CAD/CAM 车针寿命对牙科氧化锆表面特性的影响:对定制基台生物相容性的影响。

IF 3.2 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Liliane Cristina Nogueira Marinho DDS, MS, PhD, Raissa Pinheiro de Paiva DDS, MS, Ana Luísa de Barros Pascoal DDS, MS, PhD, Carlos Augusto Galvão Barboza DDS, MS, PhD, André Ulisses Dantas Batista DS, MS, PhD, Patrícia dos Santos Calderon DDS, MS, PhD
{"title":"CAD/CAM 车针寿命对牙科氧化锆表面特性的影响:对定制基台生物相容性的影响。","authors":"Liliane Cristina Nogueira Marinho DDS, MS, PhD,&nbsp;Raissa Pinheiro de Paiva DDS, MS,&nbsp;Ana Luísa de Barros Pascoal DDS, MS, PhD,&nbsp;Carlos Augusto Galvão Barboza DDS, MS, PhD,&nbsp;André Ulisses Dantas Batista DS, MS, PhD,&nbsp;Patrícia dos Santos Calderon DDS, MS, PhD","doi":"10.1111/jerd.13277","DOIUrl":null,"url":null,"abstract":"<div>\n \n \n <section>\n \n <h3> Objective</h3>\n \n <p>To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability.</p>\n </section>\n \n <section>\n \n <h3> Materials and Methods</h3>\n \n <p>Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (<i>n</i> = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal–Wallis tests (<i>p</i> ≤ 0.05).</p>\n </section>\n \n <section>\n \n <h3> Results</h3>\n \n <p>Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (<i>p</i> &lt; 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (<i>p</i> &lt; 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (<i>p</i> &gt; 0.05).</p>\n </section>\n \n <section>\n \n <h3> Conclusions</h3>\n \n <p>The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation.</p>\n </section>\n \n <section>\n \n <h3> Clinical Significance</h3>\n \n <p>The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.</p>\n </section>\n </div>","PeriodicalId":15988,"journal":{"name":"Journal of Esthetic and Restorative Dentistry","volume":null,"pages":null},"PeriodicalIF":3.2000,"publicationDate":"2024-07-04","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Impact of CAD/CAM burs lifetime on surface properties of dental zirconia: Implications for biocompatibility of custom abutments\",\"authors\":\"Liliane Cristina Nogueira Marinho DDS, MS, PhD,&nbsp;Raissa Pinheiro de Paiva DDS, MS,&nbsp;Ana Luísa de Barros Pascoal DDS, MS, PhD,&nbsp;Carlos Augusto Galvão Barboza DDS, MS, PhD,&nbsp;André Ulisses Dantas Batista DS, MS, PhD,&nbsp;Patrícia dos Santos Calderon DDS, MS, PhD\",\"doi\":\"10.1111/jerd.13277\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div>\\n \\n \\n <section>\\n \\n <h3> Objective</h3>\\n \\n <p>To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Materials and Methods</h3>\\n \\n <p>Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (<i>n</i> = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal–Wallis tests (<i>p</i> ≤ 0.05).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Results</h3>\\n \\n <p>Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (<i>p</i> &lt; 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (<i>p</i> &lt; 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (<i>p</i> &gt; 0.05).</p>\\n </section>\\n \\n <section>\\n \\n <h3> Conclusions</h3>\\n \\n <p>The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation.</p>\\n </section>\\n \\n <section>\\n \\n <h3> Clinical Significance</h3>\\n \\n <p>The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.</p>\\n </section>\\n </div>\",\"PeriodicalId\":15988,\"journal\":{\"name\":\"Journal of Esthetic and Restorative Dentistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.2000,\"publicationDate\":\"2024-07-04\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Esthetic and Restorative Dentistry\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13277\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Esthetic and Restorative Dentistry","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/jerd.13277","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

摘要

目的:评估计算机辅助设计/计算机辅助制造(CAD/CAM)车针在氧化锆铣削过程中的劣化对表面粗糙度、接触角和成纤维细胞活力的影响:研磨陶瓷块并制作 75 个陶瓷盘(8 × 1.5 毫米),将其分为三组(n = 25):G1-全新的 2L 和 1L 车针,G2-使用寿命结束时的 2L 车针和全新的 1L 车针,G3-使用寿命结束时的两种车针。粗糙度(Ra、Rq 和 Rz)使用三维光学轮廓仪进行评估,接触角使用无柄液滴法进行评估,小鼠 NIH/3T3 成纤维细胞的存活率使用阿拉玛蓝检测法,时间间隔为 24、48 和 72 小时(ISO 10993-5)。数据分析采用单因素方差分析和 Kruskal-Wallis 检验(P ≤ 0.05):结果:粗糙度随着车针的老化而增加,G3(0.27 ± 0.04)的 Ra 值更高(p 0.05):结论:车针退化会增加表面粗糙度并降低润湿性,但不会影响细胞活力和增殖:临床意义:使用定制氧化锆基台是单冠修复的有效策略。临床意义:使用定制氧化锆基台是单冠修复的有效策略。我们的研究结果表明,使用 CAD/CAM 车针可以在建议的使用寿命内有效地铣削这些基台。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Impact of CAD/CAM burs lifetime on surface properties of dental zirconia: Implications for biocompatibility of custom abutments

Objective

To evaluate the effect of the deterioration of computer aided design/computer aided manufacturing (CAD/CAM) burs during zirconia milling, on surface roughness, contact angle, and fibroblast viability.

Materials and Methods

Ceramic blocks were milled and 75 ceramic disks (8 × 1.5 mm) made and allocated into three groups (n = 25): G1-brand new 2L and 1L burs, G2-2L bur at the end of lifetime and brand new 1L bur and G3-both burs at the end of their lifetimes. Roughness (Ra, Rq, and Rz) was evaluated using a 3D optical profilometer, the contact angle by the sessile drop method and the cell viability of the mouse NIH/3T3 fibroblast, using the Alamar Blue assay at intervals of 24, 48, and 72 h (ISO 10993-5). Data were analyzed by one-way ANOVA and Kruskal–Wallis tests (p ≤ 0.05).

Results

Roughness increased as the burs deteriorated and G3 (0.27 ± 0.04) presented a higher value for Ra (p < 0.001). The highest contact angle was observed in G3 (86.2 ± 2.66) when compared with G1 (63.7 ± 12.49) and G2 (75.3 ± 6.36) (p < 0.001). Alamar Blue indicated an increase in cell proliferation, with no significant differences among the groups at 24 and 72 h (p > 0.05).

Conclusions

The deterioration of the burs increased the surface roughness and decreased the wettability, but did not interfere in cell viability and proliferation.

Clinical Significance

The use of custom zirconia abutments represents an effective strategy for single crowns restorations. Our findings suggest that these abutments can be efficiently milled using CAD/CAM burs within their recommended lifetime.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Esthetic and Restorative Dentistry
Journal of Esthetic and Restorative Dentistry 医学-牙科与口腔外科
CiteScore
6.30
自引率
6.20%
发文量
124
审稿时长
>12 weeks
期刊介绍: The Journal of Esthetic and Restorative Dentistry (JERD) is the longest standing peer-reviewed journal devoted solely to advancing the knowledge and practice of esthetic dentistry. Its goal is to provide the very latest evidence-based information in the realm of contemporary interdisciplinary esthetic dentistry through high quality clinical papers, sound research reports and educational features. The range of topics covered in the journal includes: - Interdisciplinary esthetic concepts - Implants - Conservative adhesive restorations - Tooth Whitening - Prosthodontic materials and techniques - Dental materials - Orthodontic, periodontal and endodontic esthetics - Esthetics related research - Innovations in esthetics
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信