Umar Hussain, Alessandra Campobasso, Muhammad Noman, Shamsul Alam, Rida Mujeeb, Sofia Shehzad, Spyridon N Papageorgiou
{"title":"固定矫治器正畸治疗期间弹性和钢制结扎对牙周健康的影响:系统综述和荟萃分析。","authors":"Umar Hussain, Alessandra Campobasso, Muhammad Noman, Shamsul Alam, Rida Mujeeb, Sofia Shehzad, Spyridon N Papageorgiou","doi":"10.1186/s40510-024-00520-8","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health.</p><p><strong>Aim: </strong>This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances.</p><p><strong>Methods: </strong>Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach.</p><p><strong>Results: </strong>A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias.</p><p><strong>Conclusions: </strong>Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load.</p><p><strong>Registration: </strong>PROSPERO (CRD42023444383).</p>","PeriodicalId":56071,"journal":{"name":"Progress in Orthodontics","volume":"25 1","pages":"24"},"PeriodicalIF":4.8000,"publicationDate":"2024-06-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11180646/pdf/","citationCount":"0","resultStr":"{\"title\":\"Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis.\",\"authors\":\"Umar Hussain, Alessandra Campobasso, Muhammad Noman, Shamsul Alam, Rida Mujeeb, Sofia Shehzad, Spyridon N Papageorgiou\",\"doi\":\"10.1186/s40510-024-00520-8\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health.</p><p><strong>Aim: </strong>This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances.</p><p><strong>Methods: </strong>Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach.</p><p><strong>Results: </strong>A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias.</p><p><strong>Conclusions: </strong>Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load.</p><p><strong>Registration: </strong>PROSPERO (CRD42023444383).</p>\",\"PeriodicalId\":56071,\"journal\":{\"name\":\"Progress in Orthodontics\",\"volume\":\"25 1\",\"pages\":\"24\"},\"PeriodicalIF\":4.8000,\"publicationDate\":\"2024-06-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC11180646/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Progress in Orthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s40510-024-00520-8\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Dentistry\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Progress in Orthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s40510-024-00520-8","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 0
摘要
导言:目的:本系统综述比较了用于正畸固定矫治器的弹性结扎带和钢制结扎带对牙周的影响:在 7 个数据库(MEDLINE、Scopus、Web of Science、Embase、Cochrane 系统综述数据库、Cochrane 对照试验中央登记册和虚拟健康图书馆)中对截至 2023 年 7 月的随机/非随机人体临床研究进行了检索,比较了固定矫治器治疗过程中的两种结扎方法。在重复选择研究、提取数据并使用偏倚风险(RoB)2 或干预措施非随机研究中的偏倚风险(ROBINS-I)工具进行偏倚风险评估后,对平均差(MD)或标准化平均差(SMD)及其 95% 置信区间(CI)进行随机效应荟萃分析,然后使用推荐、评估、发展和评价分级(GRADE)方法对现有证据的确定性进行评估:共纳入 11 项研究(3 项随机/8 项非随机),354 名患者(平均年龄 14.7 岁,42% 为男性)。斑块指数(5 项研究;SMD = 0.48;95% CI = -0.03 至 1.00;P = 0.07)、牙龈指数(2 项研究;MD = 0.01;95% CI = -0.14 至 0.16; P = 0.89)、探诊袋深度(2 项研究;MD = 0; 95% CI = -0.17 to 0.16; P = 0.97)或变异链球菌计数(4 项研究;SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21)。弹性结扎与细菌总数的中度增加有关(3 项研究;SMD = 0.43;95% CI = 0.10 至 0.76;P = 0.03)。由于纳入了偏倚风险较高的非随机研究,这些估计值的可信度都较低:现有的低质量证据表明,结扎方法似乎不会影响固定治疗期间的牙周健康,即使弹性结扎与细菌负荷的适度增加有关:prospero(CRD42023444383)。
Influence of elastomeric and steel ligatures on periodontal health during fixed appliance orthodontic treatment: a systematic review and meta-analysis.
Introduction: Metallic and elastomeric ligatures are widely used in orthodontics to secure the archwire within the bracket slots, but elastomeric ligatures have traditionally been associated with increased microbial colonization, which could adversely affect periodontal health.
Aim: This systematic review compares the periodontal effects of elastomeric and steel ligatures used for orthodontic fixed appliances.
Methods: Unrestricted literature search of 7 databases (MEDLINE, Scopus, Web of Science, Embase, Cochrane Database of Systematic Reviews, Cochrane Central Register of Controlled Trials, and Virtual Health Library) up to July 2023 were performed for randomized / non-randomized clinical studies on humans comparing the two ligation methods during fixed-appliance therapy. After duplicate study selection, data extraction, and risk-of-bias assessment with the Risk of Bias (RoB) 2 or the Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) tool, random-effects meta-analyses of Mean Differences (MD) or Standardized Mean Differences (SMD) and their 95% confidence intervals (CIs) were carried out, followed by assessment of certainty of existing evidence with the Grades of Recommendation, Assessment, Development, and Evaluation (GRADE) approach.
Results: A total of 11 studies (3 randomized / 8 non-randomized) with 354 patients (mean age 14.7 years and 42% male) were included. No statistically significant differences were seen for plaque index (5 studies; SMD = 0.48; 95% CI = -0.03 to 1.00; P = 0.07), gingival index (2 studies; MD = 0.01; 95% CI = -0.14 to 0.16; P = 0.89), probing pocket depth (2 studies; MD = 0; 95% CI = -0.17 to 0.16; P = 0.97), or Streptococcus mutans counts (4 studies; SMD = 0.40; 95% CI=-0.41 to 1.20; P = 0.21). Elastomeric ligatures were associated with moderately increased total bacterial load (3 studies; SMD = 0.43; 95% CI = 0.10 to 0.76; P = 0.03). Confidence in these estimates was low in all instances due to the inclusion of non-randomized studies with high risk of bias.
Conclusions: Existing low quality evidence indicates that ligature method does not seem to influence the periodontal health during fixed treatment, even if elastomeric ligatures are associated with a moderate increase of bacterial load.
期刊介绍:
Progress in Orthodontics is a fully open access, international journal owned by the Italian Society of Orthodontics and published under the brand SpringerOpen. The Society is currently covering all publication costs so there are no article processing charges for authors.
It is a premier journal of international scope that fosters orthodontic research, including both basic research and development of innovative clinical techniques, with an emphasis on the following areas:
• Mechanisms to improve orthodontics
• Clinical studies and control animal studies
• Orthodontics and genetics, genomics
• Temporomandibular joint (TMJ) control clinical trials
• Efficacy of orthodontic appliances and animal models
• Systematic reviews and meta analyses
• Mechanisms to speed orthodontic treatment
Progress in Orthodontics will consider for publication only meritorious and original contributions. These may be:
• Original articles reporting the findings of clinical trials, clinically relevant basic scientific investigations, or novel therapeutic or diagnostic systems
• Review articles on current topics
• Articles on novel techniques and clinical tools
• Articles of contemporary interest