探索膝关节伸肌和屈肌偏心准等长肌肉动作的生物力学和疲劳模式。

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
ACS Applied Bio Materials Pub Date : 2024-11-01 Epub Date: 2024-07-02 DOI:10.1007/s00421-024-05544-w
Urška Ličen, Dustin J Oranchuk, Žiga Kozinc
{"title":"探索膝关节伸肌和屈肌偏心准等长肌肉动作的生物力学和疲劳模式。","authors":"Urška Ličen, Dustin J Oranchuk, Žiga Kozinc","doi":"10.1007/s00421-024-05544-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>Eccentric quasi-isometric (EQI) resistance training is emerging as a promising option in sports medicine and rehabilitation. Despite prior research on EQI contractions in quadriceps and biceps brachii, their use in hamstring injury contexts is underexplored. Therefore, our study examines and contrasts the biomechanics and fatigue effects of EQI training on knee extensors and flexors.</p><p><strong>Methods: </strong>Following familiarization, 16 healthy, active participants (9 men, 7 women; 23.5 ± 2.6 years, 72.1 ± 12.8 kg, 173.4 ± 10.7 cm) performed, in random order, four EQI contractions for knee extensions and flexions, respectively. EQI contractions were isotonically loaded to 70% of concentric (60°·s<sup>-1</sup>) maximal voluntary contraction. Rest between repetitions was set at three minutes, while four minutes separated each muscle group. Peak torque, mean torque, and optimal angle were evaluated pre- and post-bouts. Inter-repetition contraction time and angular velocity were also assessed.</p><p><strong>Results: </strong>Average torque was 160.9 ± 44.2 and 71.5 ± 23.2 Nm for the extensors and flexors. Peak and mean torque significantly decreased for both extensors (p < 0.001, d = 0.70-0.71) and flexors (p ≤ 0.022, d = 0.36) after EQI contractions, respectively. However, the optimal angle increased for extensors (p < 0.001, d = 1.00) but not flexors (p = 0.811, d = 0.06). During EQI contractions, knee flexors exhibited greater intra-repetition velocity than extensors (p = 0.002; η<sup>2</sup> = 0.50). Decreases in inter-repetition time and range of motion were more consistent for the extensors.</p><p><strong>Conclusions: </strong>Distinct responses exist when comparing EQI contractions of the knee extensors and flexors, particularly their effect on peak torque angles. These findings suggest knee flexors may require lower relative intensities to align more closely with extensor EQI contractions.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Exploring the biomechanics and fatigue patterns of eccentric quasi-isometric muscle actions in the knee extensors and flexors.\",\"authors\":\"Urška Ličen, Dustin J Oranchuk, Žiga Kozinc\",\"doi\":\"10.1007/s00421-024-05544-w\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>Eccentric quasi-isometric (EQI) resistance training is emerging as a promising option in sports medicine and rehabilitation. Despite prior research on EQI contractions in quadriceps and biceps brachii, their use in hamstring injury contexts is underexplored. Therefore, our study examines and contrasts the biomechanics and fatigue effects of EQI training on knee extensors and flexors.</p><p><strong>Methods: </strong>Following familiarization, 16 healthy, active participants (9 men, 7 women; 23.5 ± 2.6 years, 72.1 ± 12.8 kg, 173.4 ± 10.7 cm) performed, in random order, four EQI contractions for knee extensions and flexions, respectively. EQI contractions were isotonically loaded to 70% of concentric (60°·s<sup>-1</sup>) maximal voluntary contraction. Rest between repetitions was set at three minutes, while four minutes separated each muscle group. Peak torque, mean torque, and optimal angle were evaluated pre- and post-bouts. Inter-repetition contraction time and angular velocity were also assessed.</p><p><strong>Results: </strong>Average torque was 160.9 ± 44.2 and 71.5 ± 23.2 Nm for the extensors and flexors. Peak and mean torque significantly decreased for both extensors (p < 0.001, d = 0.70-0.71) and flexors (p ≤ 0.022, d = 0.36) after EQI contractions, respectively. However, the optimal angle increased for extensors (p < 0.001, d = 1.00) but not flexors (p = 0.811, d = 0.06). During EQI contractions, knee flexors exhibited greater intra-repetition velocity than extensors (p = 0.002; η<sup>2</sup> = 0.50). Decreases in inter-repetition time and range of motion were more consistent for the extensors.</p><p><strong>Conclusions: </strong>Distinct responses exist when comparing EQI contractions of the knee extensors and flexors, particularly their effect on peak torque angles. These findings suggest knee flexors may require lower relative intensities to align more closely with extensor EQI contractions.</p>\",\"PeriodicalId\":2,\"journal\":{\"name\":\"ACS Applied Bio Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Bio Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1007/s00421-024-05544-w\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/7/2 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"MATERIALS SCIENCE, BIOMATERIALS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00421-024-05544-w","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/7/2 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

摘要

目的:偏心准等长(EQI)阻力训练正逐渐成为运动医学和康复中的一种有前途的选择。尽管之前对股四头肌和肱二头肌的 EQI 收缩进行了研究,但在腿筋受伤的情况下使用 EQI 的研究还不充分。因此,我们的研究考察并对比了 EQI 训练对膝关节伸肌和屈肌的生物力学和疲劳效应:熟悉后,16 名健康、活跃的参与者(9 名男性,7 名女性;23.5 ± 2.6 岁,72.1 ± 12.8 千克,173.4 ± 10.7 厘米)以随机顺序分别进行了四次伸膝和屈膝的 EQI 收缩。EQI 收缩的负荷为同心(60°-s-1)最大自主收缩的 70%。重复之间的休息时间定为三分钟,每组肌肉之间的休息时间为四分钟。比赛前后对峰值扭矩、平均扭矩和最佳角度进行评估。此外,还评估了重复间收缩时间和角速度:结果:伸肌和屈肌的平均扭矩分别为 160.9 ± 44.2 牛米和 71.5 ± 23.2 牛米。两个伸肌的峰值扭矩和平均扭矩都明显下降(p 2 = 0.50)。伸肌的重复间歇时间和活动范围的减少更为一致:在比较膝关节伸肌和屈肌的 EQI 收缩时,存在不同的反应,尤其是对峰值扭矩角的影响。这些研究结果表明,膝关节屈肌可能需要较低的相对强度,才能与伸肌的 EQI 收缩更接近。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Exploring the biomechanics and fatigue patterns of eccentric quasi-isometric muscle actions in the knee extensors and flexors.

Exploring the biomechanics and fatigue patterns of eccentric quasi-isometric muscle actions in the knee extensors and flexors.

Purpose: Eccentric quasi-isometric (EQI) resistance training is emerging as a promising option in sports medicine and rehabilitation. Despite prior research on EQI contractions in quadriceps and biceps brachii, their use in hamstring injury contexts is underexplored. Therefore, our study examines and contrasts the biomechanics and fatigue effects of EQI training on knee extensors and flexors.

Methods: Following familiarization, 16 healthy, active participants (9 men, 7 women; 23.5 ± 2.6 years, 72.1 ± 12.8 kg, 173.4 ± 10.7 cm) performed, in random order, four EQI contractions for knee extensions and flexions, respectively. EQI contractions were isotonically loaded to 70% of concentric (60°·s-1) maximal voluntary contraction. Rest between repetitions was set at three minutes, while four minutes separated each muscle group. Peak torque, mean torque, and optimal angle were evaluated pre- and post-bouts. Inter-repetition contraction time and angular velocity were also assessed.

Results: Average torque was 160.9 ± 44.2 and 71.5 ± 23.2 Nm for the extensors and flexors. Peak and mean torque significantly decreased for both extensors (p < 0.001, d = 0.70-0.71) and flexors (p ≤ 0.022, d = 0.36) after EQI contractions, respectively. However, the optimal angle increased for extensors (p < 0.001, d = 1.00) but not flexors (p = 0.811, d = 0.06). During EQI contractions, knee flexors exhibited greater intra-repetition velocity than extensors (p = 0.002; η2 = 0.50). Decreases in inter-repetition time and range of motion were more consistent for the extensors.

Conclusions: Distinct responses exist when comparing EQI contractions of the knee extensors and flexors, particularly their effect on peak torque angles. These findings suggest knee flexors may require lower relative intensities to align more closely with extensor EQI contractions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信