{"title":"在 NMIJ/AIST 为 1 keV 至 20 MeV 标准中子场设计长计数器的模拟研究。","authors":"Tetsuro Matsumoto, Akihiko Masuda, Hideki Harano, Seiya Manabe","doi":"10.1093/rpd/ncae151","DOIUrl":null,"url":null,"abstract":"<p><p>A De-Pangher-type long counter was designed for neutron measurements in standard neutron fields based on the results of simulations using the MCNP6 code at the National Metrology Institute of Japan, the National Institute of Advanced Industrial Science and Technology. The effects of six parameters in the design on the energy response of the long counter were investigated. The energy response was then quantitatively evaluated for eight design candidates selected from the investigation. The calculation results show that these candidates have a flatter energy response from 100 eV to 10 MeV compared to that of the current long counter. These candidates also reduce the difference between the average energy response from 10 eV to 1 MeV and that from 10 to 20 MeV.</p>","PeriodicalId":20795,"journal":{"name":"Radiation protection dosimetry","volume":null,"pages":null},"PeriodicalIF":0.8000,"publicationDate":"2024-08-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Simulation study for design of long counter for standard neutron fields from 1 keV to 20 MeV at NMIJ/AIST.\",\"authors\":\"Tetsuro Matsumoto, Akihiko Masuda, Hideki Harano, Seiya Manabe\",\"doi\":\"10.1093/rpd/ncae151\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A De-Pangher-type long counter was designed for neutron measurements in standard neutron fields based on the results of simulations using the MCNP6 code at the National Metrology Institute of Japan, the National Institute of Advanced Industrial Science and Technology. The effects of six parameters in the design on the energy response of the long counter were investigated. The energy response was then quantitatively evaluated for eight design candidates selected from the investigation. The calculation results show that these candidates have a flatter energy response from 100 eV to 10 MeV compared to that of the current long counter. These candidates also reduce the difference between the average energy response from 10 eV to 1 MeV and that from 10 to 20 MeV.</p>\",\"PeriodicalId\":20795,\"journal\":{\"name\":\"Radiation protection dosimetry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-08-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Radiation protection dosimetry\",\"FirstCategoryId\":\"93\",\"ListUrlMain\":\"https://doi.org/10.1093/rpd/ncae151\",\"RegionNum\":4,\"RegionCategory\":\"环境科学与生态学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ENVIRONMENTAL SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Radiation protection dosimetry","FirstCategoryId":"93","ListUrlMain":"https://doi.org/10.1093/rpd/ncae151","RegionNum":4,"RegionCategory":"环境科学与生态学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENVIRONMENTAL SCIENCES","Score":null,"Total":0}
Simulation study for design of long counter for standard neutron fields from 1 keV to 20 MeV at NMIJ/AIST.
A De-Pangher-type long counter was designed for neutron measurements in standard neutron fields based on the results of simulations using the MCNP6 code at the National Metrology Institute of Japan, the National Institute of Advanced Industrial Science and Technology. The effects of six parameters in the design on the energy response of the long counter were investigated. The energy response was then quantitatively evaluated for eight design candidates selected from the investigation. The calculation results show that these candidates have a flatter energy response from 100 eV to 10 MeV compared to that of the current long counter. These candidates also reduce the difference between the average energy response from 10 eV to 1 MeV and that from 10 to 20 MeV.
期刊介绍:
Radiation Protection Dosimetry covers all aspects of personal and environmental dosimetry and monitoring, for both ionising and non-ionising radiations. This includes biological aspects, physical concepts, biophysical dosimetry, external and internal personal dosimetry and monitoring, environmental and workplace monitoring, accident dosimetry, and dosimetry related to the protection of patients. Particular emphasis is placed on papers covering the fundamentals of dosimetry; units, radiation quantities and conversion factors. Papers covering archaeological dating are included only if the fundamental measurement method or technique, such as thermoluminescence, has direct application to personal dosimetry measurements. Papers covering the dosimetric aspects of radon or other naturally occurring radioactive materials and low level radiation are included. Animal experiments and ecological sample measurements are not included unless there is a significant relevant content reason.