工业企业电气设备的热成像控制

A. Shpiganovich, A. Shpiganovich, A. R. Petrov, E. Gracheva
{"title":"工业企业电气设备的热成像控制","authors":"A. Shpiganovich, A. Shpiganovich, A. R. Petrov, E. Gracheva","doi":"10.30724/1998-9903-2024-26-2-68-77","DOIUrl":null,"url":null,"abstract":"RELEVANCE. Thermal imaging control is used to monitor the technical condition of electrical equipment, as well as contacts and contact connections of switching devices, which allows to increase the efficiency of work.OBJECT. Timely detection of defects of contacts and contact connections of low-voltage switching devices to prevent emergencies.METHODS. Determination and control of technical condition of electrical equipment, contacts and contact connections of apparatuses in real time by means of indicators and thermal imaging control.RESULTS. The values of contact heating temperatures from material and type of contact connections were analysed. The criteria for estimation of the state of contacts of switching devices with the help of indicators of their state have been determined. The optimum values of loading coefficients of the circuit breaker in moulded case VA04 and contactors KMI and KTI are obtained. Emergency cases at the industrial object are shown, which prove the necessity of application of indicators and thermal imaging control as one of the tools of automation of technical condition control of low-voltage electrical equipment.CONCLUSIONS. The offered noncontact method of estimation and control of technical condition of electrical equipment, contacts and contact connections of devices in real time with the help of indicators and thermal imaging control allows both to receive data in real time mode and to increase inter-repair periods for power equipment and to increase reliability of operation of the whole system.","PeriodicalId":222237,"journal":{"name":"Power engineering: research, equipment, technology","volume":"124 4","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2024-06-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Thermal imaging control of electrical equipment of industrial enterprises\",\"authors\":\"A. Shpiganovich, A. Shpiganovich, A. R. Petrov, E. Gracheva\",\"doi\":\"10.30724/1998-9903-2024-26-2-68-77\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"RELEVANCE. Thermal imaging control is used to monitor the technical condition of electrical equipment, as well as contacts and contact connections of switching devices, which allows to increase the efficiency of work.OBJECT. Timely detection of defects of contacts and contact connections of low-voltage switching devices to prevent emergencies.METHODS. Determination and control of technical condition of electrical equipment, contacts and contact connections of apparatuses in real time by means of indicators and thermal imaging control.RESULTS. The values of contact heating temperatures from material and type of contact connections were analysed. The criteria for estimation of the state of contacts of switching devices with the help of indicators of their state have been determined. The optimum values of loading coefficients of the circuit breaker in moulded case VA04 and contactors KMI and KTI are obtained. Emergency cases at the industrial object are shown, which prove the necessity of application of indicators and thermal imaging control as one of the tools of automation of technical condition control of low-voltage electrical equipment.CONCLUSIONS. The offered noncontact method of estimation and control of technical condition of electrical equipment, contacts and contact connections of devices in real time with the help of indicators and thermal imaging control allows both to receive data in real time mode and to increase inter-repair periods for power equipment and to increase reliability of operation of the whole system.\",\"PeriodicalId\":222237,\"journal\":{\"name\":\"Power engineering: research, equipment, technology\",\"volume\":\"124 4\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2024-06-03\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Power engineering: research, equipment, technology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.30724/1998-9903-2024-26-2-68-77\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Power engineering: research, equipment, technology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.30724/1998-9903-2024-26-2-68-77","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

意义。热成像控制用于监测电气设备以及开关设备触头和触头连接的技术状况,从而提高工作效率。及时发现低压开关设备触头和触头连接的缺陷,防止紧急情况的发生。 方法:通过指示器和热成像控制,实时确定和控制电气设备、设备触头和触头连接的技术状态。分析了接触加热温度值与接触连接材料和类型的关系。在开关设备触点状态指示器的帮助下,确定了开关设备触点状态的估算标准。获得了模制外壳 VA04 断路器以及 KMI 和 KTI 接触器负载系数的最佳值。展示了工业对象的紧急案例,证明了作为低压电气设备技术状态控制自动化工具之一的指示器和热成像控制应用的必要性。在指示器和热成像控制的帮助下,所提供的对电气设备、触点和设备接触连接的技术状态进行实时评估和控制的非接触式方法,既能以实时模式接收数据,又能延长电力设备的维修间隔期,提高整个系统的运行可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal imaging control of electrical equipment of industrial enterprises
RELEVANCE. Thermal imaging control is used to monitor the technical condition of electrical equipment, as well as contacts and contact connections of switching devices, which allows to increase the efficiency of work.OBJECT. Timely detection of defects of contacts and contact connections of low-voltage switching devices to prevent emergencies.METHODS. Determination and control of technical condition of electrical equipment, contacts and contact connections of apparatuses in real time by means of indicators and thermal imaging control.RESULTS. The values of contact heating temperatures from material and type of contact connections were analysed. The criteria for estimation of the state of contacts of switching devices with the help of indicators of their state have been determined. The optimum values of loading coefficients of the circuit breaker in moulded case VA04 and contactors KMI and KTI are obtained. Emergency cases at the industrial object are shown, which prove the necessity of application of indicators and thermal imaging control as one of the tools of automation of technical condition control of low-voltage electrical equipment.CONCLUSIONS. The offered noncontact method of estimation and control of technical condition of electrical equipment, contacts and contact connections of devices in real time with the help of indicators and thermal imaging control allows both to receive data in real time mode and to increase inter-repair periods for power equipment and to increase reliability of operation of the whole system.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信