带超级电容器和 DC-DC 级的级联 H 桥逆变器的协调电容器电压平衡方法

Ye Zhang;Zixin Li;Fanqiang Gao;Cong Zhao;Yaohua Li
{"title":"带超级电容器和 DC-DC 级的级联 H 桥逆变器的协调电容器电压平衡方法","authors":"Ye Zhang;Zixin Li;Fanqiang Gao;Cong Zhao;Yaohua Li","doi":"10.30941/CESTEMS.2024.00019","DOIUrl":null,"url":null,"abstract":"Cascaded H-bridge inverter (CHBI) with supercapacitors (SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dc-dc stage in each submodule (SM), while a hybrid modulation strategy (HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCS. Finally, both simulation and experimental results verify the effectiveness of the presented method.","PeriodicalId":100229,"journal":{"name":"CES Transactions on Electrical Machines and Systems","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10545358","citationCount":"0","resultStr":"{\"title\":\"Coordinated Capacitor Voltage Balancing Method for Cascaded H-Bridge Inverter with Supercapacitor and DC-DC Stage\",\"authors\":\"Ye Zhang;Zixin Li;Fanqiang Gao;Cong Zhao;Yaohua Li\",\"doi\":\"10.30941/CESTEMS.2024.00019\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Cascaded H-bridge inverter (CHBI) with supercapacitors (SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dc-dc stage in each submodule (SM), while a hybrid modulation strategy (HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCS. Finally, both simulation and experimental results verify the effectiveness of the presented method.\",\"PeriodicalId\":100229,\"journal\":{\"name\":\"CES Transactions on Electrical Machines and Systems\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=10545358\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"CES Transactions on Electrical Machines and Systems\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://ieeexplore.ieee.org/document/10545358/\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"CES Transactions on Electrical Machines and Systems","FirstCategoryId":"1085","ListUrlMain":"https://ieeexplore.ieee.org/document/10545358/","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

带有超级电容器(SC)和直流-直流级的级联 H 桥逆变器(CHBI)在中高压储能应用中大有可为。本文研究了 CHBI 内电容器(包括直流链路电容器和 SC)的电压平衡问题。每个子模块(SM)中的直流-直流级实现了对直流链路电容器电压的平衡控制,而混合调制策略(HMS)则在 H 桥中实施,以在 SM 之间平衡 SC 电压。同时,分析了 HMS 下的直流链路电压波动。引入了一个虚拟电压变量来协调直流链电容器电压和 SC 电压之间的平衡。与只考虑 SC 电压的平衡方法相比,所提出的方法在不影响 SCS 电压平衡的情况下减少了直流链电压波动。最后,模拟和实验结果都验证了所提出方法的有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Coordinated Capacitor Voltage Balancing Method for Cascaded H-Bridge Inverter with Supercapacitor and DC-DC Stage
Cascaded H-bridge inverter (CHBI) with supercapacitors (SCs) and dc-dc stage shows significant promise for medium to high voltage energy storage applications. This paper investigates the voltage balance of capacitors within the CHBI, including both the dc-link capacitors and SCs. Balance control over the dc-link capacitor voltages is realized by the dc-dc stage in each submodule (SM), while a hybrid modulation strategy (HMS) is implemented in the H-bridge to balance the SC voltages among the SMs. Meanwhile, the dc-link voltage fluctuations are analyzed under the HMS. A virtual voltage variable is introduced to coordinate the balancing of dc-link capacitor voltages and SC voltages. Compared to the balancing method that solely considers the SC voltages, the presented method reduces the dc-link voltage fluctuations without affecting the voltage balance of SCS. Finally, both simulation and experimental results verify the effectiveness of the presented method.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信