{"title":"通过脉搏波速度评估绝经后妇女的动脉僵化:无创设备之间的比较。","authors":"Lucimere Bohn, Jessica Rial-Vázquez, Iván Nine, María Rúa-Alonso, Juan Fariñas, Manuel Avelino Giráldez-García, Jorge Mota, Eliseo Iglesias-Soler","doi":"10.1097/GME.0000000000002383","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>This study aimed to ascertain the accuracy of measure arterial stiffness using the HUAWEI GT 3 Pro smartwatch and pOpmètre device against the SphygmoCor (algorithms: intersect tangent and maximum of the second derivate).</p><p><strong>Methods: </strong>Twenty-three physically active postmenopausal women (age: 58.9 ± 3.2 years; body mass index: 26.3 ± 4.8 kg/m 2 ) were recruited. Carotid-femoral pulse wave velocity, finger-toe pulse wave velocity, and wrist-finger pulse wave velocity were obtained using SphygmoCor, pOpmètre and HUAWEI GT 3 Pro devices in a randomized order. Additionally, the pulse mean carotid-femoral and finger-toe pulse transit time was registered for SphygmoCor and pOpmètre, respectively.</p><p><strong>Results: </strong>Lower values of pulse wave velocity were recorded by HUAWEI in comparison with SphygmoCor with both algorithms, whereas no significant differences were detected between SphygmoCor and pOpmètre results. Pulse wave velocity values from SphygmoCor were positively correlated with pOpmètre results ( r = 0.464 and r = 0.451 using intersect tangent and second derivative algorithms), whereas this was not the case with those obtained from HUAWEI. Coefficients of bias of Lin's concordance coefficients close to 1 (0.832 and 0.831 for intersect tangent and second derivative algorithm, respectively) and mean bias close to 0 from Bland-Altman analysis suggested an acceptable agreement between pulse wave velocity obtained from SphygmoCor and pOpmètre.</p><p><strong>Conclusions: </strong>Our results suggest an acceptable concordance of pulse wave velocity values recoded by SphygmoCor and pOpmètre, whereas this was not the case for data obtained from HUAWEI GT 3 Pro smartwatch. Therefore, the pOpmètre may be a viable alternative for assessing arterial stiffness, but measurement via the smartwatch device cannot be recommended.</p>","PeriodicalId":18435,"journal":{"name":"Menopause: The Journal of The North American Menopause Society","volume":null,"pages":null},"PeriodicalIF":2.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Arterial stiffness assessment by pulse wave velocity in postmenopausal women: comparison between noninvasive devices.\",\"authors\":\"Lucimere Bohn, Jessica Rial-Vázquez, Iván Nine, María Rúa-Alonso, Juan Fariñas, Manuel Avelino Giráldez-García, Jorge Mota, Eliseo Iglesias-Soler\",\"doi\":\"10.1097/GME.0000000000002383\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>This study aimed to ascertain the accuracy of measure arterial stiffness using the HUAWEI GT 3 Pro smartwatch and pOpmètre device against the SphygmoCor (algorithms: intersect tangent and maximum of the second derivate).</p><p><strong>Methods: </strong>Twenty-three physically active postmenopausal women (age: 58.9 ± 3.2 years; body mass index: 26.3 ± 4.8 kg/m 2 ) were recruited. Carotid-femoral pulse wave velocity, finger-toe pulse wave velocity, and wrist-finger pulse wave velocity were obtained using SphygmoCor, pOpmètre and HUAWEI GT 3 Pro devices in a randomized order. Additionally, the pulse mean carotid-femoral and finger-toe pulse transit time was registered for SphygmoCor and pOpmètre, respectively.</p><p><strong>Results: </strong>Lower values of pulse wave velocity were recorded by HUAWEI in comparison with SphygmoCor with both algorithms, whereas no significant differences were detected between SphygmoCor and pOpmètre results. Pulse wave velocity values from SphygmoCor were positively correlated with pOpmètre results ( r = 0.464 and r = 0.451 using intersect tangent and second derivative algorithms), whereas this was not the case with those obtained from HUAWEI. Coefficients of bias of Lin's concordance coefficients close to 1 (0.832 and 0.831 for intersect tangent and second derivative algorithm, respectively) and mean bias close to 0 from Bland-Altman analysis suggested an acceptable agreement between pulse wave velocity obtained from SphygmoCor and pOpmètre.</p><p><strong>Conclusions: </strong>Our results suggest an acceptable concordance of pulse wave velocity values recoded by SphygmoCor and pOpmètre, whereas this was not the case for data obtained from HUAWEI GT 3 Pro smartwatch. Therefore, the pOpmètre may be a viable alternative for assessing arterial stiffness, but measurement via the smartwatch device cannot be recommended.</p>\",\"PeriodicalId\":18435,\"journal\":{\"name\":\"Menopause: The Journal of The North American Menopause Society\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.8000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Menopause: The Journal of The North American Menopause Society\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1097/GME.0000000000002383\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/25 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"OBSTETRICS & GYNECOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Menopause: The Journal of The North American Menopause Society","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/GME.0000000000002383","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/25 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"OBSTETRICS & GYNECOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究旨在确定使用 HUAWEI GT 3 Pro 智能手表和 pOpmètre 设备与 SphygmoCor(算法:相切和二次导数的最大值)测量动脉僵化的准确性:招募了 23 名身体活跃的绝经后妇女(年龄:58.9 ± 3.2 岁;体重指数:26.3 ± 4.8 kg/m2)。使用 SphygmoCor、pOpmètre 和 HUAWEI GT 3 Pro 设备按随机顺序测量颈动脉-股动脉脉搏波速度、指趾脉搏波速度和腕指脉搏波速度。此外,SphygmoCor 和 pOpmètre 还分别记录了颈动脉-股动脉和指趾脉搏的平均通过时间:结果:在两种算法中,HUAWEI 记录的脉搏波速度值均低于 SphygmoCor,而 SphygmoCor 和 pOpmètre 的结果无明显差异。SphygmoCor 的脉搏波速度值与 pOpmètre 的结果呈正相关(使用相交正切和二阶导数算法,r = 0.464 和 r = 0.451),而 HUAWEI 的结果并非如此。林氏一致性系数的偏差接近 1(相切和二阶导数算法的偏差分别为 0.832 和 0.831),布兰-阿尔特曼分析的平均偏差接近 0,这表明 SphygmoCor 和 pOpmètre 获得的脉搏波速度之间的一致性是可以接受的:我们的研究结果表明,SphygmoCor 和 pOpmètre 重新编码的脉搏波速度值具有可接受的一致性,而 HUAWEI GT 3 Pro 智能手表获得的数据却并非如此。因此,pOpmètre 可能是评估动脉僵化的可行替代方法,但不推荐通过智能手表设备进行测量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Arterial stiffness assessment by pulse wave velocity in postmenopausal women: comparison between noninvasive devices.

Objective: This study aimed to ascertain the accuracy of measure arterial stiffness using the HUAWEI GT 3 Pro smartwatch and pOpmètre device against the SphygmoCor (algorithms: intersect tangent and maximum of the second derivate).

Methods: Twenty-three physically active postmenopausal women (age: 58.9 ± 3.2 years; body mass index: 26.3 ± 4.8 kg/m 2 ) were recruited. Carotid-femoral pulse wave velocity, finger-toe pulse wave velocity, and wrist-finger pulse wave velocity were obtained using SphygmoCor, pOpmètre and HUAWEI GT 3 Pro devices in a randomized order. Additionally, the pulse mean carotid-femoral and finger-toe pulse transit time was registered for SphygmoCor and pOpmètre, respectively.

Results: Lower values of pulse wave velocity were recorded by HUAWEI in comparison with SphygmoCor with both algorithms, whereas no significant differences were detected between SphygmoCor and pOpmètre results. Pulse wave velocity values from SphygmoCor were positively correlated with pOpmètre results ( r = 0.464 and r = 0.451 using intersect tangent and second derivative algorithms), whereas this was not the case with those obtained from HUAWEI. Coefficients of bias of Lin's concordance coefficients close to 1 (0.832 and 0.831 for intersect tangent and second derivative algorithm, respectively) and mean bias close to 0 from Bland-Altman analysis suggested an acceptable agreement between pulse wave velocity obtained from SphygmoCor and pOpmètre.

Conclusions: Our results suggest an acceptable concordance of pulse wave velocity values recoded by SphygmoCor and pOpmètre, whereas this was not the case for data obtained from HUAWEI GT 3 Pro smartwatch. Therefore, the pOpmètre may be a viable alternative for assessing arterial stiffness, but measurement via the smartwatch device cannot be recommended.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.40
自引率
7.40%
发文量
330
审稿时长
3-8 weeks
期刊介绍: ​Menopause, published monthly, provides a forum for new research, applied basic science, and clinical guidelines on all aspects of menopause. The scope and usefulness of the journal extend beyond gynecology, encompassing many varied biomedical areas, including internal medicine, family practice, medical subspecialties such as cardiology and geriatrics, epidemiology, pathology, sociology, psychology, anthropology, and pharmacology. This forum is essential to help integrate these areas, highlight needs for future research, and enhance health care.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信