认知能力正常的老年人在连续两晚的实验室多导睡眠监测中慢波睡眠和脑电图振荡的稳定性。

IF 3.4 3区 医学 Q2 CLINICAL NEUROLOGY
Anna E Mullins, Shayna Pehel, Ankit Parekh, Korey Kam, Omonigho M Bubu, Thomas M Tolbert, David M Rapoport, Indu Ayappa, Andrew W Varga, Ricardo S Osorio
{"title":"认知能力正常的老年人在连续两晚的实验室多导睡眠监测中慢波睡眠和脑电图振荡的稳定性。","authors":"Anna E Mullins, Shayna Pehel, Ankit Parekh, Korey Kam, Omonigho M Bubu, Thomas M Tolbert, David M Rapoport, Indu Ayappa, Andrew W Varga, Ricardo S Osorio","doi":"10.1111/jsr.14281","DOIUrl":null,"url":null,"abstract":"<p><p>Laboratory polysomnography provides gold-standard measures of sleep physiology, but multi-night investigations are resource intensive. We assessed the night-to-night stability via reproducibility metrics for sleep macrostructure and electroencephalography oscillations in a group of cognitively normal adults attending two consecutive polysomnographies. Electroencephalographies were analysed using an automatic algorithm for detection of slow-wave activity, spindle and K-complex densities. Average differences between nights for sleep macrostructure, electroencephalography oscillations and sleep apnea severity were assessed, and test-retest reliability was determined using two-way intraclass correlations. Agreement was calculated using the smallest real differences between nights for all measures. Night 2 polysomnographies showed significantly greater time in bed, total sleep time (6.3 hr versus 6.8 hr, p < 0.001) and percentage of rapid eye movement sleep (17.5 versus 19.7, p < 0.001). Intraclass correlations were low for total sleep time, percentage of rapid eye movement sleep and sleep efficiency, moderate for percentage of slow-wave sleep and percentage of non-rapid eye movement 2 sleep, good for slow-wave activity and K-complex densities, and excellent for spindles and apnea-hypopnea index with hypopneas defined according to 4% oxygen desaturation criteria only. The smallest real difference values were proportionally high for most sleep macrostructure measures, indicating moderate agreement, and proportionally lower for most electroencephalography microstructure variables. Slow waves, K-complexes, spindles and apnea severity indices are highly reproducible across two consecutive nights of polysomnography. In contrast, sleep macrostructure measures all demonstrated poor reproducibility as indicated by low intraclass correlation values and moderate agreement. Although there were average differences in percentage of rapid eye movement sleep and total sleep time, these were numerically small and perhaps functionally or clinically less significant. One night of in-laboratory polysomnography is enough to provide stable, reproducible estimates of an individual's sleep concerning measures of slow-wave activity, spindles, K-complex densities and apnea severity.</p>","PeriodicalId":17057,"journal":{"name":"Journal of Sleep Research","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The stability of slow-wave sleep and EEG oscillations across two consecutive nights of laboratory polysomnography in cognitively normal older adults.\",\"authors\":\"Anna E Mullins, Shayna Pehel, Ankit Parekh, Korey Kam, Omonigho M Bubu, Thomas M Tolbert, David M Rapoport, Indu Ayappa, Andrew W Varga, Ricardo S Osorio\",\"doi\":\"10.1111/jsr.14281\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Laboratory polysomnography provides gold-standard measures of sleep physiology, but multi-night investigations are resource intensive. We assessed the night-to-night stability via reproducibility metrics for sleep macrostructure and electroencephalography oscillations in a group of cognitively normal adults attending two consecutive polysomnographies. Electroencephalographies were analysed using an automatic algorithm for detection of slow-wave activity, spindle and K-complex densities. Average differences between nights for sleep macrostructure, electroencephalography oscillations and sleep apnea severity were assessed, and test-retest reliability was determined using two-way intraclass correlations. Agreement was calculated using the smallest real differences between nights for all measures. Night 2 polysomnographies showed significantly greater time in bed, total sleep time (6.3 hr versus 6.8 hr, p < 0.001) and percentage of rapid eye movement sleep (17.5 versus 19.7, p < 0.001). Intraclass correlations were low for total sleep time, percentage of rapid eye movement sleep and sleep efficiency, moderate for percentage of slow-wave sleep and percentage of non-rapid eye movement 2 sleep, good for slow-wave activity and K-complex densities, and excellent for spindles and apnea-hypopnea index with hypopneas defined according to 4% oxygen desaturation criteria only. The smallest real difference values were proportionally high for most sleep macrostructure measures, indicating moderate agreement, and proportionally lower for most electroencephalography microstructure variables. Slow waves, K-complexes, spindles and apnea severity indices are highly reproducible across two consecutive nights of polysomnography. In contrast, sleep macrostructure measures all demonstrated poor reproducibility as indicated by low intraclass correlation values and moderate agreement. Although there were average differences in percentage of rapid eye movement sleep and total sleep time, these were numerically small and perhaps functionally or clinically less significant. One night of in-laboratory polysomnography is enough to provide stable, reproducible estimates of an individual's sleep concerning measures of slow-wave activity, spindles, K-complex densities and apnea severity.</p>\",\"PeriodicalId\":17057,\"journal\":{\"name\":\"Journal of Sleep Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Sleep Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/jsr.14281\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Sleep Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/jsr.14281","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

摘要

实验室多导睡眠图提供了衡量睡眠生理学的黄金标准,但多夜调查需要耗费大量资源。我们通过睡眠宏观结构和脑电图振荡的可重复性指标,评估了一组连续接受两次多导睡眠图检查的认知正常成年人每晚睡眠的稳定性。脑电图采用自动算法进行分析,以检测慢波活动、纺锤体和 K-复合体密度。评估了睡眠宏观结构、脑电图振荡和睡眠呼吸暂停严重程度的平均差异,并使用双向类内相关性确定了测试-重复测试的可靠性。所有测量指标的一致性均以各晚之间的最小实际差异来计算。第 2 夜的多导睡眠图显示,患者在床上的时间、总睡眠时间(6.3 小时对 6.8 小时,P
本文章由计算机程序翻译,如有差异,请以英文原文为准。
The stability of slow-wave sleep and EEG oscillations across two consecutive nights of laboratory polysomnography in cognitively normal older adults.

Laboratory polysomnography provides gold-standard measures of sleep physiology, but multi-night investigations are resource intensive. We assessed the night-to-night stability via reproducibility metrics for sleep macrostructure and electroencephalography oscillations in a group of cognitively normal adults attending two consecutive polysomnographies. Electroencephalographies were analysed using an automatic algorithm for detection of slow-wave activity, spindle and K-complex densities. Average differences between nights for sleep macrostructure, electroencephalography oscillations and sleep apnea severity were assessed, and test-retest reliability was determined using two-way intraclass correlations. Agreement was calculated using the smallest real differences between nights for all measures. Night 2 polysomnographies showed significantly greater time in bed, total sleep time (6.3 hr versus 6.8 hr, p < 0.001) and percentage of rapid eye movement sleep (17.5 versus 19.7, p < 0.001). Intraclass correlations were low for total sleep time, percentage of rapid eye movement sleep and sleep efficiency, moderate for percentage of slow-wave sleep and percentage of non-rapid eye movement 2 sleep, good for slow-wave activity and K-complex densities, and excellent for spindles and apnea-hypopnea index with hypopneas defined according to 4% oxygen desaturation criteria only. The smallest real difference values were proportionally high for most sleep macrostructure measures, indicating moderate agreement, and proportionally lower for most electroencephalography microstructure variables. Slow waves, K-complexes, spindles and apnea severity indices are highly reproducible across two consecutive nights of polysomnography. In contrast, sleep macrostructure measures all demonstrated poor reproducibility as indicated by low intraclass correlation values and moderate agreement. Although there were average differences in percentage of rapid eye movement sleep and total sleep time, these were numerically small and perhaps functionally or clinically less significant. One night of in-laboratory polysomnography is enough to provide stable, reproducible estimates of an individual's sleep concerning measures of slow-wave activity, spindles, K-complex densities and apnea severity.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Sleep Research
Journal of Sleep Research 医学-临床神经学
CiteScore
9.00
自引率
6.80%
发文量
234
审稿时长
6-12 weeks
期刊介绍: The Journal of Sleep Research is dedicated to basic and clinical sleep research. The Journal publishes original research papers and invited reviews in all areas of sleep research (including biological rhythms). The Journal aims to promote the exchange of ideas between basic and clinical sleep researchers coming from a wide range of backgrounds and disciplines. The Journal will achieve this by publishing papers which use multidisciplinary and novel approaches to answer important questions about sleep, as well as its disorders and the treatment thereof.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信