{"title":"改善低收入和中等收入国家第一和第二产程的管理","authors":"G Justus Hofmeyr , Badani Moreri-Ntshabele , Zahida Qureshi , Ndiwo Memo , Sarah Hanson , Elani Muller , Mandisa Singata-Madliki","doi":"10.1016/j.bpobgyn.2024.102517","DOIUrl":null,"url":null,"abstract":"<div><p>Labour care must balance aspirations of parents with vigilance for unanticipated calamities. The ‘on-site midwife-led primary care birth unit’ facilitates this.</p><p>The World Health Organization have replaced the traditional partograph with the ‘Labour Care Guide’. An implementation project in Botswana included the mnemonic COPE: Companion, Oral fluids, Pain relief and Eliminate the supine position. The Parto-Ma project in Tanzania used guidelines, training and support to improve childbirth outcomes. We list labour practices supported by recent evidence, and highlight new developments. Foetal macrosomia increases risk but mistaken diagnosis increases caesarean births. Obstructed labour is a complex clinical diagnosis, and is difficult to predict. For shoulder dystocia prioritise delivery of the posterior shoulder, facilitated if needed by posterior axilla sling traction. ‘Extended balloon labour induction’ with two or three Foley catheters side by side, may reduce risks associated with uterine stimulants. Bedside ultrasound may facilitate the diagnosis of cephalic malpositions and malpresentations.</p></div>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2024-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.sciencedirect.com/science/article/pii/S1521693424000634/pdfft?md5=405ffdf9c4f99dbd5404d800e82d7e1b&pid=1-s2.0-S1521693424000634-main.pdf","citationCount":"0","resultStr":"{\"title\":\"Improving management of first and second stages of labour in low- and middle-income countries\",\"authors\":\"G Justus Hofmeyr , Badani Moreri-Ntshabele , Zahida Qureshi , Ndiwo Memo , Sarah Hanson , Elani Muller , Mandisa Singata-Madliki\",\"doi\":\"10.1016/j.bpobgyn.2024.102517\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Labour care must balance aspirations of parents with vigilance for unanticipated calamities. The ‘on-site midwife-led primary care birth unit’ facilitates this.</p><p>The World Health Organization have replaced the traditional partograph with the ‘Labour Care Guide’. An implementation project in Botswana included the mnemonic COPE: Companion, Oral fluids, Pain relief and Eliminate the supine position. The Parto-Ma project in Tanzania used guidelines, training and support to improve childbirth outcomes. We list labour practices supported by recent evidence, and highlight new developments. Foetal macrosomia increases risk but mistaken diagnosis increases caesarean births. Obstructed labour is a complex clinical diagnosis, and is difficult to predict. For shoulder dystocia prioritise delivery of the posterior shoulder, facilitated if needed by posterior axilla sling traction. ‘Extended balloon labour induction’ with two or three Foley catheters side by side, may reduce risks associated with uterine stimulants. Bedside ultrasound may facilitate the diagnosis of cephalic malpositions and malpresentations.</p></div>\",\"PeriodicalId\":3,\"journal\":{\"name\":\"ACS Applied Electronic Materials\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.3000,\"publicationDate\":\"2024-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.sciencedirect.com/science/article/pii/S1521693424000634/pdfft?md5=405ffdf9c4f99dbd5404d800e82d7e1b&pid=1-s2.0-S1521693424000634-main.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Applied Electronic Materials\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S1521693424000634\",\"RegionNum\":3,\"RegionCategory\":\"材料科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, ELECTRICAL & ELECTRONIC\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1521693424000634","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
Improving management of first and second stages of labour in low- and middle-income countries
Labour care must balance aspirations of parents with vigilance for unanticipated calamities. The ‘on-site midwife-led primary care birth unit’ facilitates this.
The World Health Organization have replaced the traditional partograph with the ‘Labour Care Guide’. An implementation project in Botswana included the mnemonic COPE: Companion, Oral fluids, Pain relief and Eliminate the supine position. The Parto-Ma project in Tanzania used guidelines, training and support to improve childbirth outcomes. We list labour practices supported by recent evidence, and highlight new developments. Foetal macrosomia increases risk but mistaken diagnosis increases caesarean births. Obstructed labour is a complex clinical diagnosis, and is difficult to predict. For shoulder dystocia prioritise delivery of the posterior shoulder, facilitated if needed by posterior axilla sling traction. ‘Extended balloon labour induction’ with two or three Foley catheters side by side, may reduce risks associated with uterine stimulants. Bedside ultrasound may facilitate the diagnosis of cephalic malpositions and malpresentations.