{"title":"在临床体外肺灌注过程中实时测量肺重量。","authors":"Ichiro Sakanoue, Toshihiro Okamoto, Kamal S Ayyat, James J Yun, Abdel Moneim Tantawi, Kenneth R McCurry","doi":"10.1016/j.healun.2024.06.013","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Real-time lung weight (LW) measurement is a simple and noninvasive technique for detecting extravascular lung water during ex vivo lung perfusion (EVLP). We investigated the feasibility of real-time LW measurement in clinical EVLP as a predictor of transplant suitability and post-transplant outcomes.</p><p><strong>Methods: </strong>In our clinical acellular EVLP protocol, real-time LW was measured in 117 EVLP cases from June 2019 to June 2022. The estimated LW gain at each time point was calculated using a scale placed under the organ chamber. The lungs were classified into 4 categories based on LW adjusted for height and compared between suitable and unsuitable cases. The relationship between estimated LW gain and primary graft dysfunction was also investigated.</p><p><strong>Results: </strong>The estimated LW gain during the EVLP significantly correlated with the LW gain (post-EVLP LW and pre-EVLP LW) measured on the back table (R<sup>2</sup> = 0.61, p < 0.01). In the adjusted LW categories 2 to 4, the estimated LW gain at 0-1 hour after EVLP was significantly higher in unsuitable cases than in suitable cases. The area under the curve for the estimated LW gain was ≥0.80. Primary graft dysfunction grades 0 to 1 had a significantly lower estimated LW gain at 60 minutes than grades 2 to 3 (-43 vs 1 g, p < 0.01).</p><p><strong>Conclusions: </strong>Real-time lung measurements can predict transplant suitability and post-transplant outcomes by the early detection of extravascular lung water during the initial 1 hour of EVLP.</p>","PeriodicalId":15900,"journal":{"name":"Journal of Heart and Lung Transplantation","volume":null,"pages":null},"PeriodicalIF":6.4000,"publicationDate":"2024-06-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Real-time lung weight measurement during clinical ex vivo lung perfusion.\",\"authors\":\"Ichiro Sakanoue, Toshihiro Okamoto, Kamal S Ayyat, James J Yun, Abdel Moneim Tantawi, Kenneth R McCurry\",\"doi\":\"10.1016/j.healun.2024.06.013\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Real-time lung weight (LW) measurement is a simple and noninvasive technique for detecting extravascular lung water during ex vivo lung perfusion (EVLP). We investigated the feasibility of real-time LW measurement in clinical EVLP as a predictor of transplant suitability and post-transplant outcomes.</p><p><strong>Methods: </strong>In our clinical acellular EVLP protocol, real-time LW was measured in 117 EVLP cases from June 2019 to June 2022. The estimated LW gain at each time point was calculated using a scale placed under the organ chamber. The lungs were classified into 4 categories based on LW adjusted for height and compared between suitable and unsuitable cases. The relationship between estimated LW gain and primary graft dysfunction was also investigated.</p><p><strong>Results: </strong>The estimated LW gain during the EVLP significantly correlated with the LW gain (post-EVLP LW and pre-EVLP LW) measured on the back table (R<sup>2</sup> = 0.61, p < 0.01). In the adjusted LW categories 2 to 4, the estimated LW gain at 0-1 hour after EVLP was significantly higher in unsuitable cases than in suitable cases. The area under the curve for the estimated LW gain was ≥0.80. Primary graft dysfunction grades 0 to 1 had a significantly lower estimated LW gain at 60 minutes than grades 2 to 3 (-43 vs 1 g, p < 0.01).</p><p><strong>Conclusions: </strong>Real-time lung measurements can predict transplant suitability and post-transplant outcomes by the early detection of extravascular lung water during the initial 1 hour of EVLP.</p>\",\"PeriodicalId\":15900,\"journal\":{\"name\":\"Journal of Heart and Lung Transplantation\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":6.4000,\"publicationDate\":\"2024-06-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Heart and Lung Transplantation\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1016/j.healun.2024.06.013\",\"RegionNum\":1,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Heart and Lung Transplantation","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.healun.2024.06.013","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

摘要

背景:实时肺重量(LW)测量是一种在体外肺灌注(EVLP)过程中检测血管外肺水分的简单无创技术。我们研究了在临床 EVLP 中实时测量肺重量作为移植适宜性和移植后预后预测指标的可行性:在我们的临床无细胞 EVLP 方案中,从 2019 年 6 月到 2022 年 6 月对 117 例 EVLP 进行了实时 LW 测量。使用放置在器官腔下的刻度计算每个时间点的估计LW增量。根据按身高调整后的肺活量将肺分为四类,并对适合和不适合的病例进行比较。此外,还研究了估计肺活量增加与原发性移植物功能障碍之间的关系:结果:EVLP期间估计的肺活量增加与在后台上测量的肺活量增加(EVLP后肺活量-EVLP前肺活量)显著相关(R2=0.61,PC结论:通过在EVLP最初1小时内早期检测血管外肺水,实时肺测量可预测移植适宜性和移植后预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-time lung weight measurement during clinical ex vivo lung perfusion.

Background: Real-time lung weight (LW) measurement is a simple and noninvasive technique for detecting extravascular lung water during ex vivo lung perfusion (EVLP). We investigated the feasibility of real-time LW measurement in clinical EVLP as a predictor of transplant suitability and post-transplant outcomes.

Methods: In our clinical acellular EVLP protocol, real-time LW was measured in 117 EVLP cases from June 2019 to June 2022. The estimated LW gain at each time point was calculated using a scale placed under the organ chamber. The lungs were classified into 4 categories based on LW adjusted for height and compared between suitable and unsuitable cases. The relationship between estimated LW gain and primary graft dysfunction was also investigated.

Results: The estimated LW gain during the EVLP significantly correlated with the LW gain (post-EVLP LW and pre-EVLP LW) measured on the back table (R2 = 0.61, p < 0.01). In the adjusted LW categories 2 to 4, the estimated LW gain at 0-1 hour after EVLP was significantly higher in unsuitable cases than in suitable cases. The area under the curve for the estimated LW gain was ≥0.80. Primary graft dysfunction grades 0 to 1 had a significantly lower estimated LW gain at 60 minutes than grades 2 to 3 (-43 vs 1 g, p < 0.01).

Conclusions: Real-time lung measurements can predict transplant suitability and post-transplant outcomes by the early detection of extravascular lung water during the initial 1 hour of EVLP.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
10.10
自引率
6.70%
发文量
1667
审稿时长
69 days
期刊介绍: The Journal of Heart and Lung Transplantation, the official publication of the International Society for Heart and Lung Transplantation, brings readers essential scholarly and timely information in the field of cardio-pulmonary transplantation, mechanical and biological support of the failing heart, advanced lung disease (including pulmonary vascular disease) and cell replacement therapy. Importantly, the journal also serves as a medium of communication of pre-clinical sciences in all these rapidly expanding areas.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信