{"title":"对室温下全血过夜(18-24 小时)后用不同方法制备的血小板浓缩物进行评估。","authors":"Deviprasanna Mohanty, Rahul Chaurasia, Anand Kumar, Gopal Kumar Patidar, Hem Chandra Pandey, Arulselvi Subramanian","doi":"10.1111/tme.13064","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objectives: </strong>Regulatory requirement of fixed holding time (6 h) of whole blood (WB) at room temperature, that is, 22-24°C (RT) results in sub-optimal component separation. The aim was to evaluate the platelet concentrates (PC) prepared by both platelet rich plasma (PRP) and buffy coat (BC) methods after overnight hold (18-24 h) at RT.</p><p><strong>Materials and methods: </strong>A prospective experimental study was performed. A total of 48 WB units collected were divided into four groups (12 each) control-1 (C1) and test-1 (T1) for PRP and control-2 (C2) and test-2 (T2) for the BC method. Control groups were processed within 6 h, and in test groups, components were prepared after overnight hold, followed by evaluation of quality parameters.</p><p><strong>Results: </strong>Irrespective of the method used, all PCs had similar volume, platelet yield, swirling, no bacterial contamination, RBC contamination, PaO<sub>2</sub> and PaCO<sub>2</sub> levels. PCs in the T1 group had significant differences in glucose and MPV values on d1, which were resolved by d5 of storage. PCs in T2 has significant differences in pH, glucose, and MPV levels throughout storage. PRBC in test and control groups had similar quality parameters till d42 of storage. FFPs in all tests were noninferior to the concurrent control groups till 3 months of storage.</p><p><strong>Conclusion: </strong>Overnight holding of WB had no lasting deleterious changes. Though a few biochemical parameters in the test groups were significantly different, they can be accepted to improve the logistics of component separation. Overall PRP method seemed to have a better result than the BC method after an overnight hold.</p>","PeriodicalId":23306,"journal":{"name":"Transfusion Medicine","volume":" ","pages":"311-318"},"PeriodicalIF":1.5000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of platelet concentrates prepared using different methods after overnight holding (18-24 h) of whole blood at room temperature.\",\"authors\":\"Deviprasanna Mohanty, Rahul Chaurasia, Anand Kumar, Gopal Kumar Patidar, Hem Chandra Pandey, Arulselvi Subramanian\",\"doi\":\"10.1111/tme.13064\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objectives: </strong>Regulatory requirement of fixed holding time (6 h) of whole blood (WB) at room temperature, that is, 22-24°C (RT) results in sub-optimal component separation. The aim was to evaluate the platelet concentrates (PC) prepared by both platelet rich plasma (PRP) and buffy coat (BC) methods after overnight hold (18-24 h) at RT.</p><p><strong>Materials and methods: </strong>A prospective experimental study was performed. A total of 48 WB units collected were divided into four groups (12 each) control-1 (C1) and test-1 (T1) for PRP and control-2 (C2) and test-2 (T2) for the BC method. Control groups were processed within 6 h, and in test groups, components were prepared after overnight hold, followed by evaluation of quality parameters.</p><p><strong>Results: </strong>Irrespective of the method used, all PCs had similar volume, platelet yield, swirling, no bacterial contamination, RBC contamination, PaO<sub>2</sub> and PaCO<sub>2</sub> levels. PCs in the T1 group had significant differences in glucose and MPV values on d1, which were resolved by d5 of storage. PCs in T2 has significant differences in pH, glucose, and MPV levels throughout storage. PRBC in test and control groups had similar quality parameters till d42 of storage. FFPs in all tests were noninferior to the concurrent control groups till 3 months of storage.</p><p><strong>Conclusion: </strong>Overnight holding of WB had no lasting deleterious changes. Though a few biochemical parameters in the test groups were significantly different, they can be accepted to improve the logistics of component separation. Overall PRP method seemed to have a better result than the BC method after an overnight hold.</p>\",\"PeriodicalId\":23306,\"journal\":{\"name\":\"Transfusion Medicine\",\"volume\":\" \",\"pages\":\"311-318\"},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Transfusion Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/tme.13064\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/30 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"HEMATOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Transfusion Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/tme.13064","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/30 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"HEMATOLOGY","Score":null,"Total":0}
Evaluation of platelet concentrates prepared using different methods after overnight holding (18-24 h) of whole blood at room temperature.
Background and objectives: Regulatory requirement of fixed holding time (6 h) of whole blood (WB) at room temperature, that is, 22-24°C (RT) results in sub-optimal component separation. The aim was to evaluate the platelet concentrates (PC) prepared by both platelet rich plasma (PRP) and buffy coat (BC) methods after overnight hold (18-24 h) at RT.
Materials and methods: A prospective experimental study was performed. A total of 48 WB units collected were divided into four groups (12 each) control-1 (C1) and test-1 (T1) for PRP and control-2 (C2) and test-2 (T2) for the BC method. Control groups were processed within 6 h, and in test groups, components were prepared after overnight hold, followed by evaluation of quality parameters.
Results: Irrespective of the method used, all PCs had similar volume, platelet yield, swirling, no bacterial contamination, RBC contamination, PaO2 and PaCO2 levels. PCs in the T1 group had significant differences in glucose and MPV values on d1, which were resolved by d5 of storage. PCs in T2 has significant differences in pH, glucose, and MPV levels throughout storage. PRBC in test and control groups had similar quality parameters till d42 of storage. FFPs in all tests were noninferior to the concurrent control groups till 3 months of storage.
Conclusion: Overnight holding of WB had no lasting deleterious changes. Though a few biochemical parameters in the test groups were significantly different, they can be accepted to improve the logistics of component separation. Overall PRP method seemed to have a better result than the BC method after an overnight hold.
期刊介绍:
Transfusion Medicine publishes articles on transfusion medicine in its widest context, including blood transfusion practice (blood procurement, pharmaceutical, clinical, scientific, computing and documentary aspects), immunohaematology, immunogenetics, histocompatibility, medico-legal applications, and related molecular biology and biotechnology.
In addition to original articles, which may include brief communications and case reports, the journal contains a regular educational section (based on invited reviews and state-of-the-art reports), technical section (including quality assurance and current practice guidelines), leading articles, letters to the editor, occasional historical articles and signed book reviews. Some lectures from Society meetings that are likely to be of general interest to readers of the Journal may be published at the discretion of the Editor and subject to the availability of space in the Journal.