{"title":"先进断层扫描对患膝关节金属装置患者的诊断效果:病例报告。","authors":"Yasushi Oshima, Tokifumi Majima","doi":"10.1272/jnms.JNMS.2025_92-101","DOIUrl":null,"url":null,"abstract":"<p><p>Simple radiography is the most frequently and widely available technology to examine bone pathologies. Computed tomography (CT) can evaluate pathologies more accurately in multiple planes and three dimensions; however, radiation exposure is much higher than with simple radiography. In addition, diagnostic ability is decreased for both technologies when metal devices are present. Tomosynthesis is a radiographic technology used to evaluate tissues quasi-three-dimensionally with less radiation exposure. Tomosynthesis technology was recently upgraded to reduce the effects of metal artifacts. This case report compares examination time, medical expense, image resolution, and radiation exposure for upgraded tomosynthesis, simple radiography, CT, and standard tomosynthesis in three patients with metal devices in the affected knees. Examination times were similar for the imaging technologies. Diagnostic performance was better for upgraded tomosynthesis than for simple radiography and standard tomosynthesis, and similar to that for CT. Moreover, radiation exposure and expense were higher for tomosynthesis than for simple radiography but lower than for CT. These findings suggest that upgraded tomosynthesis is the best method for evaluating bone pathology when metal devices are present and radiation exposure must be limited.</p>","PeriodicalId":56076,"journal":{"name":"Journal of Nippon Medical School","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2024-06-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Diagnostic performance of advanced tomosynthesis in patients with metal devices in the affected knee: a case report.\",\"authors\":\"Yasushi Oshima, Tokifumi Majima\",\"doi\":\"10.1272/jnms.JNMS.2025_92-101\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Simple radiography is the most frequently and widely available technology to examine bone pathologies. Computed tomography (CT) can evaluate pathologies more accurately in multiple planes and three dimensions; however, radiation exposure is much higher than with simple radiography. In addition, diagnostic ability is decreased for both technologies when metal devices are present. Tomosynthesis is a radiographic technology used to evaluate tissues quasi-three-dimensionally with less radiation exposure. Tomosynthesis technology was recently upgraded to reduce the effects of metal artifacts. This case report compares examination time, medical expense, image resolution, and radiation exposure for upgraded tomosynthesis, simple radiography, CT, and standard tomosynthesis in three patients with metal devices in the affected knees. Examination times were similar for the imaging technologies. Diagnostic performance was better for upgraded tomosynthesis than for simple radiography and standard tomosynthesis, and similar to that for CT. Moreover, radiation exposure and expense were higher for tomosynthesis than for simple radiography but lower than for CT. These findings suggest that upgraded tomosynthesis is the best method for evaluating bone pathology when metal devices are present and radiation exposure must be limited.</p>\",\"PeriodicalId\":56076,\"journal\":{\"name\":\"Journal of Nippon Medical School\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2024-06-18\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Nippon Medical School\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1272/jnms.JNMS.2025_92-101\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICINE, GENERAL & INTERNAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Nippon Medical School","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1272/jnms.JNMS.2025_92-101","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
Diagnostic performance of advanced tomosynthesis in patients with metal devices in the affected knee: a case report.
Simple radiography is the most frequently and widely available technology to examine bone pathologies. Computed tomography (CT) can evaluate pathologies more accurately in multiple planes and three dimensions; however, radiation exposure is much higher than with simple radiography. In addition, diagnostic ability is decreased for both technologies when metal devices are present. Tomosynthesis is a radiographic technology used to evaluate tissues quasi-three-dimensionally with less radiation exposure. Tomosynthesis technology was recently upgraded to reduce the effects of metal artifacts. This case report compares examination time, medical expense, image resolution, and radiation exposure for upgraded tomosynthesis, simple radiography, CT, and standard tomosynthesis in three patients with metal devices in the affected knees. Examination times were similar for the imaging technologies. Diagnostic performance was better for upgraded tomosynthesis than for simple radiography and standard tomosynthesis, and similar to that for CT. Moreover, radiation exposure and expense were higher for tomosynthesis than for simple radiography but lower than for CT. These findings suggest that upgraded tomosynthesis is the best method for evaluating bone pathology when metal devices are present and radiation exposure must be limited.
期刊介绍:
The international effort to understand, treat and control disease involve clinicians and researchers from many medical and biological science disciplines. The Journal of Nippon Medical School (JNMS) is the official journal of the Medical Association of Nippon Medical School and is dedicated to furthering international exchange of medical science experience and opinion. It provides an international forum for researchers in the fields of bascic and clinical medicine to introduce, discuss and exchange thier novel achievements in biomedical science and a platform for the worldwide dissemination and steering of biomedical knowledge for the benefit of human health and welfare. Properly reasoned discussions disciplined by appropriate references to existing bodies of knowledge or aimed at motivating the creation of such knowledge is the aim of the journal.