{"title":"验证 \"佐贺摔伤风险模型\"。","authors":"Risa Hirata, Naoko E Katsuki, Shizuka Yaita, Eiji Nakatani, Hitomi Shimada, Yoshimasa Oda, Midori Tokushima, Hidetoshi Aihara, Motoshi Fujiwara, Masaki Tago","doi":"10.7150/ijms.92837","DOIUrl":null,"url":null,"abstract":"<p><p><b>Background:</b> Predicting fall injuries can mitigate the sequelae of falls and potentially utilize medical resources effectively. This study aimed to externally validate the accuracy of the Saga Fall Injury Risk Model (SFIRM), consisting of six factors including age, sex, emergency transport, medical referral letter, Bedriddenness Rank, and history of falls, assessed upon admission. <b>Methods:</b> This was a two-center, prospective, observational study. We included inpatients aged 20 years or older in two hospitals, an acute and a chronic care hospital, from October 2018 to September 2019. The predictive performance of the model was evaluated by calculating the area under the curve (AUC), 95% confidence interval (CI), and shrinkage coefficient of the entire study population. The minimum sample size of this study was 2,235 cases. <b>Results:</b> A total of 3,549 patients, with a median age of 78 years, were included in the analysis, and men accounted for 47.9% of all the patients. Among these, 35 (0.99%) had fall injuries. The performance of the SFIRM, as measured by the AUC, was 0.721 (95% CI: 0.662-0.781). The observed fall incidence closely aligned with the predicted incidence calculated using the SFIRM, with a shrinkage coefficient of 0.867. <b>Conclusions:</b> The external validation of the SFIRM in this two-center, prospective study showed good discrimination and calibration. This model can be easily applied upon admission and is valuable for fall injury prediction.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11186423/pdf/","citationCount":"0","resultStr":"{\"title\":\"Validation of the Saga Fall Injury Risk Model.\",\"authors\":\"Risa Hirata, Naoko E Katsuki, Shizuka Yaita, Eiji Nakatani, Hitomi Shimada, Yoshimasa Oda, Midori Tokushima, Hidetoshi Aihara, Motoshi Fujiwara, Masaki Tago\",\"doi\":\"10.7150/ijms.92837\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Background:</b> Predicting fall injuries can mitigate the sequelae of falls and potentially utilize medical resources effectively. This study aimed to externally validate the accuracy of the Saga Fall Injury Risk Model (SFIRM), consisting of six factors including age, sex, emergency transport, medical referral letter, Bedriddenness Rank, and history of falls, assessed upon admission. <b>Methods:</b> This was a two-center, prospective, observational study. We included inpatients aged 20 years or older in two hospitals, an acute and a chronic care hospital, from October 2018 to September 2019. The predictive performance of the model was evaluated by calculating the area under the curve (AUC), 95% confidence interval (CI), and shrinkage coefficient of the entire study population. The minimum sample size of this study was 2,235 cases. <b>Results:</b> A total of 3,549 patients, with a median age of 78 years, were included in the analysis, and men accounted for 47.9% of all the patients. Among these, 35 (0.99%) had fall injuries. The performance of the SFIRM, as measured by the AUC, was 0.721 (95% CI: 0.662-0.781). The observed fall incidence closely aligned with the predicted incidence calculated using the SFIRM, with a shrinkage coefficient of 0.867. <b>Conclusions:</b> The external validation of the SFIRM in this two-center, prospective study showed good discrimination and calibration. This model can be easily applied upon admission and is valuable for fall injury prediction.</p>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11186423/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.7150/ijms.92837\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.7150/ijms.92837","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Background: Predicting fall injuries can mitigate the sequelae of falls and potentially utilize medical resources effectively. This study aimed to externally validate the accuracy of the Saga Fall Injury Risk Model (SFIRM), consisting of six factors including age, sex, emergency transport, medical referral letter, Bedriddenness Rank, and history of falls, assessed upon admission. Methods: This was a two-center, prospective, observational study. We included inpatients aged 20 years or older in two hospitals, an acute and a chronic care hospital, from October 2018 to September 2019. The predictive performance of the model was evaluated by calculating the area under the curve (AUC), 95% confidence interval (CI), and shrinkage coefficient of the entire study population. The minimum sample size of this study was 2,235 cases. Results: A total of 3,549 patients, with a median age of 78 years, were included in the analysis, and men accounted for 47.9% of all the patients. Among these, 35 (0.99%) had fall injuries. The performance of the SFIRM, as measured by the AUC, was 0.721 (95% CI: 0.662-0.781). The observed fall incidence closely aligned with the predicted incidence calculated using the SFIRM, with a shrinkage coefficient of 0.867. Conclusions: The external validation of the SFIRM in this two-center, prospective study showed good discrimination and calibration. This model can be easily applied upon admission and is valuable for fall injury prediction.