{"title":"基于智能手机的优化比色检测方法,用于评估不同冲泡条件下茶叶提取物中的氟释放量","authors":"Le-Thi Anh-Dao, Do Minh-Huy, Nguyen Thu-Huong, Vo-Thi Tuong-Thu, Nguyen-Thi Kim-Sinh, Nguyen Thanh-Nho, Nguyen Cong-Hau","doi":"10.1007/s13738-024-03057-z","DOIUrl":null,"url":null,"abstract":"<p>A smartphone-based colorimetric detection method was optimized for measuring the fluoride content in tea extracts using zirconium-xylenol orange reagent. The images of the formed color complex in the presence of fluoride were captured and analyzed their color components through the RGB (Red, Green, Blue) vector values. To maintain the capturing conditions, a colorimetric box (150 × 70 × 90 mm) was self-designed by optimizing the smartphone camera-sample holder/cuvette distance and inside brightness. The calibration curve was constructed from 0.5 to 25 mg/L with the goodness of linearity (<i>R</i><sup>2</sup> > 0.995). Favorable repeatability and reproducibility were obtained (RSD<sub>r</sub> = 5.01% and RSD<sub>R</sub> = 5.02%), according to the Appendix F of AOAC (2016). UV–Vis and F ion-selective electrode were simultaneously conducted as reference methods for the developed smartphone-based method, demonstrating comparable fluoride content results in tea extracts obtained from these methods. Using 2.5 g tea brewed in 100 mL of deionized water at 90 °C for 60 min, a descending fluoride content order was achieved: black tea (3.31–3.85 mg/L) > oolong tea (2.38–2.65 mg/L) > green tea (2.25–2.97 mg/L) > white tea (2.28–2.31 mg/L). The smartphone-based method was also applied to evaluate the effects of different brewing conditions on the fluoride content in tea extracts, indicating the higher brewing temperature and prolonged time could accelerate the release of fluoride in tea extracts. This study provides a quality control tool for tea consumers and manufacturers as well as contributes to enrich the applications of smartphone-based methods in the food sections, especially for Vietnam with the diversity of agricultural products.</p>","PeriodicalId":676,"journal":{"name":"Journal of the Iranian Chemical Society","volume":"21 8","pages":"2137 - 2146"},"PeriodicalIF":2.2000,"publicationDate":"2024-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"An optimized smartphone-based colorimetric detection method for evaluating the fluoride released in tea extracts from different brewing conditions\",\"authors\":\"Le-Thi Anh-Dao, Do Minh-Huy, Nguyen Thu-Huong, Vo-Thi Tuong-Thu, Nguyen-Thi Kim-Sinh, Nguyen Thanh-Nho, Nguyen Cong-Hau\",\"doi\":\"10.1007/s13738-024-03057-z\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>A smartphone-based colorimetric detection method was optimized for measuring the fluoride content in tea extracts using zirconium-xylenol orange reagent. The images of the formed color complex in the presence of fluoride were captured and analyzed their color components through the RGB (Red, Green, Blue) vector values. To maintain the capturing conditions, a colorimetric box (150 × 70 × 90 mm) was self-designed by optimizing the smartphone camera-sample holder/cuvette distance and inside brightness. The calibration curve was constructed from 0.5 to 25 mg/L with the goodness of linearity (<i>R</i><sup>2</sup> > 0.995). Favorable repeatability and reproducibility were obtained (RSD<sub>r</sub> = 5.01% and RSD<sub>R</sub> = 5.02%), according to the Appendix F of AOAC (2016). UV–Vis and F ion-selective electrode were simultaneously conducted as reference methods for the developed smartphone-based method, demonstrating comparable fluoride content results in tea extracts obtained from these methods. Using 2.5 g tea brewed in 100 mL of deionized water at 90 °C for 60 min, a descending fluoride content order was achieved: black tea (3.31–3.85 mg/L) > oolong tea (2.38–2.65 mg/L) > green tea (2.25–2.97 mg/L) > white tea (2.28–2.31 mg/L). The smartphone-based method was also applied to evaluate the effects of different brewing conditions on the fluoride content in tea extracts, indicating the higher brewing temperature and prolonged time could accelerate the release of fluoride in tea extracts. This study provides a quality control tool for tea consumers and manufacturers as well as contributes to enrich the applications of smartphone-based methods in the food sections, especially for Vietnam with the diversity of agricultural products.</p>\",\"PeriodicalId\":676,\"journal\":{\"name\":\"Journal of the Iranian Chemical Society\",\"volume\":\"21 8\",\"pages\":\"2137 - 2146\"},\"PeriodicalIF\":2.2000,\"publicationDate\":\"2024-06-13\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Iranian Chemical Society\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://link.springer.com/article/10.1007/s13738-024-03057-z\",\"RegionNum\":4,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CHEMISTRY, MULTIDISCIPLINARY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Iranian Chemical Society","FirstCategoryId":"92","ListUrlMain":"https://link.springer.com/article/10.1007/s13738-024-03057-z","RegionNum":4,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
An optimized smartphone-based colorimetric detection method for evaluating the fluoride released in tea extracts from different brewing conditions
A smartphone-based colorimetric detection method was optimized for measuring the fluoride content in tea extracts using zirconium-xylenol orange reagent. The images of the formed color complex in the presence of fluoride were captured and analyzed their color components through the RGB (Red, Green, Blue) vector values. To maintain the capturing conditions, a colorimetric box (150 × 70 × 90 mm) was self-designed by optimizing the smartphone camera-sample holder/cuvette distance and inside brightness. The calibration curve was constructed from 0.5 to 25 mg/L with the goodness of linearity (R2 > 0.995). Favorable repeatability and reproducibility were obtained (RSDr = 5.01% and RSDR = 5.02%), according to the Appendix F of AOAC (2016). UV–Vis and F ion-selective electrode were simultaneously conducted as reference methods for the developed smartphone-based method, demonstrating comparable fluoride content results in tea extracts obtained from these methods. Using 2.5 g tea brewed in 100 mL of deionized water at 90 °C for 60 min, a descending fluoride content order was achieved: black tea (3.31–3.85 mg/L) > oolong tea (2.38–2.65 mg/L) > green tea (2.25–2.97 mg/L) > white tea (2.28–2.31 mg/L). The smartphone-based method was also applied to evaluate the effects of different brewing conditions on the fluoride content in tea extracts, indicating the higher brewing temperature and prolonged time could accelerate the release of fluoride in tea extracts. This study provides a quality control tool for tea consumers and manufacturers as well as contributes to enrich the applications of smartphone-based methods in the food sections, especially for Vietnam with the diversity of agricultural products.
期刊介绍:
JICS is an international journal covering general fields of chemistry. JICS welcomes high quality original papers in English dealing with experimental, theoretical and applied research related to all branches of chemistry. These include the fields of analytical, inorganic, organic and physical chemistry as well as the chemical biology area. Review articles discussing specific areas of chemistry of current chemical or biological importance are also published. JICS ensures visibility of your research results to a worldwide audience in science. You are kindly invited to submit your manuscript to the Editor-in-Chief or Regional Editor. All contributions in the form of original papers or short communications will be peer reviewed and published free of charge after acceptance.