Kazuo Yachiune, Akira Suzuki, Yuta Saito, Masaki Tokuno, Masahito Kobayashi
{"title":"采用与油阻尼器相连的死区机构的隔震建筑物的地震响应特性","authors":"Kazuo Yachiune, Akira Suzuki, Yuta Saito, Masaki Tokuno, Masahito Kobayashi","doi":"10.1002/2475-8876.12448","DOIUrl":null,"url":null,"abstract":"<p>In recent years, there has been concern about the occurrence of extreme ground motions that greatly exceed the amplitude levels and durations expected at the conventional design level. Therefore, seismically isolated buildings are required to ensure seismic isolation performance for small earthquakes and suppress the excessive displacement of the seismic isolation layer for extreme ground motions. In this paper, we analyze the seismic response of seismically isolated buildings with the dead zone mechanism connected to oil dampers to understand the response characteristics.</p>","PeriodicalId":42793,"journal":{"name":"Japan Architectural Review","volume":"7 1","pages":""},"PeriodicalIF":0.8000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.12448","citationCount":"0","resultStr":"{\"title\":\"Seismic response characteristics of seismically isolated buildings with dead zone mechanism connected to oil damper\",\"authors\":\"Kazuo Yachiune, Akira Suzuki, Yuta Saito, Masaki Tokuno, Masahito Kobayashi\",\"doi\":\"10.1002/2475-8876.12448\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>In recent years, there has been concern about the occurrence of extreme ground motions that greatly exceed the amplitude levels and durations expected at the conventional design level. Therefore, seismically isolated buildings are required to ensure seismic isolation performance for small earthquakes and suppress the excessive displacement of the seismic isolation layer for extreme ground motions. In this paper, we analyze the seismic response of seismically isolated buildings with the dead zone mechanism connected to oil dampers to understand the response characteristics.</p>\",\"PeriodicalId\":42793,\"journal\":{\"name\":\"Japan Architectural Review\",\"volume\":\"7 1\",\"pages\":\"\"},\"PeriodicalIF\":0.8000,\"publicationDate\":\"2024-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://onlinelibrary.wiley.com/doi/epdf/10.1002/2475-8876.12448\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Japan Architectural Review\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.12448\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"0\",\"JCRName\":\"ARCHITECTURE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Japan Architectural Review","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/2475-8876.12448","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"0","JCRName":"ARCHITECTURE","Score":null,"Total":0}
Seismic response characteristics of seismically isolated buildings with dead zone mechanism connected to oil damper
In recent years, there has been concern about the occurrence of extreme ground motions that greatly exceed the amplitude levels and durations expected at the conventional design level. Therefore, seismically isolated buildings are required to ensure seismic isolation performance for small earthquakes and suppress the excessive displacement of the seismic isolation layer for extreme ground motions. In this paper, we analyze the seismic response of seismically isolated buildings with the dead zone mechanism connected to oil dampers to understand the response characteristics.