purpose-designed closed-type autoclave microwave system “Mars 5” and ultrasonic exposure in distilled water is described. The two-stage cleaning involves the chemical action of the acid solution in the autoclave and ultrasonic cleaning in the stage of washing. The effect of acid solutions of various concentrations on the degree of surface cleaning from metal oxides and microcracks in the gas turbine blades is studied. It is shown that when the samples of gas turbine blades are treated in the “Mars 5” autoclave with a solution of acids and with ultrasound in the washing stage, the residual oxygen content reflecting the presence of oxides on the surface of the samples is less than 1%.</p>","PeriodicalId":701,"journal":{"name":"Metal Science and Heat Treatment","volume":"66 1-2","pages":"111 - 114"},"PeriodicalIF":0.6000,"publicationDate":"2024-07-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Influence of Acid Concentration in Combined Cleaning of Gas Turbine Nozzle Blades from Metal Oxides\",\"authors\":\"D. D. Fomina, V. Z. Poilov\",\"doi\":\"10.1007/s11041-024-01026-0\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The method of chemical cleaning of the surface of blades of gas turbine units in a solution of orthophosphoric and sulfuric acids using a purpose-designed closed-type autoclave microwave system “Mars 5” and ultrasonic exposure in distilled water is described. The two-stage cleaning involves the chemical action of the acid solution in the autoclave and ultrasonic cleaning in the stage of washing. The effect of acid solutions of various concentrations on the degree of surface cleaning from metal oxides and microcracks in the gas turbine blades is studied. It is shown that when the samples of gas turbine blades are treated in the “Mars 5” autoclave with a solution of acids and with ultrasound in the washing stage, the residual oxygen content reflecting the presence of oxides on the surface of the samples is less than 1%.</p>\",\"PeriodicalId\":701,\"journal\":{\"name\":\"Metal Science and Heat Treatment\",\"volume\":\"66 1-2\",\"pages\":\"111 - 114\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2024-07-02\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metal Science and Heat Treatment\",\"FirstCategoryId\":\"88\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s11041-024-01026-0\",\"RegionNum\":4,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"METALLURGY & METALLURGICAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metal Science and Heat Treatment","FirstCategoryId":"88","ListUrlMain":"https://link.springer.com/article/10.1007/s11041-024-01026-0","RegionNum":4,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
Influence of Acid Concentration in Combined Cleaning of Gas Turbine Nozzle Blades from Metal Oxides
The method of chemical cleaning of the surface of blades of gas turbine units in a solution of orthophosphoric and sulfuric acids using a purpose-designed closed-type autoclave microwave system “Mars 5” and ultrasonic exposure in distilled water is described. The two-stage cleaning involves the chemical action of the acid solution in the autoclave and ultrasonic cleaning in the stage of washing. The effect of acid solutions of various concentrations on the degree of surface cleaning from metal oxides and microcracks in the gas turbine blades is studied. It is shown that when the samples of gas turbine blades are treated in the “Mars 5” autoclave with a solution of acids and with ultrasound in the washing stage, the residual oxygen content reflecting the presence of oxides on the surface of the samples is less than 1%.
期刊介绍:
Metal Science and Heat Treatment presents new fundamental and practical research in physical metallurgy, heat treatment equipment, and surface engineering.
Topics covered include:
New structural, high temperature, tool and precision steels;
Cold-resistant, corrosion-resistant and radiation-resistant steels;
Steels with rapid decline of induced properties;
Alloys with shape memory effect;
Bulk-amorphyzable metal alloys;
Microcrystalline alloys;
Nano materials and foam materials for medical use.