Pooja Muralidharan , Ravi Sankaran , Perraju Bendapudi , C. Santhosh Kumar , A. Anand Kumar
{"title":"心电图中的人工智能:验证非卧床半身像标记和预测器。","authors":"Pooja Muralidharan , Ravi Sankaran , Perraju Bendapudi , C. Santhosh Kumar , A. Anand Kumar","doi":"10.1016/j.eplepsyres.2024.107403","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>Early prediction of epileptic seizures can help reduce morbidity and mortality. In this work, we explore using electrocardiographic (ECG) signal as input to a seizure prediction system and note that the performance can be improved by using selected signal processing techniques.</p></div><div><h3>Methods</h3><p>We used frequency domain analysis with a deep neural network backend for all our experiments in this work. We further analysed the effect of the proposed system for different seizure semiologies and prediction horizons. We explored refining the signal using signal processing to enhance the system's performance.</p></div><div><h3>Results</h3><p>Our final system using the Temple University Hospital’s Seizure (TUHSZ) corpus gave an overall prediction accuracy of 84.02 %, sensitivity of 87.59 %, specificity of 81.9 %, and an area under the receiver operating characteristic curve (AUROC) of 0.9112. Notably, these results surpassed the state-of-the-art outcomes reported using the TUHSZ database; all findings are statistically significant. We also validated our study using the Siena scalp EEG database. Using the frequency domain data, our baseline system gave a performance of 75.17 %, 79.17 %, 70.04 % and 0.82 for prediction accuracy, sensitivity, specificity and AUROC, respectively. After selecting the optimal frequency band of 0.8–15 Hz, we obtained a performance of 80.49 %, 89.51 %, 75.23 % and 0.89 for prediction accuracy, sensitivity, specificity and AUROC, respectively which is an improvement of 5.32 %, 10.34 %, 5.19 % and 0.08 for prediction accuracy, sensitivity, specificity and AUROC, respectively.</p></div><div><h3>Conclusions</h3><p>The seizure information in ECG is concentrated in a narrow frequency band. Identifying and selecting that band can help improve the performance of seizure detection and prediction.</p></div><div><h3>Significance</h3><p>EEG is susceptible to artefacts and is not preferred in a low-cost ambulatory device. ECG can be used in wearable devices (like chest bands) and is feasible for developing a low-cost ambulatory device for seizure prediction. Early seizure prediction can provide patients and clinicians with the required alert to take necessary precautions and prevent a fatality, significantly improving the patient’s quality of life.</p></div>","PeriodicalId":11914,"journal":{"name":"Epilepsy Research","volume":"204 ","pages":"Article 107403"},"PeriodicalIF":2.0000,"publicationDate":"2024-06-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"AI in ECG: Validating an ambulatory semiology labeller and predictor\",\"authors\":\"Pooja Muralidharan , Ravi Sankaran , Perraju Bendapudi , C. Santhosh Kumar , A. Anand Kumar\",\"doi\":\"10.1016/j.eplepsyres.2024.107403\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Objectives</h3><p>Early prediction of epileptic seizures can help reduce morbidity and mortality. In this work, we explore using electrocardiographic (ECG) signal as input to a seizure prediction system and note that the performance can be improved by using selected signal processing techniques.</p></div><div><h3>Methods</h3><p>We used frequency domain analysis with a deep neural network backend for all our experiments in this work. We further analysed the effect of the proposed system for different seizure semiologies and prediction horizons. We explored refining the signal using signal processing to enhance the system's performance.</p></div><div><h3>Results</h3><p>Our final system using the Temple University Hospital’s Seizure (TUHSZ) corpus gave an overall prediction accuracy of 84.02 %, sensitivity of 87.59 %, specificity of 81.9 %, and an area under the receiver operating characteristic curve (AUROC) of 0.9112. Notably, these results surpassed the state-of-the-art outcomes reported using the TUHSZ database; all findings are statistically significant. We also validated our study using the Siena scalp EEG database. Using the frequency domain data, our baseline system gave a performance of 75.17 %, 79.17 %, 70.04 % and 0.82 for prediction accuracy, sensitivity, specificity and AUROC, respectively. After selecting the optimal frequency band of 0.8–15 Hz, we obtained a performance of 80.49 %, 89.51 %, 75.23 % and 0.89 for prediction accuracy, sensitivity, specificity and AUROC, respectively which is an improvement of 5.32 %, 10.34 %, 5.19 % and 0.08 for prediction accuracy, sensitivity, specificity and AUROC, respectively.</p></div><div><h3>Conclusions</h3><p>The seizure information in ECG is concentrated in a narrow frequency band. Identifying and selecting that band can help improve the performance of seizure detection and prediction.</p></div><div><h3>Significance</h3><p>EEG is susceptible to artefacts and is not preferred in a low-cost ambulatory device. ECG can be used in wearable devices (like chest bands) and is feasible for developing a low-cost ambulatory device for seizure prediction. Early seizure prediction can provide patients and clinicians with the required alert to take necessary precautions and prevent a fatality, significantly improving the patient’s quality of life.</p></div>\",\"PeriodicalId\":11914,\"journal\":{\"name\":\"Epilepsy Research\",\"volume\":\"204 \",\"pages\":\"Article 107403\"},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2024-06-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Epilepsy Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0920121124001189\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Epilepsy Research","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0920121124001189","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
AI in ECG: Validating an ambulatory semiology labeller and predictor
Objectives
Early prediction of epileptic seizures can help reduce morbidity and mortality. In this work, we explore using electrocardiographic (ECG) signal as input to a seizure prediction system and note that the performance can be improved by using selected signal processing techniques.
Methods
We used frequency domain analysis with a deep neural network backend for all our experiments in this work. We further analysed the effect of the proposed system for different seizure semiologies and prediction horizons. We explored refining the signal using signal processing to enhance the system's performance.
Results
Our final system using the Temple University Hospital’s Seizure (TUHSZ) corpus gave an overall prediction accuracy of 84.02 %, sensitivity of 87.59 %, specificity of 81.9 %, and an area under the receiver operating characteristic curve (AUROC) of 0.9112. Notably, these results surpassed the state-of-the-art outcomes reported using the TUHSZ database; all findings are statistically significant. We also validated our study using the Siena scalp EEG database. Using the frequency domain data, our baseline system gave a performance of 75.17 %, 79.17 %, 70.04 % and 0.82 for prediction accuracy, sensitivity, specificity and AUROC, respectively. After selecting the optimal frequency band of 0.8–15 Hz, we obtained a performance of 80.49 %, 89.51 %, 75.23 % and 0.89 for prediction accuracy, sensitivity, specificity and AUROC, respectively which is an improvement of 5.32 %, 10.34 %, 5.19 % and 0.08 for prediction accuracy, sensitivity, specificity and AUROC, respectively.
Conclusions
The seizure information in ECG is concentrated in a narrow frequency band. Identifying and selecting that band can help improve the performance of seizure detection and prediction.
Significance
EEG is susceptible to artefacts and is not preferred in a low-cost ambulatory device. ECG can be used in wearable devices (like chest bands) and is feasible for developing a low-cost ambulatory device for seizure prediction. Early seizure prediction can provide patients and clinicians with the required alert to take necessary precautions and prevent a fatality, significantly improving the patient’s quality of life.
期刊介绍:
Epilepsy Research provides for publication of high quality articles in both basic and clinical epilepsy research, with a special emphasis on translational research that ultimately relates to epilepsy as a human condition. The journal is intended to provide a forum for reporting the best and most rigorous epilepsy research from all disciplines ranging from biophysics and molecular biology to epidemiological and psychosocial research. As such the journal will publish original papers relevant to epilepsy from any scientific discipline and also studies of a multidisciplinary nature. Clinical and experimental research papers adopting fresh conceptual approaches to the study of epilepsy and its treatment are encouraged. The overriding criteria for publication are novelty, significant clinical or experimental relevance, and interest to a multidisciplinary audience in the broad arena of epilepsy. Review articles focused on any topic of epilepsy research will also be considered, but only if they present an exceptionally clear synthesis of current knowledge and future directions of a research area, based on a critical assessment of the available data or on hypotheses that are likely to stimulate more critical thinking and further advances in an area of epilepsy research.