{"title":"约束膨胀混凝土在干燥条件下的透气性变化:膨胀应变的贡献","authors":"Adhitya Leonard Wijaya,&nbsp;Kenichiro Nakarai","doi":"10.1617/s11527-024-02401-2","DOIUrl":null,"url":null,"abstract":"<div><p>Restraining the expansion of expansive concrete with embedded rebars can exert chemical prestressing, which may affect the durability of concrete structures. This study aims to investigate the durability performance of expansive concrete by understanding the mechanism of air permeability changes while considering the variations in reinforcement arrangements and concrete dimensions. The Torrent’s air permeability test was used to non-destructively evaluate the disparity in air permeability changes of expansive and normal concrete during the drying processes from 28 to 182 days. Additionally, expansive strain changes were continuously monitored to investigate chemical prestress. The experimental test results suggest the immense effect of the change in expansive strain on the air permeability of concrete. This study proposes that the change in microstructure owing to the loss of expansive strain may cause an increase in air permeability. The loss of expansive strain is a distinguished feature that differentiates the mechanism of air permeability changes in expansive and normal concrete. These findings suggest the possible improvement in the durability performance of expansive concrete in cases where the loss of its expansive strain can be controlled.</p></div>","PeriodicalId":691,"journal":{"name":"Materials and Structures","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.1617/s11527-024-02401-2.pdf","citationCount":"0","resultStr":"{\"title\":\"Changes in air permeability of restrained expansive concrete under drying condition: contribution of expansive strain\",\"authors\":\"Adhitya Leonard Wijaya,&nbsp;Kenichiro Nakarai\",\"doi\":\"10.1617/s11527-024-02401-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Restraining the expansion of expansive concrete with embedded rebars can exert chemical prestressing, which may affect the durability of concrete structures. This study aims to investigate the durability performance of expansive concrete by understanding the mechanism of air permeability changes while considering the variations in reinforcement arrangements and concrete dimensions. The Torrent’s air permeability test was used to non-destructively evaluate the disparity in air permeability changes of expansive and normal concrete during the drying processes from 28 to 182 days. Additionally, expansive strain changes were continuously monitored to investigate chemical prestress. The experimental test results suggest the immense effect of the change in expansive strain on the air permeability of concrete. This study proposes that the change in microstructure owing to the loss of expansive strain may cause an increase in air permeability. The loss of expansive strain is a distinguished feature that differentiates the mechanism of air permeability changes in expansive and normal concrete. These findings suggest the possible improvement in the durability performance of expansive concrete in cases where the loss of its expansive strain can be controlled.</p></div>\",\"PeriodicalId\":691,\"journal\":{\"name\":\"Materials and Structures\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2024-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.1617/s11527-024-02401-2.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Materials and Structures\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://link.springer.com/article/10.1617/s11527-024-02401-2\",\"RegionNum\":3,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Materials and Structures","FirstCategoryId":"5","ListUrlMain":"https://link.springer.com/article/10.1617/s11527-024-02401-2","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

用预埋钢筋抑制膨胀混凝土的膨胀可以产生化学预应力,这可能会影响混凝土结构的耐久性。本研究旨在通过了解透气性变化的机理,同时考虑钢筋布置和混凝土尺寸的变化,来研究膨胀混凝土的耐久性能。在 28 天至 182 天的干燥过程中,采用 Torrent 的透气性测试对膨胀性混凝土和普通混凝土的透气性变化差异进行了非破坏性评估。此外,还对膨胀应变变化进行了连续监测,以研究化学预应力。实验结果表明,膨胀应变的变化对混凝土的透气性影响巨大。本研究认为,膨胀应变损失导致的微观结构变化可能会增加透气性。膨胀应变的损失是区分膨胀混凝土和普通混凝土透气性变化机制的一个显著特征。这些发现表明,在可以控制膨胀应变损失的情况下,膨胀混凝土的耐久性能可能会得到改善。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Changes in air permeability of restrained expansive concrete under drying condition: contribution of expansive strain

Changes in air permeability of restrained expansive concrete under drying condition: contribution of expansive strain

Restraining the expansion of expansive concrete with embedded rebars can exert chemical prestressing, which may affect the durability of concrete structures. This study aims to investigate the durability performance of expansive concrete by understanding the mechanism of air permeability changes while considering the variations in reinforcement arrangements and concrete dimensions. The Torrent’s air permeability test was used to non-destructively evaluate the disparity in air permeability changes of expansive and normal concrete during the drying processes from 28 to 182 days. Additionally, expansive strain changes were continuously monitored to investigate chemical prestress. The experimental test results suggest the immense effect of the change in expansive strain on the air permeability of concrete. This study proposes that the change in microstructure owing to the loss of expansive strain may cause an increase in air permeability. The loss of expansive strain is a distinguished feature that differentiates the mechanism of air permeability changes in expansive and normal concrete. These findings suggest the possible improvement in the durability performance of expansive concrete in cases where the loss of its expansive strain can be controlled.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Materials and Structures
Materials and Structures 工程技术-材料科学:综合
CiteScore
6.40
自引率
7.90%
发文量
222
审稿时长
5.9 months
期刊介绍: Materials and Structures, the flagship publication of the International Union of Laboratories and Experts in Construction Materials, Systems and Structures (RILEM), provides a unique international and interdisciplinary forum for new research findings on the performance of construction materials. A leader in cutting-edge research, the journal is dedicated to the publication of high quality papers examining the fundamental properties of building materials, their characterization and processing techniques, modeling, standardization of test methods, and the application of research results in building and civil engineering. Materials and Structures also publishes comprehensive reports prepared by the RILEM’s technical committees.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信