Gongcheng Liu, Huimin Wang, Yanlin Han, Chunlong Liu, Man Liang
{"title":"应用自适应蒙特卡洛法对三重同位素稀释质谱法测定人血清中总睾酮的不确定性进行评估。","authors":"Gongcheng Liu, Huimin Wang, Yanlin Han, Chunlong Liu, Man Liang","doi":"10.1007/s00216-024-05380-z","DOIUrl":null,"url":null,"abstract":"<p><p>The measurement uncertainty is a crucial quantitative parameter for assessing the reliability of the result. The study aimed to propose a new budget for uncertainty evaluation of a reference measurement procedure for the determination of total testosterone in human serum. The adaptive Monte Carlo method (aMCM) was used for the propagation of probability distributions assigned to various input quantities to determine the uncertainty of the testosterone concentration. The basic principles of the propagation and the statistical analysis were described based on the experimental results of the quality control serum sample. The analysis of the number of Monte Carlo trials was discussed. The procedure of validation of the GUM uncertainty framework using the aMCM was also provided. The number of Monte Carlo trials was 2.974 × 10<sup>6</sup> when the results had stabilized. The total testosterone concentration was 16.02 nmol/L, and the standard uncertainty was 0.30 nmol/L. The coverage interval at coverage probability of 95% was 15.45 to 16.62 nmol/L, while the probability distribution for testosterone concentration was approximately described by a Gaussian distribution. The validation of results was not passed as the expanded uncertainty result obtained by the aMCM was slightly lower, about 7%, than that by the GUM uncertainty framework with consistent results of the concentration.</p>","PeriodicalId":462,"journal":{"name":"Analytical and Bioanalytical Chemistry","volume":null,"pages":null},"PeriodicalIF":3.8000,"publicationDate":"2024-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525383/pdf/","citationCount":"0","resultStr":"{\"title\":\"Application of the adaptive Monte Carlo method for uncertainty evaluation in the determination of total testosterone in human serum by triple isotope dilution mass spectrometry.\",\"authors\":\"Gongcheng Liu, Huimin Wang, Yanlin Han, Chunlong Liu, Man Liang\",\"doi\":\"10.1007/s00216-024-05380-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The measurement uncertainty is a crucial quantitative parameter for assessing the reliability of the result. The study aimed to propose a new budget for uncertainty evaluation of a reference measurement procedure for the determination of total testosterone in human serum. The adaptive Monte Carlo method (aMCM) was used for the propagation of probability distributions assigned to various input quantities to determine the uncertainty of the testosterone concentration. The basic principles of the propagation and the statistical analysis were described based on the experimental results of the quality control serum sample. The analysis of the number of Monte Carlo trials was discussed. The procedure of validation of the GUM uncertainty framework using the aMCM was also provided. The number of Monte Carlo trials was 2.974 × 10<sup>6</sup> when the results had stabilized. The total testosterone concentration was 16.02 nmol/L, and the standard uncertainty was 0.30 nmol/L. The coverage interval at coverage probability of 95% was 15.45 to 16.62 nmol/L, while the probability distribution for testosterone concentration was approximately described by a Gaussian distribution. The validation of results was not passed as the expanded uncertainty result obtained by the aMCM was slightly lower, about 7%, than that by the GUM uncertainty framework with consistent results of the concentration.</p>\",\"PeriodicalId\":462,\"journal\":{\"name\":\"Analytical and Bioanalytical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2024-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11525383/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Analytical and Bioanalytical Chemistry\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.1007/s00216-024-05380-z\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/6/19 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"BIOCHEMICAL RESEARCH METHODS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical and Bioanalytical Chemistry","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1007/s00216-024-05380-z","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/6/19 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
Application of the adaptive Monte Carlo method for uncertainty evaluation in the determination of total testosterone in human serum by triple isotope dilution mass spectrometry.
The measurement uncertainty is a crucial quantitative parameter for assessing the reliability of the result. The study aimed to propose a new budget for uncertainty evaluation of a reference measurement procedure for the determination of total testosterone in human serum. The adaptive Monte Carlo method (aMCM) was used for the propagation of probability distributions assigned to various input quantities to determine the uncertainty of the testosterone concentration. The basic principles of the propagation and the statistical analysis were described based on the experimental results of the quality control serum sample. The analysis of the number of Monte Carlo trials was discussed. The procedure of validation of the GUM uncertainty framework using the aMCM was also provided. The number of Monte Carlo trials was 2.974 × 106 when the results had stabilized. The total testosterone concentration was 16.02 nmol/L, and the standard uncertainty was 0.30 nmol/L. The coverage interval at coverage probability of 95% was 15.45 to 16.62 nmol/L, while the probability distribution for testosterone concentration was approximately described by a Gaussian distribution. The validation of results was not passed as the expanded uncertainty result obtained by the aMCM was slightly lower, about 7%, than that by the GUM uncertainty framework with consistent results of the concentration.
期刊介绍:
Analytical and Bioanalytical Chemistry’s mission is the rapid publication of excellent and high-impact research articles on fundamental and applied topics of analytical and bioanalytical measurement science. Its scope is broad, and ranges from novel measurement platforms and their characterization to multidisciplinary approaches that effectively address important scientific problems. The Editors encourage submissions presenting innovative analytical research in concept, instrumentation, methods, and/or applications, including: mass spectrometry, spectroscopy, and electroanalysis; advanced separations; analytical strategies in “-omics” and imaging, bioanalysis, and sampling; miniaturized devices, medical diagnostics, sensors; analytical characterization of nano- and biomaterials; chemometrics and advanced data analysis.