Barsha Lal, David Alonso-Caneiro, Scott A Read, Andrew Carkeet
{"title":"健康儿童和青少年视网膜和脉络膜光学相干断层血管造影指数的可重复性。","authors":"Barsha Lal, David Alonso-Caneiro, Scott A Read, Andrew Carkeet","doi":"10.1111/opo.13357","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the repeatability of retinal and choroidal optical coherence tomography angiography (OCT-A) indices among healthy children and compare it to healthy young adults.</p><p><strong>Methods: </strong>This prospective study captured 3 mm × 3 mm and 6 mm × 6 mm macular OCT-A scans including superficial and deep retinal layers, choriocapillaris and deep choroid over two visits, 1 week apart at approximately the same time of day, for 22 healthy adults (18-30 years) and 21 children (6-15 years). Magnification and projection-artefact corrected indices extracted using a custom image analysis program and individual biometry were compared between visits using Bland-Altman analysis and intraclass correlation (ICC). Retinal indices included foveal avascular zone metrics, perfusion and vessel density and choroidal indices included choriocapillaris flow deficit metrics and deep choroid perfusion density, in the foveal, parafoveal and perifoveal regions. Repeatability between adults and children was compared with F-test.</p><p><strong>Results: </strong>Bland-Altman analysis showed that the mean differences between repeated OCT-A indices were not significantly different from zero for either of the zones, layers and scan sizes in the two age groups (p > 0.05) except for foveal vessel density and foveal avascular zone perimeter (p = 0.04 for both) of 6-mm-deep retinal layer scans. The ICC ranged between 0.67 and 0.99. Significantly higher variability between visits (p < 0.05) in the indices was noted among adults than children, especially for choroidal indices of larger scan size.</p><p><strong>Conclusion: </strong>The retinal and choroidal OCT-A indices in the foveal, parafoveal and perifoveal zones were repeatable in healthy children except for the foveal vessel density and foveal avascular zone perimeter of the 6-mm-deep retinal layer, which exhibited statistically borderline differences between visits. The adult group showed more variability between visits compared to children, especially in the larger scan size for choroidal OCT-A indices.</p>","PeriodicalId":19522,"journal":{"name":"Ophthalmic and Physiological Optics","volume":" ","pages":"1114-1127"},"PeriodicalIF":2.8000,"publicationDate":"2024-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Repeatability of retinal and choroidal optical coherence tomography angiography indices in healthy children and young adults.\",\"authors\":\"Barsha Lal, David Alonso-Caneiro, Scott A Read, Andrew Carkeet\",\"doi\":\"10.1111/opo.13357\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the repeatability of retinal and choroidal optical coherence tomography angiography (OCT-A) indices among healthy children and compare it to healthy young adults.</p><p><strong>Methods: </strong>This prospective study captured 3 mm × 3 mm and 6 mm × 6 mm macular OCT-A scans including superficial and deep retinal layers, choriocapillaris and deep choroid over two visits, 1 week apart at approximately the same time of day, for 22 healthy adults (18-30 years) and 21 children (6-15 years). Magnification and projection-artefact corrected indices extracted using a custom image analysis program and individual biometry were compared between visits using Bland-Altman analysis and intraclass correlation (ICC). Retinal indices included foveal avascular zone metrics, perfusion and vessel density and choroidal indices included choriocapillaris flow deficit metrics and deep choroid perfusion density, in the foveal, parafoveal and perifoveal regions. Repeatability between adults and children was compared with F-test.</p><p><strong>Results: </strong>Bland-Altman analysis showed that the mean differences between repeated OCT-A indices were not significantly different from zero for either of the zones, layers and scan sizes in the two age groups (p > 0.05) except for foveal vessel density and foveal avascular zone perimeter (p = 0.04 for both) of 6-mm-deep retinal layer scans. The ICC ranged between 0.67 and 0.99. Significantly higher variability between visits (p < 0.05) in the indices was noted among adults than children, especially for choroidal indices of larger scan size.</p><p><strong>Conclusion: </strong>The retinal and choroidal OCT-A indices in the foveal, parafoveal and perifoveal zones were repeatable in healthy children except for the foveal vessel density and foveal avascular zone perimeter of the 6-mm-deep retinal layer, which exhibited statistically borderline differences between visits. The adult group showed more variability between visits compared to children, especially in the larger scan size for choroidal OCT-A indices.</p>\",\"PeriodicalId\":19522,\"journal\":{\"name\":\"Ophthalmic and Physiological Optics\",\"volume\":\" \",\"pages\":\"1114-1127\"},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic and Physiological Optics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1111/opo.13357\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic and Physiological Optics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.13357","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0
摘要
目的:评估健康儿童视网膜和脉络膜光学相干断层血管成像(OCT-A)指数的可重复性,并将其与健康年轻成人进行比较:这项前瞻性研究采集了 22 名健康成人(18-30 岁)和 21 名儿童(6-15 岁)的 3 mm × 3 mm 和 6 mm × 6 mm 黄斑 OCT-A 扫描图像,包括视网膜浅层和深层、脉络膜和脉络膜深层。使用定制的图像分析程序提取放大和投影图像误差校正指数,并使用布兰-阿尔特曼分析和类内相关性(ICC)比较各次检查的个体生物测量值。视网膜指数包括眼窝无血管区指标、灌注和血管密度,脉络膜指数包括眼窝、眼窝旁和眼窝周围区域的绒毛膜血流缺损指标和深脉络膜灌注密度。用 F 检验比较了成人和儿童之间的重复性:Bland-Altman分析表明,除了6毫米深视网膜层扫描的眼窝血管密度和眼窝无血管区周长(两者的P = 0.04)外,两个年龄组的重复OCT-A指数在区域、层和扫描尺寸上的平均差与零无显著差异(P > 0.05)。ICC 在 0.67 和 0.99 之间。各次检查之间的变异性显著较高(p 结论:视网膜和脉络膜视网膜扫描结果的ICC介于0.67和0.99之间:健康儿童眼窝、眼底旁和眼底周围的视网膜和脉络膜 OCT-A 指数具有可重复性,但 6 毫米深视网膜层的眼窝血管密度和眼窝无血管区周长除外,这两项指数在各次检查之间显示出统计学上的边缘性差异。与儿童相比,成人组在各次检查之间表现出更大的变异性,尤其是在扫描尺寸较大的脉络膜 OCT-A 指数方面。
Repeatability of retinal and choroidal optical coherence tomography angiography indices in healthy children and young adults.
Purpose: To evaluate the repeatability of retinal and choroidal optical coherence tomography angiography (OCT-A) indices among healthy children and compare it to healthy young adults.
Methods: This prospective study captured 3 mm × 3 mm and 6 mm × 6 mm macular OCT-A scans including superficial and deep retinal layers, choriocapillaris and deep choroid over two visits, 1 week apart at approximately the same time of day, for 22 healthy adults (18-30 years) and 21 children (6-15 years). Magnification and projection-artefact corrected indices extracted using a custom image analysis program and individual biometry were compared between visits using Bland-Altman analysis and intraclass correlation (ICC). Retinal indices included foveal avascular zone metrics, perfusion and vessel density and choroidal indices included choriocapillaris flow deficit metrics and deep choroid perfusion density, in the foveal, parafoveal and perifoveal regions. Repeatability between adults and children was compared with F-test.
Results: Bland-Altman analysis showed that the mean differences between repeated OCT-A indices were not significantly different from zero for either of the zones, layers and scan sizes in the two age groups (p > 0.05) except for foveal vessel density and foveal avascular zone perimeter (p = 0.04 for both) of 6-mm-deep retinal layer scans. The ICC ranged between 0.67 and 0.99. Significantly higher variability between visits (p < 0.05) in the indices was noted among adults than children, especially for choroidal indices of larger scan size.
Conclusion: The retinal and choroidal OCT-A indices in the foveal, parafoveal and perifoveal zones were repeatable in healthy children except for the foveal vessel density and foveal avascular zone perimeter of the 6-mm-deep retinal layer, which exhibited statistically borderline differences between visits. The adult group showed more variability between visits compared to children, especially in the larger scan size for choroidal OCT-A indices.
期刊介绍:
Ophthalmic & Physiological Optics, first published in 1925, is a leading international interdisciplinary journal that addresses basic and applied questions pertinent to contemporary research in vision science and optometry.
OPO publishes original research papers, technical notes, reviews and letters and will interest researchers, educators and clinicians concerned with the development, use and restoration of vision.