Yuetong Sun , Lin Zhou , Fankai Meng , Zhipeng Wang
{"title":"焦平面红外探测器四级热电冷却器的性能分析","authors":"Yuetong Sun , Lin Zhou , Fankai Meng , Zhipeng Wang","doi":"10.1016/j.ijrefrig.2024.06.011","DOIUrl":null,"url":null,"abstract":"<div><p>A cooler provides a low-temperature working environment for refrigerated infrared detection chips and is an indispensable component in infrared detectors that ensures their smooth operation. In this paper, a thermodynamic model of a heat-pipe-type four-stage thermoelectric cooler with a large temperature difference applied to a focal plane infrared detector is constructed. The heat leakage of the detector is calculated using the model. The performance indexes of the coordination performance coefficient and module utilization coefficient are used to unify the cooling capacity and economic performance of the device. The impression of the working current, heat pipe parameters, and cross-sectional area of the thermoelectric leg on the performance of cooler are analyzed. A Pareto optimal solution is obtained using an NSGA-II algorithm and TOPSIS decision. A low cooling temperature is obtained using a multistage thermoelectric cooler to achieve a large cooling temperature difference. When the working current is 5.65 A and the cross-sectional area is 4.5 mm<sup>2</sup>, the maximum cooling temperature difference reaches 110.6 °C, and the lowest cooling temperature reaches -83.6 °C. When the working temperature of the detector is -60 °C, the current and cross-sectional area corresponding to the optimal solution of cooling capacity-COP-power consumption are 1.51 A and 2.74 mm<sup>2</sup>, respectively.</p></div>","PeriodicalId":14274,"journal":{"name":"International Journal of Refrigeration-revue Internationale Du Froid","volume":null,"pages":null},"PeriodicalIF":3.5000,"publicationDate":"2024-06-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Performance analysis of four-stage thermoelectric cooler for focal plane infrared detectors\",\"authors\":\"Yuetong Sun , Lin Zhou , Fankai Meng , Zhipeng Wang\",\"doi\":\"10.1016/j.ijrefrig.2024.06.011\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A cooler provides a low-temperature working environment for refrigerated infrared detection chips and is an indispensable component in infrared detectors that ensures their smooth operation. In this paper, a thermodynamic model of a heat-pipe-type four-stage thermoelectric cooler with a large temperature difference applied to a focal plane infrared detector is constructed. The heat leakage of the detector is calculated using the model. The performance indexes of the coordination performance coefficient and module utilization coefficient are used to unify the cooling capacity and economic performance of the device. The impression of the working current, heat pipe parameters, and cross-sectional area of the thermoelectric leg on the performance of cooler are analyzed. A Pareto optimal solution is obtained using an NSGA-II algorithm and TOPSIS decision. A low cooling temperature is obtained using a multistage thermoelectric cooler to achieve a large cooling temperature difference. When the working current is 5.65 A and the cross-sectional area is 4.5 mm<sup>2</sup>, the maximum cooling temperature difference reaches 110.6 °C, and the lowest cooling temperature reaches -83.6 °C. When the working temperature of the detector is -60 °C, the current and cross-sectional area corresponding to the optimal solution of cooling capacity-COP-power consumption are 1.51 A and 2.74 mm<sup>2</sup>, respectively.</p></div>\",\"PeriodicalId\":14274,\"journal\":{\"name\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.5000,\"publicationDate\":\"2024-06-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Refrigeration-revue Internationale Du Froid\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0140700724002147\",\"RegionNum\":2,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"ENGINEERING, MECHANICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Refrigeration-revue Internationale Du Froid","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0140700724002147","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"ENGINEERING, MECHANICAL","Score":null,"Total":0}
Performance analysis of four-stage thermoelectric cooler for focal plane infrared detectors
A cooler provides a low-temperature working environment for refrigerated infrared detection chips and is an indispensable component in infrared detectors that ensures their smooth operation. In this paper, a thermodynamic model of a heat-pipe-type four-stage thermoelectric cooler with a large temperature difference applied to a focal plane infrared detector is constructed. The heat leakage of the detector is calculated using the model. The performance indexes of the coordination performance coefficient and module utilization coefficient are used to unify the cooling capacity and economic performance of the device. The impression of the working current, heat pipe parameters, and cross-sectional area of the thermoelectric leg on the performance of cooler are analyzed. A Pareto optimal solution is obtained using an NSGA-II algorithm and TOPSIS decision. A low cooling temperature is obtained using a multistage thermoelectric cooler to achieve a large cooling temperature difference. When the working current is 5.65 A and the cross-sectional area is 4.5 mm2, the maximum cooling temperature difference reaches 110.6 °C, and the lowest cooling temperature reaches -83.6 °C. When the working temperature of the detector is -60 °C, the current and cross-sectional area corresponding to the optimal solution of cooling capacity-COP-power consumption are 1.51 A and 2.74 mm2, respectively.
期刊介绍:
The International Journal of Refrigeration is published for the International Institute of Refrigeration (IIR) by Elsevier. It is essential reading for all those wishing to keep abreast of research and industrial news in refrigeration, air conditioning and associated fields. This is particularly important in these times of rapid introduction of alternative refrigerants and the emergence of new technology. The journal has published special issues on alternative refrigerants and novel topics in the field of boiling, condensation, heat pumps, food refrigeration, carbon dioxide, ammonia, hydrocarbons, magnetic refrigeration at room temperature, sorptive cooling, phase change materials and slurries, ejector technology, compressors, and solar cooling.
As well as original research papers the International Journal of Refrigeration also includes review articles, papers presented at IIR conferences, short reports and letters describing preliminary results and experimental details, and letters to the Editor on recent areas of discussion and controversy. Other features include forthcoming events, conference reports and book reviews.
Papers are published in either English or French with the IIR news section in both languages.